Clinton Power Station After Action Report/

Improvement Plan Drill Date - June 28, 2018 Radiological Emergency Preparedness Program Published Septeniber 3, 2018

Unclassified Radiological Emergency Preparedness Program After Action Report/Improvement Plan Clinton Power Station This page is intentionally blank.

  • unclassified

. Radiological Emergency Preparedness Program After Action Report/Improvement Plan Clinton Power Station Clinton Power Station*

After Action Report/Improvement Plan Published September 3, 2018 Contents Executive Summary Section 1: Exercise Overview 1.1 Exercise Details 1.2 Exercise Planning Team Leadership 1.3 Participating Organizations Section 2: Exercise Design Summary 2.1 Exercise Purpose and Design 2.2 Exercise Objectives, Capabilities and Activities 2.3 Scenario Summary Section 3: Analysis of Capabilities 3.1 Drm Evaluation and Results 3.2 Summary Results of Drill Evaluation 3.3 Criteria Evaluation Summaries 3.3. 1 Illinois Jurisdictions 3.3.1.1 State of Illinois - OSF - St. Joseph Medical Center -

Medical Service - Transportation 3.3.1.2 State of Illinois - OSF - St. Joseph Medical Center -

Medical Service - Facility Section 4: Conclusion Appendix A: Drill Evaluators and Team Leaders Appendix B: Exercise Plan 1

3 8

8 8

10 11 11 11 12 13 13 14 16 16 16 16 17 18 19

Unclassified Radiological Emergency Preparedness Program After Action Report/Improvement Plan Clinton Power Station This page is intentionally blank.

2

Unclassified Radiological Emergency Preparedness Program After Action Report/Improvement Plan Clinton Power Station EXECUTIVE

SUMMARY

On June 28, 2918, the U.S. Department of Homeland Secutity's (DRS) Federal Emergency Management Agency (FEMA), Region V, evaluated a Medical Services (MS-1) Drill at the Order of Saint Francis (OSF) St. Joseph Medical Center associated with the Clinton Power Station. The purpose of the MS-1 Drill was to assess the ability of off site agencies to respond to

  • a medical emergency involving a potentially radiologically contaminated member of the public.

The MS-1 Drill was held in accordance with DHS/FEMA policies and guidance concerning the exercise of State and local radiological emergency response plans (RERPs) and procedures.

The DHS/FEMA wishes to acknowledge the efforts of the personnel from the Illinois Emergency Management Agency, Bloomington Fire Department, and the OSF St. Joseph Medical Center who paiticipated in the MS-1 Drill. Protecting the public health and safety is the full-time job of some of the exercise participants and an additio:nal assigned responsibility for others. Still others have willingly sought this responsibility by volunteering to provide vital emergency services to their communities.

The State and local organizations demonstrated knowledge of and adequately implemented organizational emergency response plans and procedures.

There were no Level 1 Findings, Level 2 Findings or Plan Issues identified as a result of this drill and there were no previous Level 1 Findings, Level 2 Findings or.Plan Issues to be corrected during this drill.

INTRODUCTION - EXERCISE BASIS On December 7, 1979, the President directed FEMA to assume the lead responsibility for all offsite nuclear planning and response. The DHS/FEMA's activities are conducted pursuant to Title 44 of the Code of Federal Regulations ( CPR) Parts 350 Review and Approval of State and Local Radiological Emergency Plans and Preparedness", 351 "Radiological Emergency Planning and Preparedness" and 352 "Commercial Nuclear Power Plants: Emergency Preparedness 3

Unclassified Radiological Emergency Preparedness Program After Action Report/Improvement Plan Clinton Power Station Planning" (Commonly referred to as 44 CFR 350 through 352). These regulations are a key element in the Radiological Emergency Preparedness (REP) Program that was established following the Three Mile Island Nuclear Station accident in March 1979.

FEMA Regulation 44 CPR 350 establishes the policies and procedures for DHS/FEMA's initial and continued approval of State and local governments' radiological emergency planning and preparedness for commercial nuclear power plants. This approval is contingent, in part, on State and local governments' participation in jo1nt exercises with licensees.

The DHS/FEMA's responsibilities in radiological emergency planning for fixed nuclear facilities include the following:

Taking the lead in offsite emergency planning and in the review and evaluation of RERPs and procedures developed by State and local governments; Determining whether such plans and procedures can be implemented on the basis of observation and evaluation of exercises of the plans and procedures conducted by State and local governments; Responding to requests by the U.S. Nuclear Regulatory Commission (NRC) pursuant to the Memorandum of Understanding between the NRC and FEMA dated October 1, 2015, and; Coordinating the activities of Federal agencies with responsibilities in the radiological emergency planning process:

U.S. Department of Agriculture; U.S. Department of Commerce; U.S. Department of Energy; U.S. Department of Health and H1,1man Services; U.S. Depaitment of the Interior; U.S. Depaitment of Transportation; U.S. Environmental Protection Agency; U.S. Food and Drug Administration; and U.S. Nuclear Regulatory Commission.

