ML18302A411
ML18302A411 | |
Person / Time | |
---|---|
Site: | NuScale |
Issue date: | 10/29/2018 |
From: | Rad Z NuScale |
To: | Document Control Desk, Office of New Reactors |
References | |
RAIO-1018-62357 | |
Download: ML18302A411 (7) | |
Text
RAIO-1018-62357 October 29, 2018 Docket No.52-048 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738
SUBJECT:
NuScale Power, LLC Response to NRC Request for Additional Information No.
504 (eRAI No. 9605) on the NuScale Design Certification Application
REFERENCE:
U.S. Nuclear Regulatory Commission, "Request for Additional Information No.
504 (eRAI No. 9605)," dated September 18, 2018 The purpose of this letter is to provide the NuScale Power, LLC (NuScale) response to the referenced NRC Request for Additional Information (RAI).
The Enclosure to this letter contains NuScale's response to the following RAI Question from NRC eRAI No. 9605:
- 03.05.01.03-1 This letter and the enclosed response make no new regulatory commitments and no revisions to any existing regulatory commitments.
If you have any questions on this response, please contact Carrie Fosaaen at 541-452-7126 or at cfosaaen@nuscalepower.com.
Sincerely,
~ ~
Zackary W. Rad Director, Regulatory Affairs NuScale Power, LLC Distribution: Gregory Cranston, NRC, OWFN-8G9A Samuel Lee, NRC, OWFN-8G9A Marieliz Vera, NRC, OWFN-8G9A Enclosure 1: NuScale Response to NRC Request for Additional Information eRAI No. 9605 NuScale Power, LLC 1100 NE Circle Blvd. , Suite 200 Corvalis, Oregon 97330 , Office: 541.360.0500 , Fax: 541.207.3928 www.nuscalepower.com
NuScale Response to NRC Request for Additional Information eRAI No. 9605 NuScale Power, LLC 1100 NE Circle Blvd., Suite 200 Corvalis, Oregon 97330, Office: 541.360.0500, Fax: 541.207.3928 www.nuscalepower.com
Response to Request for Additional Information Docket No.52-048 eRAI No.: 9605 Date of RAI Issue: 09/18/2018 NRC Question No.: 03.05.01.03-1 Title 10 of the Code of Federal Regulations (10 CFR) Part 50, Appendix A, General Design Criterion (GDC) 4, "Environmental and Dynamic Effects Design Bases," states in part that structures, systems, and components (SCCs) important to safety shall be appropriately protected against environmental and dynamic effects, including the effects of missiles, that may result from equipment failure. In order for the staff to determine whether the NuScale design meets these criteria with regard to effects of turbine missiles on components important to safety, the staff is requesting the following information.
The applicant in its letter dated June 25, 2018, proposed to revise the NuScale FSAR to use barriers in lieu of turbine rotor integrity and turbine probability as the basis for justifying adequate protection from turbine missiles. Part of the FSAR revision deleted COL Item 3.5-2 which stated that a COL applicant that references the NuScale design will address the effects of turbine missiles from nearby or co-located facilities. However, per Section C of RG 1.115, "Protection Against Turbine Missiles," Revision 2, states that plants can protect essential SSCs against turbine missiles by using barriers or turbine missile probability taking into account all present and future nuclear and nonnuclear units at the site. Therefore, the use of barriers does not preclude evaluation of turbine missiles from nearby facilities, and whether they are bounded by the analysis performed for the barriers. The staff found the inclusion of the original COL Item 3.5-2 necessary to support its review of the NuScale design certification. Provide a justification for the deletion of COL Item 3.5-2 explaining why a COL applicant would not need to demonstrate protection from the effects of missiles from a co-located facility or add COL Item 3.5-2 back into the NuScale design certification.
NuScale Nonproprietary
NuScale Response:
COL Item 3.5-2 has been added back into the NuScale design certification.
Impact on DCA:
The FSAR has been revised as described in the response above and as shown in the markup provided in this response.
