ND-18-1208, ITAAC Closure Notification on Completion of ITAAC 2.2.03.08c.v.01 (Index Number 187)
| ML18268A109 | |
| Person / Time | |
|---|---|
| Site: | Vogtle |
| Issue date: | 09/24/2018 |
| From: | Yox M Southern Nuclear Operating Co |
| To: | Document Control Desk, Office of New Reactors |
| References | |
| ITAAC 2.2.03.08c.v.01, ND-18-1208 | |
| Download: ML18268A109 (7) | |
Text
^
Southern Nuclear Michael J. Yox Regulatory Affairs Director Vogtle 3 &4
Enclosure:
Vogtle Electric Generating Plant (VEGP) Unit 3 Completion of ITAAC 2.2.03.08c.v.01 [Index Number 187]
MJY/GDL/amw Michael J. Yox 7825 River Road Regulatory Affairs Director Waynesboro, GA 30830 Vogtle 3 &4 706-848-6459 tet 410-474-8587 cell SEP 2 I, 2018 myox@southernco.com Docket Nos.:
52-025 ND-18-1208 10CFR 52.99(c)(1)
U.S. Nuclear Regulatory Commission Document Control Desk Washington, DC 20555-0001 Southern Nuclear Operating Company Vogtle Electric Generating Plant Unit 3 ITAAC Closure Notification on Completion of ITAAC 2.2.03.08c.v.01 llndex Number 1871 Ladies and Gentlemen:
Inaccordance with 10 CFR 52.99(c)(1), the purpose of this letter is to notify the Nuclear Regulatory Commission (NRC) ofthe completion of Vogtle Electric Generating Plant (VEGP) Unit 3 Inspections, Tests, Analyses, and Acceptance Criteria (ITAAC) Item 2.2.03.08c.v.01 [Index Number 187] for verifying that the elevation ofthe bottom inside tank surface ofthe Core Makeup Tanks (CMTs) is higher than the direct vessel injection nozzle centerlines bygreaterthan or equalto 7.5ft.
The closure process for this ITAAC is based on the guidance described in NEI 08-01, "Industry Guideline for the ITAAC Closure Process under 10 CFR Part 52," which was endorsed by the NRC in Regulatory Guide 1.215.
This letter contains no new NRC regulatory commitments. Southern Nuclear Operating Company (SNC) requests NRC staffconfirmation ofthis determination and publication ofthe required notice in the Federal Register per 10 CFR 52.99.
If there are any questions, please contact Tom Petrak at 706-848-1575.
Respectfully submitted.
f-s ^
U.S. Nuclear Regulatory Commission ND-18-1208 Page 2 of 3 To:
Southern Nuclear Operating ComDanv/ Georgia Power Company Mr. D. A. Bost (w/o enclosures)
Mr. M. D. Rauckhorst (w/o enclosures)
Mr. M. D. Meier Mr. D. H. Jones (w/o enclosures)
Mr. D. L. McKinney Mr. M. J. Vox Mr. D. L. Fulton Mr. J. B. Klecha Mr. G. Chick Mr. F. H. Willis Ms. A. L. Pugh Mr. A. 8. Parton Mr. W. A. Sparkman Mr. C. E. Morrow Ms. K. M. Stacy Mr. M. K. Washington Mr. J. P. Redd Ms. A. C. Chamberlain Mr. D. R. Culver Mr. T. G. Petrak Document Services RTYPE: VND.LI.L06 File AR.01.02.06 cc:
Nuclear Regulatory Commission Mr. W. Jones (w/o enclosures)
Ms. J. M. Heisserer Mr. C. P. Patel Mr. M. E. Ernstes Mr. G. J. Khouri Mr. T. E. Chandler Ms. S. E. Temple Ms. P. Braxton Mr. N. D. Karlovich Mr. A. J. Lerch Mr. C. J. Even Mr. F. D. Brown Mr. B. J. Kemker Ms. A. E. Rivera-Varona Ms. L. A. Kent Mr. P. B. Donnelly Ms. N. C. Coovert Oalethoroe Power Corporation Mr. R. B. Brinkman
U.S. Nuclear Regulatory Commission ND-18-1208 Page 3 of 3 Municipal Electric Authority of Georgia Mr. J. E. Fuller Mr. 8. M. Jackson Dalton Utilities Mr. T. Bundros Westinqhouse Electric Company. LLC Dr. L. Oriani (w/o enclosures)
Mr. D. 0. Durham (w/o enclosures)
Mr. M. M. Corletti Ms. L. G. Iller Mr. D. Hawkins Ms. J. Monahan Mr. J. L. Coward Ms. N. E. Deangelis Other Mr. J. E. Hosier, Bechtel Power Corporation Ms. L. Matis, Tetra Tech NUS, Inc.