Representatives of these agencies serve on the DHS/FEMA Region V Regional Assistance Committee (RAC), which is chaired by DHS/FEMA.

4

Unclassified Radiological Emergency Preparedness Program After Action Report/Improvement Plan Clinton Power Station Formal submission of.the RERPs for the CPS to FEMA Region V by the State of Illinois and involved local jurisdictions occurred on November 25, 1986. Formal approval of these RERPs was granted by.FEMA on August 5, 1987, under 44 CPR 350.

The purpose of this After Action Rep01t (AAR)/Improvement Plan (IP)_ is to present the exercise results and findings based on the performance of the Offsite Response Organizations (OROs) during a medical emergency involving a potentially radiologically contaminated member of the public.

The findings presented in this AAR/IP are based on the evaluations of the Federal evaluation team, with final determinations made by the DHS/FEMA Region V RAC Chair, and approved by the DHS/FEMA Headquarters.

The criteria utilized in the FEMA evaluation process are contained in:

  • NUREG-0654/FEMA-REP-l, Rev. 1, "Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants," November 1980;
  • FEMA Radiological Emergency Preparedness: Exercise Evaluation Methodology, as published in the FEMA Radiological Emergency Preparedness Program Manual, dated January 2016.

Section 1 of this report, entitled Exercise Overview," presents information pertaining to the team that planned and coordinated the exercise. This section also provides a listing of all participating jurisdictions and functional entities that were evaluated.

Section 2 of this rep01t, entitled "Exercise Design Summary," contains the purpose and design of the exercise, a description of the exercise objectives and presents basic information and data relevant to the exercise scenario.

Section 3 of this i*eport, entitled "Analysis of Capabilities," presents detailed information on the demonstration of applicable exercise criteria at each jurisdiction or functional entity evaluated in a jurisdiction-based, issues-only format. This section also contains: (1) descriptions of all 5

Unclassified Radiological Emergency Preparedness Program After Action Report/Improvement Plan Clinton Power Station Level 1 Findings, Level 2 Findings and Plan Issues if any, assessed during ~his exercise, recommended con-ective actions, and the State and local governments' schedule of corrective actions, if applicable, for each identified exercise issue; and (2) descriptions of unresolved Level 2 Findings assessed during previous exercises and the status of the OROs' efforts to resolve them.

Section 4 of this rep01t, entitled "Conclusion," presents the DHS/FEMA summary of overall exercise conduct and results as evaluated against the requirements of 44 CFR 350.

EMERGENCY PLANNING ZONE (EPZ) DESCRJPTION The CPS _is located approximately seven miles northeast of the City of Clinton in Harp Township, within DeWitt County, Illinois. DeWitt County is located near the geographical center of the State of Illinois. The topography of the area is predominantly rolling prairies.

The EPZ for the CPS is an area approximately the area of a ten-mile radius with the CPS as the center point. The EPZ extends approximately ten miles outward in all directions from the CPS for the plume exposure pathway planning zone and fifty miles outward for the ingestion exposure pathway planning zone. In the event of a serious accident at the CPS, the plume exposure EPZ will be the area in which intensive efforts will be made to notify and protect residents and transient population from exposure to radiation. The IO-mile EPZ contains a total population of 12,702 (2010 census) within the risk county of DeWitt, and the supp01t counties of Macon, McLean and Piatt. Nearly two-thirds of the total 10-mile EPZ population (8,422) resides in the communities of Clinton, Weldon, Wapella, and DeWitt. The land use within the 10-mile EPZ is predominantly agricultural, with cash grain crops of corn and soybeans. The closest industries are located in the community of Clinton.

Recreational facilities outside the municipalities include the Clinton Lake State Recreation Area and the Weldon Springs State Park. The park encompasses approximately 370 acres and contains a 28-acre lake with camping, fishing, and picnicking facilities. Weldon Springs is one of the two sizable lakes within 10 miles of the site. Clinton Lake is a 4,895 acre man-made cooling lake within the CPS property lines. Recreational facilities accommodate camping, boating, hunting, fishing and hiking.

The nearest major highways are State Highways 54, 10, and 48, all 9f which intersect the plant location. Other major thoroughfares are U.S. Highway 51, located about six miles west of the 6

Unclassified Radiological Emergency Preparedness Program Afier Action Report/Improvement Plan Clinton Power Station plant and Interstate Highway 74, located about 11 miles northeast of the plant. The nearest railroad is the Canadian National Railway (CN), which crosses the site east to west and comes within about three-fourths of a mile to the n01th of the reactor centerline. Another CN track is located approximately three and a half miles south of the CPS.

