8/20/1976, Technical Specifications Changes (Appendices a and B). Amendment to Facility Operating License
ML18283B751
Person / Time
Site: Browns Ferry  Tennessee Valley Authority icon.png
Issue date: 08/20/1976
From: Schwencer A
Office of Nuclear Reactor Regulation
To: Goller K, Gerald Williams
Tennessee Valley Authority
References
Download: ML18283B751 (14)


Text

AUG 2 p tg7g DocketsINos.

and 50-260 Tennessee Valley Authority-ATTN:

Nr. Godwin Williams, Jr.

Manager of Power 818 Power Building Chattanooga, Tennessee 37201 Gentlemen:

Following the August 20, 1976 Licensing Board Initial Decision authorizing the issuance of the fire related portions of the enclosed Amendments (item a below), the Coamission has issued these Amendments, Nos. P-9 and &-'fto Facility Licenses Nos.;DPR-33 and DPR-52 for Browns Ferry Nuclear Plant, Units Nos.

1 and 2.

f These amendments add license conditions relating to the completion of facility modifications for fire protection and include changes to the Technical Specifications that:

(a)

Reinstate the Technical Specifications for operation suspended pending completion of restoration work and modifications required as a result of the thrch 22, 1975 fire.

This work and these modifications have been reviewed and accepted by NRC and have been completed by TVA; r

(b)

Incorporate operating limits based on an acceptable evaluation model that conforms UIith the requirements of Section 50.46 of 10 CFR Part 50, and terminates restrictions imposed on the facility by the Cormission's December 27, 1974 Order for t1odification of License; I

(c)

Permit the use of operating limits based on the General Electric Thermal Analysis Basis (GETAB);

(d)

Revise temperature limits for the suppression pool water; (e)

Revise Charcoal Filter Testing Requirements;

. (f)

Add Hydraulic Snubber Testing and Inspection requir~e t,

(g)

Add limiting conditions for operation associated with cracked collet housings of control rod drive mechanisms; 0M~o 02.Q OPPICR3h SVRNAMR~

OATR3P 4 V 41 OOVCRNMENT PRINTINO OPPICKI 1074 III140 POIIa hEC 318 (Rer. 9-33) hECM 0240

VB O~ ~~"

Il I ~

1' I

r I'

II

a (f

Tennessee Val 1ey Authority 2

AUG 2 p tg76 (h)

Change control rod reactivity limitations; (i)

Permits substitution of, a thermosetting plastic coating and sur-veillance for torus corrosion protection in lieu of chromate in the torus water; (3)

Change the'method for personnel protection for High Radiation Areas; (k)

Eliminate absolute calibration of Intermediate Range Monitors of neutron monitoring system; and (1)

Incorporate the radiological environmental monitoring program, formerly in Appendix A, into Appendix B.

Oopies of the Safety Evaluation, and the Federal Register Notice are also enclosed.

Sincerely,

Enclosures:

l.

Amendment No. 07 to DPR-33 2.

Amendment Ho. pg to DPR-52 3.

Safety Evaluation 4.

Federal Register Notice A. Schwencer, Chief Operating Reactors Branch 81 Division of Operating Reactors cc w/encl:

See next page SEE PREVIOUS YELLOW FOR CONCURRENCES AND DISTRIBUTION DOR:ORBIcI1 OPPI Cd ~

TVMambac.h...........

.............S/20/..76.

0URNAMd&

OATd~

1tOIdl hEC-318 (RCT. 9-$ 3) hECM 0240

... OR:.ORB...,...

.,KRGol,l.er..

...8/....../.76,....

k U, d."OOVdRNMdNT PRINTINO OPPICdI 1074 020 100

.DOR.:.ORBS'l..

ASchwencer.

8/.,/7.6....

gag gR BOA I

r II I4 f

, Tennessee Valley Authority 2

>)

Change control rod reactivity limitations; (i)

Permits substitution of a thermo-setting pla ic coating and sur-illance for torus corrosion protection i ieu of chromate in th torus Mater; (j)

Change he vpthod for personnel proto ion for',High Radiation Areas; and (k)

Eliminate abs Jute calibration of nterrddfate Range Yanitors of neutron monitortag-system, On August 20,~1976 the Li ensing B

rd issued its Initial Decision authorizing the issuance o

theW re related portions of the Amendments (itema).

Copies of the Safety Evaluati n and the Federal Register Notice and Initial Dec)sion are also e

los

ncerely, A. Schwe car, Chief Operating Reactors Branch 81 Division of Operating Reactors

Enclosures:

Amen nt No. 27 to DPR-33 2.

