Attn: Document Control Desk Department of Energy Idaho Operations Office 1955 Fremont A venue Idaho Falls, ID 83415 September 26, 2018 Director, Division of Spent Fuel Storage and Transportation Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

SUBJECT:

Submittal of Reponses to NRC Requests for Additional Information for the Technical Review of the Three Mile Island Unit 2 Independent Spent Fuel Storage Installation License Renewal Application, Docket 72-0020 (EM-NRC-18-023)

REFERENCES:

1) DOE-ID Letter EM-NRC-17-007 to NRC: "Submittal of Application for Renewal ofTMI-2 ISFSI License SNM-2508," dated March 6, 2017
2) NRC Letter: Mr. John P. Zimmerman, Deputy Manager, Idaho Cleanup Project, "Request for Additional Information for the Technical Review of the Application for Renewal of the Three Mile Island Unit 2 Independent Spent Fuel Storage Installation License No. SNM-2508 (CAC/EPID NOS.

001028/L-2017-RNW-0019 AND 000993/L-2017-LNE-0007)," dated January 29, 2018

Dear Sir or Madam:

On March 6, 2017, the Department of Energy, Idaho Operations Office (DOE-ID) submitted a license renewal application (LRA) requesting a 20-year renewal of Three Mile Island Unit 2 (TMl-2) Independent Spent Fuel Storage Installation (ISFSI) specific license SNM-2508 (Reference 1) (ADAMS Accession Nos. MLl 7089A501 and MLl 7075Al 99 through MLl 7075A201). The Nuclear Regulatory Commission (NRC) acknowledged acceptance of the LRA on May 5, 2017 (ADAMS Accession No. MLl 7125A284).

On January 29, 2018 DOE-ID received from the NRC a Request for Additional Information (RAI) (ADAMS Accession No. ML18030Al 72) pertaining to the technical review associated with the TMI-2 ISFSI LRA (Reference 2). Enclosure 1 to this letter contains the NRC RAis and provides the DOE-ID responses. Also enclosed (enclosure 2) with this submittal is Revision 1 of the LRA, which includes changes that reflect the responses to the RAis. As requested by the NRC in our June 7, 2018 public meeting, design drawings and an approved update to certain TMl-2 ISFSI FSAR information are being provided under separate cover. This updated FSAR information will be included in the next biennial TMI-2 ISFSI FSAR update.

Document Control Desk EM-NRC-18-023 Should you have questions or require additional information, please contact me at (208) 526-5531, or Steve Wahnschaffe at (208) 526-4993.

Scott Ferrara Alternate License Manager

Enclosures:

1)

Responses to NRC Request for Additional Information on the TMI-2 ISFSI License Renewal Application

2)

TMI-2 ISFSI License Renewal Application, Revision 1 cc: Kristina Banovac, NRC (w/ electronic enclosure)

Bernard White, NRC (w/ electronic enclosure)

Meraj Rahimi, NRC (w/ electronic enclosure)

Nicholas DiNunzio, DOE HQ (w/ electronic enclosure)

Greg Sosson, DOE HQ (w/ electronic enclosure)