NuScale Nonproprietary
NuScale Final Safety Analysis Report Interfaces with Certified Design RAI 01-61, RAI 02.04.13-1, RAI 03.04.01-4, RAI 03.04.02-1, RAI 03.04.02-2, RAI 03.04.02-3, RAI 03.05.01.03-1, RAI 03.05.01.04-1, RAI 03.05.02-2, RAI 03.05.03-4, RAI 03.06.02-6, RAI 03.06.02-15, RAI 03.06.03-11, RAI 03.07.01-2, RAI 03.07.01-3, RAI 03.07.02-6S1, RAI 03.07.02-6S2, RAI 03.07.02-8, RAI 03.07.02-12, RAI 03.07.02-15S5, RAI 03.08.04-3S2, RAI 03.08.04-23S1, RAI 03.08.04-23S2, RAI 03.08.05-14S1, RAI 03.09.02-15, RAI 03.09.02-48, RAI 03.09.02-67, RAI 03.09.02-69, RAI 03.09.03-12, RAI 03.09.06-5, RAI 03.09.06-6, RAI 03.09.06-16, RAI 03.09.06-16S1, RAI 03.09.06-27, RAI 03.11-8, RAI 03.11-14, RAI 03.11-14S1, RAI 03.11-18, RAI 03.13-3, RAI 04.02-1S2, RAI 05.02.03-19, RAI 05.02.05-8, RAI 05.04.02.01-13, RAI 05.04.02.01-14, RAI 05.04.02.01-19, RAI 06.02.06-22, RAI 06.02.06-23, RAI 06.04-1, RAI 09.01.01-20, RAI 09.01.02-4, RAI 09.01.05-3, RAI 09.01.05-6, RAI 09.03.02-3, RAI 09.03.02-4, RAI 09.03.02-5, RAI 09.03.02-6, RAI 09.03.02-8, RAI 10.02-1, RAI 10.02-2, RAI 10.02-3, RAI 10.02.03-1, RAI 10.02.03-2, RAI 10.03.06-1, RAI 10.03.06-5, RAI 10.04.06-1, RAI 10.04.06-2, RAI 10.04.06-3, RAI 10.04.10-2, RAI 11.01-2, RAI 12.03-55S1, RAI 13.01.01-1, RAI 13.01.01-1S1, RAI 13.02.02-1, RAI 13.03-4, RAI 13.05.02.01-2, RAI 13.05.02.01-2S1, RAI 13.05.02.01-3, RAI 13.05.02.01-3S1, RAI 13.05.02.01-4, RAI 13.05.02.01-4S1, RAI 14.02-7, RAI 19-31, RAI 19-31S1, RAI 19-38, RAI 20.01-13 Table 1.8-2: Combined License Information Items Item No. Description of COL Information Item Section COL Item 1.1-1: A COL applicant that references the NuScale Power Plant design certification will identify the 1.1 site-specific plant location.
COL Item 1.1-2: A COL applicant that references the NuScale Power Plant design certification will provide the 1.1 schedules for completion of construction and commercial operation of each power module.
COL Item 1.4-1: A COL applicant that references the NuScale Power Plant design certification will identify the 1.4 prime agents or contractors for the construction and operation of the nuclear power plant.
COL Item 1.7-1: A COL applicant that references the NuScale Power Plant design certification will provide site- 1.7 specific diagrams and legends, as applicable.
COL Item 1.7-2: A COL applicant that references the NuScale Power Plant design certification will list additional 1.7 site-specific piping and instrumentation diagrams and legends as applicable.
COL Item 1.8-1: A COL applicant that references the NuScale Power Plant design certification will provide a list of 1.8 departures from the certified design.
COL Item 1.9-1: A COL applicant that references the NuScale Power Plant design certification will review and 1.9 address the conformance with regulatory criteria in effect six months before the docket date of the COL application for the site-specific portions and operational aspects of the facility design.
COL Item 1.10-1: A COL applicant that references the NuScale Power Plant design certification will evaluate the 1.10 potential hazards resulting from construction activities of the new NuScale facility to the safety-related and risk significant structures, systems, and components of existing operating unit(s) and newly constructed operating unit(s) at the co-located site per 10 CFR 52.79(a)(31).
The evaluation will include identification of management and administrative controls necessary to eliminate or mitigate the consequences of potential hazards and demonstration that the limiting conditions for operation of an operating unit would not be exceeded. This COL item is not applicable for construction activities (build-out of the facility) at an individual NuScale Power Plant with operating NuScale Power Modules.