7

U nclassificd Radiological Emergency Preparedness Program After Action Report/Improvement Plan Clinton Power Station SECTION 1: EXERCISE OVERVIEW 1.1 Exercise Details Exercise Name Clinton Power Station Type of Exercise Medical Services Drill Exercise Date June 28,.2018 Program Department of Homeland Security/FEMA Radiological Emergency Preparedness Program Scenario Type Radiological Emergency 1.2 Exercise Planning Team Leadership Sean O'Leary Regional Assistance Committee, Chair

  • Chief, Technological Hazards Branch DHS/FEMA Region V 536 South Clark Street Chicago,IL,60605 (312) 408-5389 sean.oleary@fema.dhs.gov Stephen Tulley Exercise Director Supervisory REP Team Leader DHS/FEMA Region V 536 South Clark Street Chicago, IL, 60605 (312) 408-4425 stephen.tulley@fema.dhs.gov 8

Unclassified Radiological Emergency Preparedness Program After Action Report/Improvement Plan David Ortman Site Specialist Emergency Management Specialist DHS/FEMA Region V 536 South Clark Street Chicago, IL,.60605 (312) 408-4429 david.ortrnan@fema.dhs.gov Joni Estabrook State Controller IUinois Emergency Management Agency Clinton Power Station Nuclear Safety Sr. Emergency Response Coordinator 1035 Outer Park Drive Springfield, illinois, 62704 217-524-0888 joni.estabrook@illinokgov Ed Ingram Offsite Planner Exelon Offsite Programs 4300 Winfield Road Warrenville, Illinois, 60555 630-470-7859 edward.ingram@exeloncorp.com 9

Unclassified Radiological Emergency Preparedness Program After Action Rcpo1t/Improvemcnt Plan Clinton Power Station 1.3 Participating Organizations Agencies and organizations of the following jurisdictions participated in the Clinton Power Station drill:

State Jurisdictions Illinois Emergency Management Agency Order of Saint.Francis St. Joseph Medical Center Bloomington Fire Department 10

Unclassified Radiological Emergency Preparedness Program After Action Report/Improvement Plan Clinton Power Station SECTION 2: EXERCISE DESIGN

SUMMARY

2.1 Exercise Purpose and Design On June 28, 2018, the U.S. Department of Homeland Security's (DHS) Federal Emergency Management Agency (FEMA), Region V, evaluated a Medical Services (MS-1) Drill at the Order of Saint Francis St. Joseph Medical Center associated with the Clinton Power Station. The purpose of the MS-1 Ddll was to assess the ability of offsite agencies to respond to a medical emergency involving a potentially radiologically contaminated member of the public. The MS-1 Drill was held in accordance with the DHS/FEMA policies and guidance concerning the exercise of State and local radiological emergency response plans and procedures.

2.2 Exercise Objectives, Capabilities and Activities Exercise* objectives and identified Capabilities/REP Criteria selected to be demonstrated are discussed in Appendix B Exercise Plan."

The Exercise Planning Team (EPT) selected objectives that focus on evaluating emergency response procedures, identifying areas for improvement, and fostering collaboration between the various Offsite Response Organizations (OROs) and stakeholders.* The following criteria, which are part of the six Exercise Evaluation Areas described in the DHS/FEMA Radiological Emergency Preparedness (REP) Pro gram Manual, dated January 2016, were evaluated during the MS-1 Drill:

  • Criterion 1.e.1 - Equipment, maps, displays, dosimetry, potassium iodide (Kl), and other supplies are sufficient to support emergency operations.
  • Criterion 3.a. l - The Offsite Response Organizations (ORO) issue appropriate dosimetry, KI
  • and procedures, and manage radiological exposure to emergency workers in accordance with the plans and procedures. Emergency workers periodically and at the end of each mission read their dosimeters and record the readings on the appropriate record or chart. The ORO's maintain appropriate record-keeping of the administration of KI to emergency workers.

11

U ndassified Radiological Emergency Preparedness Program After Action Report/fmprovcment Plan Clinton Power Station

  • Criterion 6.d. l - The facility/ORO has the appropriate space, adequate resources, and trained personnel to provide transport, monitoring, decontamination, and medical services to contammated injured individuals.

2.3 Scenario Summary Appendix B Exercise Plan," contains a summary of the Exercise Scenario, a simulated sequence of events that was used as the basis for invoking emergency response actions by Offsite Response Organizations (OROs) in the Clinton Power Station MS-1 Drill.

During the exercise, controllers from the State of Illinois provided "inject messages" containing scenario events and/or relevant data to those persons or locations who would normally receive notification of such events. These inject messages were the method used for invoking additional specific response actions by OROs.

12

Unclassified Radiological Emergency Preparedness Program After Action Report/Improvement Plan Clinton Power Stalion SECTION 3: ANALYSIS OF CAPABILITIES 3.1 Drill Evaluation and Results Contained in this section are the results and findings of the evaluation of all jurisdictions and functional entities that participated in the June 28, 2018, Medical Services (MS-1) Drill conducted to assess the ability of offsite agencies to respond to a medical emergency involving a potentially.

radiologically contaminated member of the public.

