ML18271A153

From kanterella
Jump to navigation Jump to search
C. Jones Presentation: NRCs Radiation Protection Policy - What Does It Take for Change? at the ANS-HPS Joint Topical Meeting in Tri-Cities, Wa - October 2018
ML18271A153
Person / Time
Issue date: 10/11/2018
From: Clint Jones
NRC/RES/DSA
To:
Jones C
References
Download: ML18271A153 (17)


Text

NRCs Radiation Protection Policy -

What Does it Take for Change?

Cynthia G. Jones, Ph.D.

U.S. Nuclear Regulatory Commission Office of Nuclear Regulatory Research 1

ANS-HPS Topic Meeting, October 1, 2018

Overview

  • Key Milestones for Radiation Protection Policy
  • Below Regulatory Concern (BRC) Policy Statements
  • Is LNT the Issue? Options for Licensees
  • Exploring Case Studies
  • LNT & ALARA: Why go beyond ALARA?
  • External influencing factors
  • Impacts
  • Thoughts for the Future 2

ANS-HPS 2018 Topical Meeting, October 1, 2018

Key Milestones*

NRC Radiation Protection Policy 1957: Atomic Energy Commission issues 10 CFR Part 20 1977: ICRP 26 published 1980: BEIR III issued 1980: NRC issues an Advanced Notice of Proposed Rulemaking 1986: NRC issues proposed Part 20 changes 1987: NCRP issues Report 91 1990: NRC Below Regulatory Concern Policy Statement issued 199o-1: ICRP Report 60 issued 1991: NRC issues its revised Part 20 updating it to ICRP 26 & 30 2007: ICRP issues Report 103 2009: NRC: stakeholder outreach to update Part 20 & Part 50, App. I 2016: NRC discontinues Part 20 & Part 50, App. I rulemakings 3

ANS-HPS 2018 Topical Meeting, October 1, 2018

  • See also Health Phys. 88(2): 105-124; 2005

The Below Regulatory Concern (BRC)

Policy Statements NRC issued two BRC policy statements :

- 1986: Radioactive Waste BRC

- 1990: BRC Policy Statement for a consistent risk framework Low-Level Radioactive Waste Policy Amendments Act of 1985 1991: NRC issues indefinite moratorium on use of the statements 1992: Energy Policy Act of 1992 revoked the 1986 and 1990 BRC policy statements 1993: Formal withdrawals of BRC Policy Statements and related rulemaking which would have implemented the 1986 BRC Waste Statement NRC continues to issue exemptions on a case-by-case basis 4

ANS-HPS 2018 Topical Meeting, October 1, 2018

Evolving NRC Policy 2009-12: NRC engaged in extensive stakeholder outreach to update Part 20 & Part 50, App. I to reach alignment with ICRP 103 2012: NRC Commission direction (SECY-12-0064):

- Update methodology and terminology to align with ICRP 103

- Develop improvements for effective implementation of ALARA

- Continue discussions for dose limits to the lens of the eye & embryo/fetus

- Disapproved reduction of dose limits from 50 mSv/y to 20 mSv/y

- Disapproved SI units

- Improve reporting of occupational exposure 2014: Advanced Notice of Proposed Rulemaking for Part 20 2015: Advanced Notice of Proposed Rulemaking for Part 50, App I SECY-16-0009: Recommendation to discontinue rulemaking Dec 2016: NRC discontinues Part 20 & Part 50, App. I rulemakings 5

ANS-HPS 2018 Topical Meeting, October 1, 2018

Is LNT the issue?

What are the Options for Licensees?

Case studies:

1. Petition for rulemaking
2. Request an exemption
3. ALARA & Decommissioning 6

ANS-HPS 2018 Topical Meeting, October 1, 2018

Ex 1: Petition for Rulemaking

  • 2015: NRC received 3 similar petitioner requests* to amend Part 20 with regard to the LNT hypothesis (80 FR 35870 )
  • Petitioners assert that valid scientific studies and evidence exist that contradicts LNT hypothesis
  • Petitioners recommend

- Workers effective doses up to 100 mSv (10 rem) per year if chronic

- Removal of ALARA from the regulations, as it makes no sense to decrease radiation doses that are not only harmless, but may be hormetic

- Raise public dose limits to same level as worker dose limits, as these low doses may be hormetic