COL Item 2.0-1: A COL applicant that references the NuScale Power Plant design certification will demonstrate 2.0 that site-specific characteristics are bounded by the design parameters specified in Table 2.0-1.
If site-specific values are not bounded by the values in Table 2.0-1, the COL applicant will demonstrate the acceptability of the site-specific values in the appropriate sections of its combined license application.
COL Item 2.1-1: A COL applicant that references the NuScale Power Plant design certification will describe the 2.1 site geographic and demographic characteristics.
COL Item 2.2-1: A COL applicant that references the NuScale Power Plant design certification will describe 2.2 nearby industrial, transportation, and military facilities. The COL applicant will demonstrate that the design is acceptable for each potential accident, or provide site-specific design alternatives.
COL Item 2.3-1: A COL applicant that references the NuScale Power Plant design certification will describe the 2.3 site-specific meteorological characteristics for Section 2.3.1 through Section 2.3.5, as applicable.
COL Item 2.4-1: A COL applicant that references the NuScale Power Plant design certification will investigate 2.4 and describe the site-specific hydrologic characteristics for Section 2.4.1 through Section 2.4.14, except Section 2.4.8 and Section 2.4.10.
COL Item 2.5-1: A COL applicant that references the NuScale Power Plant design certification will describe the 2.5 site-specific geology, seismology, and geotechnical characteristics for Section 2.5.1 through Section 2.5.5, below.
Tier 2 1.8-3 Draft Revision 3
NuScale Final Safety Analysis Report Interfaces with Certified Design Table 1.8-2: Combined License Information Items (Continued)
Item No. Description of COL Information Item Section COL Item 3.2-1: A COL applicant that references the NuScale Power Plant design certification will update Table 3.2 3.2-1 to identify the classification of site-specific structures, systems, and components.
COL Item 3.3-1: A COL applicant that references the NuScale Power Plant design will confirm that nearby 3.3 structures exposed to severe and extreme (tornado and hurricane) wind loads will not collapse and adversely affect the Reactor Building or Seismic Category I portion of the Control Building.
COL Item 3.4-1: A COL applicant that references the NuScale Power plant design certification will confirm the 3.4 final location of structures, systems, and components subject to flood protection and final routing of piping.
COL Item 3.4-2: A COL applicant that references the NuScale Power plant design certification will develop the 3.4 on-site program addressing the key points of flood mitigation. The key points to this program include the procedures for mitigating internal flooding events; the equipment list of structures, systems, and components subject to flood protection in each plant area; and providing assurance that the program reliably mitigates flooding to the identified structures, systems, and components.
COL Item 3.4-3: A COL applicant that references the NuScale Power plant design certification will develop an 3.4 inspection and maintenance program to ensure that each water-tight door, penetration seal, or other degradable measure remains capable of performing its intended function.
COL Item 3.4-4: A COL applicant that references the NuScale Power plant design certification will confirm that 3.4 site-specific tanks or water sources are placed in locations where they cannot cause flooding in the Reactor Building or Control Building.
COL Item 3.4-5: A COL applicant that references the NuScale Power Plant design certification will determine the 3.4 extent of waterproofing and dampproofing needed for the underground portion of the Reactor Building and Control Building based on site-specific conditions. Additionally, a COL applicant will provide the specified design life for waterstops, waterproofing, damp proofing, and watertight seals. If the design life is less than the operating life of the plant, the COL applicant will describe how continued protection will be ensured.
COL Item 3.4-6: A COL applicant that references the NuScale Power Plant design certification will confirm that 3.4 nearby structures exposed to external flooding will not collapse and adversely affect the Reactor Building or Seismic Category I portion of the Control Building.
COL Item 3.4-7: A COL applicant that references the NuScale Power Plant design certification will determine the 3.4 extent of waterproofing and damp proofing needed to prevent groundwater and foreign material intrusion into the expansion gap between the end of the tunnel between the Reactor Building and the Control Building, and the corresponding Reactor Building connecting walls.
COL Item 3.5-1: A COL applicant that references the NuScale Power Plant certified design will provide a missile 3.5 analysis for the site-specific turbine generator which demonstrates that protection from turbine missiles is accomplished by using barriers.