Each jurisdiction and functional entity was evaluated based on its demonstration of exercise

  • criteria delineated in DHS/FEMA Radiological Emergency Preparedness: Exercise Evaluation Methodology; as published in the FEMA Radiological Emetgency Preparedness Program Manual, dated January 2016. Detailed information on the exercise criteria and the extent-of-play agreements used in this exercise are found in Appendix B "Exercise Plan" of this report.

Presented below are definitions of the terms used in this report relative to the criteria demonstration status:

M - Met: The status of a REP exercise Evaluation Area Criterion indicating that the participating Offsite Response Organization (ORO) demonstrated all demonstration criteria for the Evaluation Area Criterion to the level required in the extent-of-play agreement with no Deficiencies or Level 2 Finding assessed in the current exercise a~d no unresolved prior Level 2 Finding.

  • Ll - Level 1 Finding: An observed or identified inadequacy of organizational performance in an exercise that could cause a determination that off site emergency preparedness is not adequate to provide reasonable assurance that appropriate protective measures can be taken in the event of a radiological emergency to protect the health and safety of the public living in the vicinity of a nuclear power plant.
  • L2 - Level 2 Finding - An observed or identified inadequacy of organizational performance in an exercise that is not considered, by itself, to adversely-impact public health and safety.
  • P-Plan Issue -An observed or identified inadequacy in the ORO's emergency plan or implementing procedures, rather than in the ORO's performance.

13

U 11cla5sified Radiological Emergency Preparedness Program After Action Reporl/Improvement Plan Clinton Power Station 3.2 Summary Results of Drill Evaluation The matrix presented in Table 3.1, on the following pages, presents the status of all exercise criteria from the DHS/FEMA REP: Exercise Evaluation Methodology, as published in the DHS/FEMA REP Program Manual, dated January 2018, which were scheduled for demonstration during this exercise by all participating jurisdictions and functional entities. The criterion status box is blank if it was not scheduled for demonstration.

This subsection provides information on the evaluation of each participating jurisdiction and functional entity in a jurisdiction-based, issues-only format.

The DHS has developed a standardized system for numbering exercise issues. This system is used to achieve consistency in numbering exercise issues among DHS Regions and site-specific exercise rep01ts within each Region. It also is used to expedite tracking of exercise issues on a nationwide basis.

The identifying number of Level 1 Findings, Level 2 Finding, and Plan Issues includes the following elements, with each element separated by a hyphen(-).

  • Plant Site Identifier - A two-digit number, corresponding to the Utility Billable Plant Site Code (06 for Clinton Power Station).

Exercise Year - The last two digits of the year the exercise was conducted.

  • Criterion Number - An alpha and two-digit number corresponding to the criteria numbers in the six Exercise Evaluation Areas described in Part III.C of the DHS/FEMA REP Program Manual, January 2018.

Issue Classification Identifier- (Ll = Level 1 Finding, L2 = Level 2 Finding, P = Plan Issue).

  • Exercise Identification Number - A separate two or three-digit indexing number assigned to each issue identified in the exercise.

14

Unclassified Radiological Emergency Preparedness Program After Action Report/Improvement Plan Clinton Power Statiou Table 3.1 - Summary of Drill Evaluation DATE: 2018-06-28 SITE: Clinton Power Station, IL M: Met, L2: Level 2 Finding, L1: Level 1 Fjnding, P: Plan Issue, N: Not Demonstrated Mobilization Facilities lbl Direction and Control lcl Communications Eauipment ldl Equipment and Supplies to Support Operations.

lel M

M

  • p1ott?6t1rew<lttwi1D~i~l$.~~;M~~w:~iZ?:iJLrtJ?,;mrAt:;~t/¥~a4:&1~1;1:~tr£;vr~~&ltt2~:,~;1;t:.rff£ltii.t¥:t1\\tttii.J:: k~~ -

EW Exoosure Control Decisions 2al PARs 2bl PADs 2b2 PADs for Disabled/Functional Needs 2cl Ingestion PADs 2dl RRR Decisions EW Exoosure Control Irrmlementation 3al M

M KI Public/Institutionalized 3bl PAD Implementation Disabled/Functional Needs 3cl PAD Implementation Schools 3c2 TACP Establishment 3dl Impediments.

3d2 Implement Ingestion PADs 3el Ingestion Pathway Decisions 3e2 Imolementation of RRR Decisions 3fl F.ie1a:1v1AAsriF~~*~iifiafi<l1ki1JViti:~i1u#'it.~~~::;sks:.;s::}5~~f~~:i\\I.10-:a~~,.;%i~~~~;i;iii:;:~;=-1;;)fa>i:;kfo~E~iAif¥:*&:;;~,:::_:;mJ;hi~~J.w~Lifilll !