Dr. W. R. Jacobs, Jr., Ph.D., CDS Associates, Inc.
Mr. 8. Roetger, Georgia Public Service Commission Ms. 8. W. Kernizan, Georgia Public Service Commission Mr. K. C. Greene, Troutman Sanders Mr. 8. Blanton, Balch Bingham
U.S. Nuclear Regulatory Commission ND-18-1208 Enclosure Page 1 of 3 Southern Nuclear Operating Company ND-18-1208 Enclosure Vogtle Electric Generating Plant (VEGP) Unit 3 Completion of ITAAC 2.2.03.08c.v.01 [Index Number 187]
U.S. Nuclear Regulatory Commission ND-18-1208 Enclosure Page 2 of 3 ITAAC Statement Design Commitment 8.c)
The PXS provides RCS makeup, boration, and safety injection during design basis events.
Insoections/Tests/Analvses v)
Inspections ofthe elevation of the following tanks will be conducted:
1.CMTS Acceptance Criteria v)
The elevation ofthe bottom insidetank surface is higherthan the directvessel injection nozzle centerline by the following:
1.CMTs> 7.5 ft ITAAC Determination Basis Multiple ITAAC are performed to demonstratethat the Passive Core Cooling System (PXS) provides Reactor Coolant System (RCS) makeup, boration, and safetyinjection during design basis events. This ITAAC requires that inspections be conducted to verify that the elevation of the Core MakeupTanks (CMTs) bottom insidetank surface is higherthan the direct vessel injection nozzle centerline by s 7.5 ft.
The inspection ofthe bottom insidetank surface of both CMTs (SV3-PXS-MT-02A and -02B) and their associated direct vessel injection nozzle centerlines was performed using survey equipment in accordance with site survey and measurement procedures (Reference 1).
Additionally, calculations, based upon as-built manufacturer's data, combined with field measurements were used to determine the elevation of the bottom inside surfaces of each tank.
The derived elevation of the bottom inside tank surface of each CMT was compared to the measured elevation of their associated direct vessel injection nozzle centerline using a common reference point.
The inspection results are documented in Reference 2. The results determined that the elevation of the bottom inside tank surface of CMT SV3-PXS-MT-02A and SV3-PXS-MT-02B is 107.09 feet and 107.13 feet, respectively and the elevation of their associated direct vessel injection nozzle centerlines is 99.58 feet and 99.57 feet, respectively. These inspection results verify thatthe elevation ofthe bottom inside tank surface ofCMT SV3-PXS-MT-02A and -02B is 7.5 ft and 7.6 ft higherthan the elevation oftheir associated respective directvessel injection nozzle centerlines, which meets the ITAAC acceptance criteria.
U.S. Nuclear Regulatory Commission ND-18-1208 Enclosure Page 3 of 3 ITAAC Finding Review In accordance with plant procedures for ITAAC completion, Southern Nuclear Operating Company (SNC) performed a reviewof all ITAAC findings pertaining to the subject ITAAC and associated corrective actions. This review found that there are no relevant ITAAC findings associated with this ITAAC. The ITAAC completion review is documented in the ITAAC Completion Package for ITAAC 2.2.03.08c.iv.01 (Reference 3) and available for NRC review.
ITAAC Completion Statement Based on the above information, SNC hereby notifies the NRC that ITAAC 2.2.03.08c.v.01 was performed for VEGP Unit3 and that the prescribed acceptance criteria are met.
Systems, structures, and components verified as part of this ITAAC are being maintained in their as-designed, ITAAC compliantcondition inaccordance with approved plant programs and procedures.
References (available for NRC Inspection)
- 1. 26139-000-4MP-T81C-N3201 Vogtle Units 3 and 4 Construction Completion Project -
Construction Survey 2.
SV3-PXS-MTK-892047 Rev 2, "CMT's Bottom Inside Tank Surface Comparison to DVI Nozzle Centerline Elevation" 3.
2.2.03.08c.v.01-U3-CP-Rev 0, ITAAC Completion Package