COL Item 3.5-2: A COL applicant that references the NuScale Power Plant certified design will address the effect 3.5 of turbine missiles from nearby or co-located facilities.Not Used.
COL Item 3.5-3: A COL applicant that references the NuScale Power Plant certified design will confirm that 3.5 automobile missiles cannot be generated within a 0.5-mile radius of safety-related structures, systems, and components and risk-significant structures, systems, and components requiring missile protection that would lead to impact higher than 30 feet above plant grade.
Additionally, if automobile missiles impact at higher than 30 feet above plant grade, the COL applicant will evaluate and show that the missiles will not compromise safety-related and risk-significant structures, systems, and components.
COL Item 3.5-4: A COL applicant that references the NuScale Power Plant design certification will evaluate site- 3.5 specific hazards for external events that may produce more energetic missiles than the design basis missiles defined in FSAR Tier 2, Section 3.5.1.4.
COL Item 3.6-1: A COL applicant that references the NuScale Power Plant design certification will complete the 3.6 routing of piping systems outside of the CNV and the area under the bioshield, identify the location of high- and moderate-energy lines, and update Table 3.6-1 as necessary.
Tier 2 1.8-4 Draft Revision 3
NuScale Final Safety Analysis Report Missile Protection are ASME Class 1 or 2 and therefore not credible missile sources as discussed in Section 3.5.1.1.1.
A control rod drive mechanism (CRDM) housing failure, sufficient to create a missile from a piece of the housing or to allow a control rod to be ejected rapidly from the core, is non-credible. The CRDM housing is a Class 1 appurtenance per ASME Section III.
3.5.1.3 Turbine Missiles RAI 10.02-3, RAI 10.02.03-1, RAI 10.02.03-2 The turbine generator building layout in relation to the overall site layout is shown on Figure 1.2-2. The turbine generator rotor shafts are physically oriented such that the RXB, CRB, and RWB are within the turbine trajectory hazard zone and considered to be unfavorably oriented with respect to the NPMs, as defined by RG 1.115, Revision 2.
Appendix A of RG 1.115, Rev. 2 identifies SSC requiring protection from turbine missiles. The SSC that require protection from turbine missiles (high-trajectory and low-trajectory turbine rotor and blade fragments) are located in either the RXB, the CRB, the RWB, or underground.
RAI 10.02-3, RAI 10.02.03-1, RAI 10.02.03-2 Protection from turbine missiles is accomplished by using barriers instead of the statistical significance criteria outlined in Section 3.5.1. The Seismic Category I RXB and CRB provide protection from turbine missiles for SSC located within each building. The SSC located underground are protected by their depth below grade. The SSC located in the Seismic Category II RWB are not protected from the effects turbine missiles.
However, any radioactive release that might result from the effects of a turbine missile is bounded by the failure of the gaseous radioactive waste system postulated in Section 11.3.3 and the resultant doses presented in Table 11.3-9.
RAI 03.05.03-4, RAI 10.02-3, RAI 10.02.03-1, RAI 10.02.03-2 COL Item 3.5-1: A COL applicant that references the NuScale Power Plant certified design will provide a missile analysis for the site-specific turbine generator which demonstrates that protection from turbine missiles is accomplished by using barriers.
RAI 03.05.01.03-1, RAI 10.02-3, RAI 10.02.03-1, RAI 10.02.03-2 COL Item 3.5-2: A COL applicant that references the NuScale Power Plant certified design will address the effect of turbine missiles from nearby or co-located facilities.Not used.
3.5.1.4 Missiles Generated by Tornadoes and Extreme Winds Hurricane and tornado generated missiles are evaluated in the design of safety-related structures and risk-significant SSC outside those structures. The missiles used in the evaluation are assumed to be capable of striking in all directions and conform to the Region I missile spectrums presented in Table 2 of RG 1.76, Rev. 1, "Design-Basis Tornado and Tornado Missiles for Nuclear Power Plants" for tornado missiles and Table 1 and Table 2 of RG 1.221, Rev. 0, "Design-Basis Hurricane and Hurricane Missiles for Nuclear Power Plants," for hurricane missiles. These spectra are based on the design Tier 2 3.5-5 Draft Revision 3