RESERVED 4al Field Team Management 4a2 Field Team Operations 4a3 Field Team Sampling 4b1 Laboratory Operations 4cl Eui\\1ie.n1iYd§.6hfi~_iit>Jfa[lft:Riibli.cii.~.f0.;~~~~.1£1~r.ii~.Ji~i2£,w!f~~gf~i~~Ai$ti~ii&~£~flt.:%~if..F~j,ft~~-t~~~~ii.~~¥~1~11#.~1~~~\\1kti4;.1-4~,~~1.~~i

!Jifiif Initial Alert & Notification 5al RESERVED 5a2 Backuu Alert & Notification 5a3 Exceolion Area Alerting 5a4 Subsequent Information & Instmctions 5bl uu I

Reception Center Operations 6al EW Monitoring & Decontamination 6bl Congregate Care 6cl Contaminated Iniured Transport & Care 6dl M

M 15

U nclassificd Radiological Emergency Preparedness Program After Action Report/Improvement Plan 3.3 Criteria Evaluation Summaries 3.3.1 Illinois Jurisdictions 3.3.1.1 State oflllinois - OSF - St. Joseph Medical Center - Medical Service

- Transportation In summary, the status of DHS/FEMA criteria for this location is as follows:

a.

MET: l.e.l, 3.a.l, 6.d.1.

b.

LEVEL 2 FINDINGS: None

c.

LEVEL 1 FINDINGS: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None Clinton Power Station 3.3.1.2 State of Illinois - OSF - St. Joseph Medical Center - Medical Service

  • Facility In summary, the status of DHS/FEMA criteria for this location is as follows:
a.

MET: Le.I, 3.a.1, 6.d.l.

b. LEVEL 2 FINDINGS: None
c.

LEVEL 1 FINDINGS: None

d.

PLAN ISSUES: None

e.

NOT DEMONSTRATED: None

f.

PRIOR ISSUES - RESOLVED: None

g.

PRIOR ISSUES - UNRESOLVED: None 16

Unclassified Radiological Emergency Preparedness Program After Action Report/Improvement Plan Clinton Power Station SECTION 4: CONCLUSION There were no Level 1 Findings, Level 2 Findings or Plan Issues identified as a result of this drill and there were no previous Level 1 Findings, Level 2 Findings or Plan Issues to be con-ected during this drill.

Based on the results of the June 28, 2018 drill, the offsite radiological emergency response plans and preparedness for the State of Illinois and affected local jurisdictions, site-specific to the Clinton Po~er Station, can be implemen~ed and are adequate to provide reasonable assurance that appropriate measure can be taken off site to protect the health and safety of the public in the event of a radiological emergency at the site.

17

Unclassified Radiological Emergency Preparcdnciss Program After Action Report/Improvement Plan Clinton Power Station APPENDIX A: DRILL EVALUATORS AND TEAM LEADERS DATE: 2018-06-28, SITE: Clinton Power Station, IL

,!,~-@ EM~w!Am1D.~

State of Illinois - OSF - St. Joseph Medical Center - Medical Service -. David Ortman*

Trans ortation State oflllinois - OSF - St. Joseph Medical Center - Medical Service -

David Persaud Facili 18

Unclassified Ra~iological Emergency Preparedness Program After Action Report/Improvement Plan Clinton Power Station APPENDIX B: EXERCISE PLAN This appendix lists the exercise criteria, which were scheduled for demonstration in the Medical Services (MS-1) Drill associated with the Clinton Power Station on June 28, 2018 and the offsite extent-of-play agreement acc*epted by DHS/FEMA Region V. The exercise criteria, contained in the DHS/FEMA Radiological Emergency Preparedness (REP) Program Manual, dated January 2018, represent a functional translation of the planning standards and evaluation criteria of NUREG-0654/FEMA-REP-1, Revl, "Criteria for the Preparation and Evaluation of Radiological

  • Emergency Response Plans and Preparedness in Support of Nuclear Power Plants," November 1980. Because the exercise criteria are intended for use at all nuclear power plant sites, and because of variations among offsite plans and procedures, an extent-of-play agreement is prepared by the State and accepted by the DHS/FEMA to provide evaluators with guidance on expected actual demonstration of the criteria.

19

Unclassified

20

Unclassified Radiological Emergency Preparedness Program After Action Report/Improvement Plan Location: OSF St.Joseph's 2200 East Washington Bloomington, IL 61071 Extent of Play Agreement Medical Services Exercise June 28,208 Transportation Provider: Bloomington Fire Ambulance Participant Roster:

Patients #1 Ped #2 Parent #3 Walking Well Lead Controller: IEMA Ambulance Controller: Joni Estabrook Hospital Controller: Tolly Knezevich Float Controller: TBD Radiological Duty Officer (RDO): TBD Clinton Power Station Criteria that can be re--demonstrated immediately for credit at the discretion of the evaluator include the following: For Transportation: l.dl, 3.a.l and 6.d.l; for the Hospital l.dl, Le.I, 3.a.l and 6.d.l. Criteria may be re-demonstrated, as agreed by the Lead Controller and FEMA.