- End differing doses limits for pregnant women, embryos and fetuses, and children under 18 years of age 7

  • PRM-20-28, PRM-20-29 and PRM-20-30 ANS-HPS 2018 Topical Meeting, October 1, 2018

Current Status of LNT Petitions

  • >3,200 public comment letters received
  • NCRP Commentary 27* issued in April 2018:

- Review of recent epidemiologic studies support the continued use of the LNT model for radiation protection

- Concluded that no alternate dose-response relationship appears better than LNT

  • Currently developing a Commission paper for a decision on petitioners requests 8

ANS-HPS 2018 Topical Meeting, October 1, 2018

  • NCRP Commentary 27, Implications of Recent Epidemiologic Studies for the Linear-Nonthreshold Model and Radiation Protection

Ex 2: Exemptions NRC receives and has approved many exemptions to Part 20 based on justification. Examples include:

- SECY-99-077: Approval for a Th licensee to use alternate ICRP internal dosimetry models (ICRP 68); and to approve future exemptions, case-by-case (e.g., fuel cycle facilities)

- SECY-99-136: Exemptions granted to transfer baghouse slag containing <0.05 wt% source material to exempt persons if doses were less than 1 mSv/y (NRC notification if >0.25 mSv)

- SECY-01-0148 : Continuance to consider and grant licensee requests to use the ICRP revised internal dosimetry models on a case-by-case basis 9

ANS-HPS 2018 Topical Meeting, October 1, 2018

Ex 3: ALARA & Decommissioning Current 1997 decommissioning regulations are performance-based and risk-informed:

- NRC terminates ~100 materials licenses/y

- NUREG-1757, V2, R1: Decommissioning Guidance

- Reasonable land use

- Flexibility: screening vs site-specific dose assessment

- No calculations needed for ALARA (App N)

- No need to go below the regulatory limits

- Requests for exemptions (e.g., ICRP 26 72)

- 2002 NRC-EPA MOU: facilitates decision-making 10 ANS-HPS 2018 Topical Meeting, October 1, 2018 See www.nrc.gov/waste/decommissioning.html

LNT & ALARA

  • 10 CFR 20.1101(b) - implementation of ALARA

- Because of the..absence of scientific certainty regarding the relationship between low doses and health effects, LNT is used as a conservative assumption for radiation protection purposes

  • ALARA is intended to be an operating principle rather than an absolute minimization of exposures
  • What pushes licensees to go beyond ALARA?

11 ANS-HPS 2018 Topical Meeting, October 1, 2018

Why go beyond ALARA?

ALARA: making a reasonable effort to maintain exposures as far below the limit as is practical

  • But licensees have many external factors:

NRC as the regulator Stakeholder questions/concerns Other Federal or State regulations Accreditation requirements Insurance requirements Peer pressure to lower doses 12 ANS-HPS 2018 Topical Meeting, October 1, 2018

Where do we go from here?

13 ANS-HPS 2018 Topical Meeting, October 1, 2018

UNSCEAR 2015 Report Attributing Health Effects to Ionizing Radiation Exposure and Inferring Risks

  • UNSCEAR highlights the concepts of attributability, inference of risk, and use of collective dose which could impact Justification Optimization Graded approach Low doses and associated uncertainties The LNT hypothesis & its use in the safety standards Challenges in communicating radiation benefits and risks 14 ANS-HPS 2018 Topical Meeting, October 1, 2018

Impacts

  • Regulatory agencies make changes based upon science, national and international recommendations, and in the U.S., the participatory rulemaking process
  • Stakeholder engagement & communication support are needed for paradigm shift
  • Educate external influences for a moderate approach
  • Focus on the facts that NRC regulations do allow for flexibility to:

- Use risk-informed, performance based approaches for implementation

- Request exemptions to use new models/methodology 15 ANS-HPS 2018 Topical Meeting, October 1, 2018

Thoughts for the Years Ahead Completion of the health risk assessment from low-dose/

dose rates (Million Worker Study)

Improving realism in dose assessment Use the UNSCEAR concepts of attribution in practice Use of ALARA as designed Strong scientific support for a different dose-response relationship For change to occur there must be international and national consensus 16 ANS-HPS 2018 Topical Meeting, October 1, 2018

17 Thank you!

For further information, contact:

cynthia.jones@nrc.gov www.nrc.gov