L-MT-18-051, Supplement to License Amendment Request to Revise Technical Specifications to Adopt TSTF-542, Reactor Pressure Vessel Water Inventory Control,
| ML18254A046 | |
| Person / Time | |
|---|---|
| Site: | Monticello (DPR-022) |
| Issue date: | 09/11/2018 |
| From: | Murphy M Northern States Power Co, Xcel Energy |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| EPID L-2017-LLA-0360, L-MT-18-051 | |
| Download: ML18254A046 (4) | |
Text
2807 West County Road 75 Monticello, MN 55362 800.895.4999 xcelenergy.com September 11, 2018 L-MT-18-051 10 CFR 50.90 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Monticello Nuclear Generating Plant Docket No. 50-263 Renewed Facility Operating License No. DPR-22 Supplement to License Amendment Request to Revise Technical Specifications to Adopt TSTF-542, Reactor Pressure Vessel Water Inventory Control, (EPID: L-2017-LLA-0360)
References:
- 1) Letter from NSPM to the NRC, Application to Revise Technical Specifications to Adopt TSTF-542, Reactor Pressure Vessel Water Inventory Control, dated October 20, 2017 (ADAMS Accession Number ML17293A280)
- 2) Letter from NSPM to the NRC, Response to Request for Additional Information Regarding Application to Revise Technical Specifications to Adopt TSTF-542, Reactor Pressure Vessel Water Inventory Control, and Supplement (EPID: L-2017-LLA-0360), dated June 1, 2018 (ADAMS Accession Number ML18157A056)
By letter dated October 20, 2017, (Reference 1), Northern States Power Company, a Minnesota Corporation, doing business as Xcel Energy (hereafter NSPM), submitted a license amendment request (LAR) to adopt TSTF-542, Reactor Pressure Vessel Water Inventory Control, for the Monticello Nuclear Generating Plant (MNGP). By letter dated June 1, 2018, (Reference 2) NSPM submitted both a response to an NRC Request for Additional Information (RAI) and a supplement to the LAR. The supplement portion of Reference 2 addressed minor errors and opportunities for clarification, which had been identified subsequent to the submittal of the LAR.
For Enclosure 2, item 3, of Reference 2, the resolution had been developed by the Boiling Water Reactors Owners Group (BWROG). The BWROG recommended action was for licensees to consider taking a variation from the TSTF to affix footnote (a) to the Required Channels per Function column for Functions 1.a and 2.a of the TS RPV Water Inventory Control Instrumentation table (MNGP TS Table 3.3.5.3-1 located on TS page 3.3.5.3-3).
NSPM had intended to adopt the BWROG variation and provided a marked-up TS page 3.3.5.3-3 containing a modified TS Table 3.3.5.31. However, contrary to the BWROG fl Xcel Energy*
RESPONSIBLE BY NATURE
Document Control Desk Page 2 variation, NSPM erroneously affixed footnote (a) to Functions 1.a and 2.a in the "Applicable Modes or Other Specified Conditions" column. Therefore, this supplement corrects the error and aligns the MNGP TS Table 3.3.5.3-1 with the BWROG recommended action by affixing footnote (a) correctly to the "Required Channels per Function" column, as was originally intended.
The NSPM has reviewed the No Significant Hazards Consideration determination provided in the LAR (Reference 1) and determined that it is unaffected and still applicable with the inclusion of the change. The Enclosure to this letter provides the re-typed TS page 3.3.5.3-3.
Summary of Commitments This letter makes no new commitments and no revisions to existing commitments.
I declare under penalty of perjury, that the foregoing is true and correct.
Executed on September 11, 2018.
!:i~S~t;P41 Director, Nuclear Licensing and Regulatory Services Northern States Power Company - Minnesota Enclosure cc:
Administrator, Region Ill, USNRC Project Manager, Monticello, USNRC Resident Inspector, Monticello, USNRC State of Minnesota
ENCLOSURE MONTICELLO NUCLEAR GENERATING PLANT Supplement to License Amendment Request to Adopt TSTF-542, Reactor Pressure Vessel Water Inventory Control TECHNICAL SPECIFICATION PAGE (Re-typed)
(1 Page Follows)
RPV Water Inventory Control Instrumentation 3.3.5.3 Monticello 3.3.5.3-3 Amendment No. XXX Table 3.3.5.3-1 (page 1 of 1)
RPV Water Inventory Control Instrumentation FUNCTION APPLICABLE MODES OR OTHER SPECIFIED CONDITIONS REQUIRED CHANNELS PER FUNCTION CONDITIONS REFERENCED FROM REQUIRED ACTION A.1 SURVEILLANCE REQUIREMENTS ALLOWABLE VALUE
- 1. Core Spray System
- a.
Reactor Steam Dome Pressure - Low (Injection Permissive) 4, 5 2(a)
C SR 3.3.5.3.2 397 psig and 440psig
- 2. Low Pressure Coolant Injection (LPCI) System
- a.
Reactor Steam Dome Pressure -
Low (Injection Permissive) 4, 5 2(a)
C SR 3.3.5.3.2 397 psig and 440 psig
- b.
Low Pressure Coolant Injection Pump Discharge Flow - Low (Bypass) 4, 5 1 per pump(a)
D SR 3.3.5.3.2 360 gpm and 745 gpm
- 3. Shutdown Cooling System Isolation
- a.
Reactor Vessel Water Level - Low (b) 2 in one trip system B
SR 3.3.5.3.1 SR 3.3.5.3.2 7 inches
- 4. Reactor Water Cleanup (RWCU) System Isolation
- a.
Reactor Vessel Water Level - Low Low (b) 2 in one trip system B
SR 3.3.5.3.1 SR 3.3.5.3.2
-48 inches (a) Associated with an ECCS subsystem required to be OPERABLE by LCO 3.5.2, "Reactor Pressure Vessel (RPV)
(b) When automatic isolation of the associated penetration flow path(s) is credited in calculating DRAIN TIME.