EVALUATION AREAl-EMERGENCY OPERATIONS MANAGEMENT Criterion l.d.l: At least two communication systems are available, at least one operated properly, and communication links are established and maintained with appropriate locations.

The Ambulance will use 2-way radios to communicate with OSF St.Joseph's. Other communication systems that may be used include commercial telephone or cell phones.

Criterion l.e.l: Equipment, maps, displays, dosimetry, potassium iodide (K[) and other supplies are sufficient to support emergency operations.

OSF St.Joseph's will adequately demonstrate the ability to support operations, with adequate resources. OSF St.Joseph's will also issue dosimetry and perform a dosimetry control briefing to staff prior to drill start.

EVALUATION AREA3 - PROTECTIVE ACTION IMPLEMENTATION C1iterion 3.a.l: The ORO's issue appropriate dosimetry, and procedures, and manage radiological e}..1)0sure to emergency workers in accordance with the plan/procedures. Emergency workers periodically and at the end of each mission read their dosimeters and record the readings on the appropriate exposure record or chart.

21

Unclassified Radiological Emergency Preparedness Program After Action Report/Improvement Plan Clinton Power Station EVULAUTION AREA 6.d-1RANSPORTATI0N AND 1REA TMENT OF CONTAMINA 1ED INJURED INVIDUALS Criterion 6.d.l: The facility/ORO has the appropriate space, adequate resources, and tramed personnel to provide transport, monitoring, decontamination, and medical services to contaminated injured individuals.

Extent of Play for OSF St.Joseph's Medical Drill

==

Introduction:==

An off site medical drill will be conducted to demonstrate the State of Illinois' concept of operations of handling contaminated injured individuals. The drill is structured to address MS; 1 Hospital and Transportation Criteria.*

Extent of Play:

The Clinton Nuclear Power Station has declared a general emergency.. The emergency alert sirens have sounded, the public has been directed to evacuate affected areas and to report to reception centers set up in the local area. The scenario is based on a local resident and her daughter who has reported to the reception center from a rural area and spent an extended time in the Clinton EPZ. The drill will begin at the pickup of the patient and parent by the ambulance. Any reception center activities will be observed and evaluated at the reception center demonstration. The walking well patient presenting in registration will be evaluated by the hospital to assist in planning efforts to update the plan.

Hospital and Transportation:

The hospital will demonstrate procedures for limiting exposure to hospital staff, decontaminating a patient, and restricting access to the area where the patient is being treated and monitored.

Bloomington Fire will demo:q.strate the capability.to transport a contaminated, injured individual(s) to OSF St;Joseph's. The ambulance crew \\Vil1. pick up a contaminatedinjured patient near the hospital at a simulated reception center. IEMA staff ¥1ill not initially be available to accompany the ambulance staff during the transportation portion of the drill. IEMAmay be injected after patient arrival should the hospital need and/or request assistance.

Bloomington Fire will call in the information regarding the patient to hospital so they can prepare the receipt of a contaminated injured patient. St.Joseph's will implement th.cir plan for receipt, isolation and treatment of an injured contaminated patient. Medical personnel will utilize universal precautions and good housekeeping practices to minimize the spread of contamination, and will focus on treating the patient's medical condition. Simple decontamination efforts will be demonstrated after the patient has been medically stabilized. The hospital will demonstrate procedures for limiting exposure to hospital staff, decontaminating a patient, and restricting access to the area where the patient is being treated and monitored. Hospital personnel will demonstrate their knowledge of who to call beyond IEMA for assistance in Radiological Accidents, e.g., REAC/TS.

One IEMA Radiological Duty Officer will be available to participate in this drill. The IEMA RDO is available to facilitate hospital staff in monitoring the parent of the patient, ambulance staff and ambulance itself so it can be put baclz into service as soon as possible.

The drill will conclude with hospital nuclear medicine staff supervising the removal of protective clothing and surveying of the emergency room and hospital personnel. The IEMA RDO will be available to facilitate contamination control and decontamination efforts if needed.

IEMA will also advise on the proper procedure for release or disposal of contaminated material 22

Unclassified Radiological Emergency Preparedness Program After Action Rcpmt/1mprovement Plan Clinton Power Station Objectives:

1.

Demonstrate the ability of EMS personnel to transport a contaminated injured patient.

2. Demonstrate the ability of hospital personnel to treat a contaminated injured patient.
3.

Demonstrate the ability of personnel to exercise proper radiological controls and issuance of dosimetry.