Amen ent No. 24 to DPR-52 3.

Saf y Evaluation 4.

Fe eral Register Notice 5.

I itial Decision cc i/enclosures:

Se next page

- SEE PREVIOUS YELLOW FOR CONCURRENCES DISTRIBUTION Docket (2)

NRC PDR (2)

Local PDR ORB81 Reading KRGoller/TJCarter SHSheppard TVWambach RBaer DEisenhut OELD OISIN(5)

Bygones(8)

BScharf(15)

JttcGough ACRS(16)

DRoss VStello TBAbe JRBuchanan JSal tzman AESteen OFFICS3F'27433 SUANAMAW ORBgl Tl/1/ambach: tb 8/20/76 Form hZC-318 (Rcv. 9.33) hXCM 0240 Q Tl

.....DOR:.OT......,.....

.......BEisenbut.

..8l......../7.6...

RSB

..IID~g...,...,

RB21,...,...,...,

...KRho ler.--.--. -ASchwencer-

...8/4.0../.7.6...,..... 8/...- /76 - -.

-OELD---------

,RBaer...,....,......,,...,

8/

/76 8/.........../7.6.........

4 II, SI 4OVAANMSNTFAINTIN4OFFICAI 1074 024 ISS

I t

c k

I

Tennessee Valley Authority

. August 20, 1976 cc:

H.

S.

Sanger General Counsel 629 New Sprankle Building Knoxvile, Tennessee 37919 Mr. William E. Garner Route 4, Box 354 Scottsboro, Alabama 35768 Athens Public Library South and Forrest

Athens, Alabama 3561.

Mr. Thomas Lee Hammons

Chairman, Limestone County Board of Revenue
Athens, Alabama 35611 Ira L. Myer s, M,D.

State Health Officer State Department of Public Health State Office Building Montgomery, Alabama 36104

~pl 4E00s

~

(Q a

P Cy+

. p1~

UNITEDSTATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 TENNESSEE VALLEY AUTHORITY DOCKET NO. 50-259 BROWNS FERRY NUCLEAR PLANT UNIT 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No." 27 License No.

DPR-33 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The applications for amendments by Tennessee Valley Authority (the licensee) comply with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the CommissionIs rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the applications, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can'be conducted without endangering the.'ealth and safety of the public, and (ii) that such activities will be conducted in compliance with the Commissiori's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

4 2.

Accordingly, Facility Operating License No.

DPR-33 is amended as indicated below and the Technical Specifications are reinstated as indicated in the attachment to this license amendment.

A Change paragraph

<<D<< to iiE B.

Add new paragraph D to read as follows:

"D, This license is subject to the following additional conditions

~

(1)

The licensee is required to complete the following five plant modifications in the facility, which are related to the Fire Recovery Program, by the end of the first refueling outage of any of Browns Ferry Nuclear Plant, Units 1, 2, or 3, (a)

Install automatic deluge systems for all areas of cable trays where Division 1 and Division 2 cabling could be involved in the same fire; i

(b)

Install automatic pre-action sprinkler systems in all areas of the plant required for safe shutdown; (c)

Install a manual dry pipe sprinkler system in the cable spreading rooms; (d)

Change installed manual carbon dioxide system in the cable spreading rooms to automatic actuation; and (e)

Change the fire protection features of the battery room complex to do one of the following:

(1) pro-vide a total fire rated barrier enclosure of the facility battery room complex that exceeds the fire load contained in the room, (2) reduce the fire load to be within the fire barrier capability of l-l/2 hours, or (3) provide a remote manual

, actuated 'sprinkler system in each room and provide the l-l/2 hours fire barrier separation.

(2)

The'icensee is required to assure that all fire brigade members will have received within.18 months an accel-erated refresher training program conforming to the requirements of Section 2, 2 of Supplement No, 2 tothe Safety Evaluation Supporting the Operation After the Restoration and Modification of the Browns Ferry Nuclear Plant, Units 1 and 2 Following the March 22, 1975 Fire, Issued July 3, 1976 '

C.

Revise paragraph 2.C. (4) to read as follows:

IT(4)

The facility may be modified as described in Section X of 'Plan for Evaluation,

Repair, and Return to Service of Browns Ferry Units 1 and 2 (March 22, 1975 Fire)'ated April 13, 1975, and revisions thereto."

D.

