Docket No.

50-296

&g-gpss

'stribution

~Wocket UNITED STATES NUCLEAR REGULATORY COMMISSION.,

WASHINGTON, D.C. 20555 December 4, 1979 Docketing and Service Section Office of the Secretary of the Commission Brotlns Ferr Unit 3 T A Two signed originals ofthe Federal Register Notice identified below are enclosed foryour transmittal to the Office ofthe Federal Register forpublication. Additional conformed copies ( )2 ) of the Notice are enclosed for your use.

0 Notice of Receipt of Application for Construction Permit(s) and Operating License(s).

0 Notice of Receipt of Partial Application forConstruction Permit(s) and Facility License(s): Time for Submission of Views on Antitrust Matters.

CI Notice of Availabilityof Applicant's Environmental Report.

Kl Notice of RK@pdSUU Issuance of Amendment to Facility Operating License.

CI Notice. of Receipt of Application for Facility License(s);

Notice of Availability of Applicant's Environmental Report; and Notice of Consideration of Issuance of Facility License(s) and Notice of Opportunity for Hearing.

0 Notice of Availabilityof NRC Draft/Final Environmental Statement.

0 Notice of Limited Work Authorization.

0 Notice of Availabilityof Safety Evaluation Report.

0 Notice of Issuance of Construction Permit(s).

Cl Notice of Issuance of Facility Operating License(s) or Amendment(s).

g Other; Referenced documents a

b e d d

Enclosure:

As Stated Office of Nuclear Reactor Regulation ORB 83 OFFICE~

SURNAME~

OATE~

NAC FORM 102 (1.76)

ORB A'3 SShapparpp 12/ /I/79

t i E 1

sk h

8

UNITED STATES NUCLEAR REGULATORY COMMISSION DOCKET NO. 5Q-296 TENNESSEE VALLEY AUTHORITY NOTICE OF ISSUANCE OF AMENDMENT TO FACILITY OPERATING LICENSE The U. S. Nuclear Rhgulatory Conmission (the Commission) has issued Amendment No.

28 to Facility Operating License No.

DPR-68 issued to the Tennessee Valley Authority (the l.icensee),

which revised'echnical Specifications for operation of the Browns Ferry Nuclear Plant, Unit No. 3, located in Limestone County, Alabama.

The amendment is effective as of the date of issuance.

This amendment changes the Technical Specifications to:

(1) incorporate the limiting conditions for operation during the third fuel cycle, (2) reflect facility modifications made during the current refueling outage.to eliminate the low pressure coolant injection loop selection logic (an action which the Commission required to be accomplished and the design for which the Commission approved in Amendment No.

23 to Operating License No.

DPR-68 dated May ll, 1979),

(3) reflect rerouting of the reactor water cleanup system piping to reduce thermal cycling on the feedwater nozzles (and thus provide increased margin against the initiation and propagation of cracks in these nozzles),

and (4) reflect replacement of two of the ll safety-relief valves with valves of an improved design that will provide a slightly increased simmer margin (i.e., the two replacement valves will be set to relieve at 1150 psig rather than 1125 psig).

I The application for the amendment complies with the standards and requirements of the Atomic Energy Act of 1954,"as amended (the Act), and

75+)1 the Commission's rules and regulations.

The Commission has made appropriate findings as required by the Act and the Commission's rules and regulations in 10 CFR Chapter I, which are set forth in the license amendment.

Prior public notice of this amendment was not required since the amendment does not involve a significant hazards consideration.

The Commission has determined that the issuance of this amendment will not result in any significant environmental impact and that pursuant to 10 CFR

'Section 51.5(d)(4) an environmental impact statement or negative declaration and environmental impact appraisal need not be prepared in connection with the issuance of this amendment.

For further details with respect to this action, see (1) the application for amendment dated August 6,

1979, as supplemented by two letters dated 4.

September 26, 1979 and letters dated October 10, 1979 and October ~5,

1979, (2) Amendment No. 28 to License No.

DPR-68, and (3) the Commission's related Safety Evaluation.

All of these items are available for public inspection at the Commission's Public Document

Room, 1717 H Street, N; W., Washington, D.

C.

and at the Athens Public Library, South and Forrest,

Athens, Alabama 35611.

A copy of items (2) and (3) may be obtained upon request addressed to the U. S.

Nuclear Regulatory Comisssion, Washington, D.

C.

20555, Attention:

Director, Division of Operating Reactors.

.FOR THE NUCLEAR REGULATORY COMMISSION II I

Thomas A.

oli o, Chief Operating Reactor s Branch 83 Division of Operating Reactors Dated at Bethesda, Maryland this 30th day of November 1979,

'E