4. Demonstrate the proper techniques of personnel decontamination.
5. Demonstrate proper communication between medical personnel and IEMA staff.
6. Demonstrate proper use of radiation detectors.

IEMA Players and Controllers Injured Victim (#1 ped #2 parent #3 walking well)

IEMARDO IEMA Ambulance Controller IEMA Hospital Controller IEMA Float Controller/MRTif needed 23

Unclassified Radiological Emergency Preparedness Program After Action Report/Improvement Plan Clinton Power Station Extent of Play for St.Joseph's Clinton Nuclear Power Station has declared a general emergency. The emergency alert sirens have sounded, the public has been directed to evacuate affected areas and to report to reception centers set up in the local area. The scenario is based on a local resident who had stayed in the EPZ when the release occurred.

This drill will originate near the hospital at a simulated reception center.

1.

An ambulance and EMS staff will be used to demonstrate loading, transporting and unloading the victim. EMS personnel will pick up the patient at a staged location close to the hospital. The patient will be pre--staged for the ambulance arrival. !EMA staff will not be present for the transportation portion of the drill.

2. The ambulance crew will communicate with the receiving hospital regarding the medical status of the patient and any additional precautions taken to prevent spread of contamination.
3.

Hospital nuclear medicine staff will be providing radiological exposure control and monitoring of EMS and hospital persom1el,

4. Decontam.ination is determinant on ambulance protocols and ID jury that the patient presents.
5. Hospital nuclear medicine personnel will be responsible for any patient and staff radiological mmiitoring and contamIDation control activities, duties may change over if IEMA becomes available to be dispatched.
6. The nuclear medicine staff will supervise the ingress and egress of radiological control areas.

MonitorIDg will be performed prior to personnel leaving the potentially contaminated patient treatment area. Protective clothing used by hospital personnel will be similar to that used for a chemical or biological agent in accordance with hospital protocol. Multiple methods of decontamination, including dry, damp or wet, may be. utilized for the removal of contamination.

7.

The medical facility will demonstrate or describe their procedures for the medical treatment and necessary decontammation of a contaminated.injured individual. Multiple methods of decontamination, mcluding dry, damp or wet, may be utilized for the removal of contamination.

Hospital nuclear medicine personnel will survey the hospital REA and medical personnel to maintain contamination control. These methods may.include taking wipes of floors and surfaces so that the hospital and ambulance can be cleared for normal operations.

8.

The hospital may need to contact REAC/TS to determine appropriate samples needed to assess IDternal contarnIDation. Any samples collected will be sent to REAC/TS for analyzing, IEMA does not process biological samples.

C

9.

Emergency medical personnel will be able to maintain their exposure below the limits specified in 10 CFR Part 20 because for the exercise, the dose rate from the patient is below 2 rnr/hr.

10. After the Hospital is notified, hospital personnel will prepare the area to receive the patient ID accordance with their procedures and provide security as necessary. IEMA as a general practice would, if necessary, post radiation signs in accordance with the requirements as set forth in 10 CFR Part 20. Hospital security will control the area ID accordance with the same policies and procedures used to provide isolation in the treatment of a chemkal or biological agent.
11. Regardless of specific writ~en hospital procedures for addressing radiation contamination, the supervision and advice provided by IEMA personnel should be the governing guidance for determining whether the patient's contamination situation is appropriately addressed.
12. The contaminated.injured patient will be accompanied by a parent and mfant that needs to be monitored. The pediatric andmfant decon will be an objective to be performed and evaluated by the hospital, per hospital request.
13. After monitoring and decon has occurred the patient will utilize the decon room for final shower purpose.

The drill terminate when the controller verifies that the criteria under Evaluation Area 6, Sub~element 6.d.l 24

Unclassified Radiological Emergency Preparedness Program After Action Report/Improvement Plan Clinton Power Station and Evaluation Area 3, Sub~element 3.a.l, have been satisfied.

25

Unclassified Radiological Emergency Preparedness Program After Action Report/Improvement Plan O Controller Drill/Exercise Type: OSF St. Joseph's MESSAGE FORM (X) Player Message for: Victim (#1 Ped and #2 Parent) and EMS staff MESSAGE Clinton Power Station TIME: Pre t ~ 0 Victim Instructions

( ) Contingency The Clinton Nuclear Station has issued a public broadcast that a radioactive release has occurred and that the residents and those working or residing in the Clinton EPZ area are being evacuated.

Before evacuating you and your child spend extended time in the EPZ during the release, which delays you in reporting to the reception center. You have been exposed and contaminated with low levels of radioactive materials. Upon arrival at the reception center your daughter falls and starts bleeding in one arm. Your daughter has glass embedded in her wrist limiting the mobility of your fingers. The reception center staff notifies 911.

FOR CONTROLLERS USE ONLY The information would be available to the hospital as they received preliminary notification information from outbound ambulance calls.