Add paragraph 2.C. (7) to read as follows:

"(7)

The facility may be modified as described in 'Browns Ferry Nuclear Plant Units 1 and 2 Emergency Core Cooling Systems Low Pressure Coolant Injection Modifications for Performance Improvement (December 1975) 'ubmitted by application dated December 1, 1975 and supplements dated February 12,

1976, March 24, 1976, March 30, 1976, May 21,
1976, June ll, 1976, and July 21, 1976.~

3.

This license amendment is effective as of the date of issuance.

FOR THE NUCLEAR REGULATORY COt&ESSION Karl R. Goller, Assistant Director for Operating Reactors Division of Operating-Reactors

Attachment:

Technical Specifications (Appendices A and B)

Date of Issuance:,

August 20,, 1976

~gS ItfCy Ci+

0p

~

0

+, ~.

+**+~

f UNITEDSTATES NUCLEAR REGULATORY COMMISSION WASHINDTON, D. C. 20555 TENNESSEE VALLEY AUZHORITY DOCKET NO. 50-260 BRORNA S FERRY NUCLEAR PLANT UNIT 2 AIIENDNENT TO I'ACILITT OPERATING LICENSE Amendment No. 24 License No. DPR-55 1.

The'Nuclear Regulatory Commission (the Commission) has found that:

A.

The applications for amendments by Tennessee Valley Authority (the licensee) comply with the standards and requirements of the At6mic Energy Act of 1954, as amended (the Act), and the CommissionIs rules and regulations set forth in 10 CFR Chapter I; 8,

The facility will operate in conformity with the applications, the provi'sions of the Act, and the rules and regulations of the Commission; C.

There is reasonable, assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in 'accordance with 10 CFR Part 51:

of the Commission's regulations and all applicable requirements have been satisfied, 2.

A'ccordingly, Facility Operating License No.

DPR-55 is amended as indicated below and the Technical Specifications are reinstated as indicated in the attachment to this license amendment.

A.

Change paragraph "D" to "E",

B.

Add new paragraph D to read as follows:

"D.

This license is subject to the following additional conditions

~

(1)

The licensee is required to complete the following five plant modifications in the facility, which are related to the Fire Recovery

Program, by the end of the first refueling outage of any of Browns Ferry Nuclear Plant, Units 1, 2, or 3.

(a)

Install automatic deluge systems for all areas of cable trays where Division 1 and Division 2 cabling could be involved in the same fire; (b)

Install automatic pre-action sprinkler systems in all areas of the plant required for safe shutdown; (c)

Install a manual dry pipe sprinkler system in the cable spreading rooms; (d)

Change installed manual carbon dioxide system in the cable spreading rooms to automatic actuation; and (e)

Change the fire protection features of the battery room complex to do one of the following:

(1) pro-vide a total fire rated barrier enclosure of the facility battery room complex that exceeds the fire load contained in the room, (2) reduce the fire load to be within the fire barrier capability of l-l/2 hours, or (3) provide a remote manual actuated sprinkler system in each room and provide the l-l/2 hours fire barrier separation.

(2)

The, licensee is required to assure that all fire brigade members will have received within 18 months an accel-erated refresher training program conforming to the requirements of Section

2. 2 of Supplement No, 2 to the Safety Evaluation Supporting the Operation After the Restoration and Modification of the Browns Ferry Nuclear Plant, Units 1 and 2 Following the March 22, 1975 Fire, Issued July 3, 1976,"

C.

Revise paragraph 2.C.(5) to read as follows:

"(5)

The facility may be modified as described in Section X of 'Plan for Evaluation,

Repair, and Return to Service of Browns Ferry Units 1 and 2 (March 22, 1975 Pire)'ated April 13, 1975, and revisions thereto."

D.

Add paragraph

2. C.(7) to read as follows:

"(7)

The facility may be modified as described in 'Browns Ferry Nuclear Plant Units 1 and 2 Emergency Core Cooling Systems Low Pressure Coolant Infection Modifications for Performance Improvement (December 1975)'ubmitted by application dated December 1, 1975 and supplements dated February 12, 1976, March 24, 1976, March 30, 1976, May 21, 1976'une lip 1976'nd July 21'976 This license amendment is effective as of the date of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION Karl R. Goller, Assistant Director for Operating Reactors Division of Operating Reactors

Attachment:

Technical Specifications (Appendices A and-B)

Date of Issuance:

AuguSt, 20, 1976

ATTACHMENT TO LICENSE AMENDMENTS AMENDMENT NO.

27 TO FACILITY LICENSE NO. DPR-33 AMENDMENT NO.

24 TO FACILITY LICENSE NO.

DPR-52 DOCKETS NOS. 50-259 AND 50-260 Appendices A and B are revised in their entirety by the attached Appendices A and B.