26

Unclassified Radiological Emergency Preparedness Program After Action Report/Improvement Plan Clinton Power Station

. TIME: Time 0

  • MESSAGE:

Initial Conditions (X) Controller MESSAGE FORM (X) Player Brill/Exercise Type: OSF St. Toseph's Medical Drill Message for: Hospital Personnel and Nuclear Medicine Staff MESSAGE Initial Conditions:

( ) Contingency

  • Contamination Levels:

Initial FirstDecon Second Decon ThirdDecon survey Reading Right palm**

70Dcpm 500 cpm 300cpm 75cpm Left palm**

600cpm 300cpm 60cpm Pant legs at both knees 500cpm Should be removed Shoes (should be 900cpm 0 should be removed) removed

  • Pant/shoes should be removed and bagged.
  • **Contamination would likely be spread from hand to other parts of the patient's skin or clothing from child to parent. Contamination levels on #:2 Parent will be driven by her interaction with #:1 Ped.

Current Medical Conditions:

Complaining of pain :in wrist, 5 out of 10 scale, conscious, alert pulse present, bleeding or other obvious signs of injury.

FOR CONTROLLERS USE ONLY 27

Unclassified Radiological Emergency Preparedness Program After Action Repmt/Improvemllnt Plan TO:

FROM:

First Responders/EMS EMS Controller Clinton Power Station NOTE: Do not provide the data to players unless the means to obtain it are demonstrated.

IBIS IS A DRILL DO NOT :initiate actions affect:ing safe operations Message: 3 yr old male patient complaining of wrist pain, bleeding and numbness. Patient has allergy to penicillin.

EMS Arrival on Scene Enroute to Hospital InREA Level of ResponsiveX3 consciousness:

Respirations:

24 Pulse:

65 Skin:

Dry Blood Pressure:

140/74 ll0/70 100/68 Visual:

Note:

  • Patient condition en route and :in REA are dependent on EMT actions and level of tra:ining.
  • Allergy to penicillin Expected Action:

Follow local protocols or standing orders.

THIS IS A DRILL DO NOT :initiate actions affecting safe operations 28

Unclassified Radiological Emergency Preparedness Program After Action Repmt/lmprovement Plan (X) Controller MESSAGE FORM (X) Player Drill/Exercise Type: OSF St. Joseph's Medical Drill Message for: Hospital Personnel MESSAGE Clinton Power Station TIME: 0 + 5 min.

MESSAGE: _____

() Contingency When the Hospital is notified that a potentially contaminated patient will be arriving, if the hospital has not already, they should make preparations to receive patient in accordance-with hospital procedures.

FOR CONTROLLERS USE ONLY ED controller may inject, with pennission of Evaluator, a time jump to expedite REA preparedness.

29

Unclassified Radiological Emergency Preparedness Program After Action Rep01t/Improvement Plan TIME: 0 + 15 min.

(X) Controller MESSAGE FORM (X) Player Drill/Exercise Type: OSF St.Joseph's Medical Drill Clinton Power Station MESSAGE: _____

0 Contingency Message for: Hospital Personnel Registration and Walking Well #:3 MESSAGE.

While your sibling and niece were transported to St.Joseph's Medical Center, you followed behind and were unable to be thoroughly surveyed. You present to the registration desk mentioning your sibling and niece were transported from Horton Field House Reception Center.

Contamination Levels Initial Survey FirstDecon Right hand 80cpm 60cpm Shoes 400cpm Contamination removed with removal of shoes Pant legs 300 cpm Contamination removed with doffing of clothing.

FOR CONTROLLERS USE ONLY ED controller may inject, Vilith permission of Evaluator, a time jump to expedite REA preparedness.

30

Unclassified Radiological Emergency Preparedness Program After Action Report/Improvement Plan Clinton Power Station TIME: After patient arrival at hospital MESSAGE: Decontamination Activities (X) Controller MESSAGE FORM

() Player Drill/Exercise Type: OSF St. Joseph's Medical Drill Message for: IEMA RAD Controllers MESSAGE

( ) Contingency If proper radiological controls are in place no contamination is found in the ambulance. All areas of the hospital and path from ambulance to treatment room -will be surveyed and read as background.

The controller may adjust contamination levels based on actions of the players.

The patient has contamination on right palm, left palm, pant lmees and shoes. The parent has contaminated shoes and one contaminated hand that was held by pediatric patient. Contamination levels and locations on parent and infant will be adjusted at the discretion of the controller.

IT DOES NOT MATIER IF THE CLOTHING IS REMOVED BY 1HE AMBULANCE OR HOSPITAL PERSONNEL. Clothing should be bagged and labeled.

FOR CONTROLLERS USE ONLY 31

U ncfassified Radiological Emergency Preparedness Program After Action Report/Improvement Plan Clinton Power Station This page is intentionally blank.