ML18250A113
| ML18250A113 | |
| Person / Time | |
|---|---|
| Site: | Aerotest |
| Issue date: | 05/17/1965 |
| From: | Newacheck R Aerojet-General Nucleonics |
| To: | Boyd R US Atomic Energy Commission (AEC) |
| References | |
| Download: ML18250A113 (3) | |
Text
.~
.t,t*-****
AGNI A E R O J E T - G E *N.E R A L. N U C L E O N I C S P.O. BOX 77, SAN RAMON, CALIFORNIA, 94583
- AREA CODE 415
- 837-5311 May 17, 1965 Roger S. Boyd, Chief Research & Power Reactor Safety Branch Di vision of Reactor Licensing
~~
U. S. Atomic Energy* Commission,
~-
Washington, D. C.
20545
Subject:
AEC Docket No. 50-228
Reference:
.AEC letter dated May 7, 1965, same subject
Dear Mr. Boyd:
Aerojet-General Nucleonics has reviewed the draft Technica_l Specifications for.the AGN Industrial Reactor (AGNIR) prepared by your staff and forwarded to AGN by.the reference letter. AGN is in agreement with your draft of the Technical Specifications subject to the following changes which were mutually.
agreed upon with Mr. Brian Grimes in a May 14, 1965 telephone conversation.
- 4. 2. 7(3)
- 5. 1. 1
- 7. 5. 1
- 8. 2. 1 8.3. 1
- 8. 7. 1
- 9. 2. 1 The maximum burnable poison reactivity worth be increased to
- 2. 25 dollars to be consistent with the maximum number of fuel elements in the reactor core (90).
In the first sentence, the words "consist of" be replaced by
- 11include" as recommended by Mr. Grimes.
Add to this sentence "in the active core region."
Change _the second sentence to read as follows: "Any changes affecting the safety of the reactor as well as *** 11 Change the second sentence to read: "Any changes in the methods of handling radioisotopes *** 11 In.the second sentence, delete the words 11with a copy to the Deputy Reactor Supervisor;" as suggested by* Mr. Grimes.
- Change the fir st sentence to read:
11 *** material installed in or near the core region *** 11 as suggested by Mr. Grimes.
A 5
U B 5 I D I A R Y O
F A E R O J E T -
G E N E R A L C
O R
P O R A T I O N *~E*:.::*;i
- 1831
Roger S *. Boyd
- 9. 3. 1. 2
- 9. 5.-1
- 9. 5. 2 10.6 Table 1
... z_
May 17, 1965
- Replace 11at least once each week *** 11 with "at least once each month *** 11 Change the first sentence to read: "All fuel transfers within the reactor* tank shall be conducted *** 11 Add an
- additional sentence to the paragraph to read:
11Fuel transfers outside the reactor tank but within.the facility shall be supervised bya*licensed operator."
Delete 110nly one fuel storage pit shall be opened at one time. 11 Change the first sentence to read: "All instrument channels and radiation monitors shall be calibrated *** " as suggested by Mr. -Grimes.
Both foot notes shall be modified by replacing 116 x 10-ll amps" with "*a fixed setting.. ii It is assumed that the above will permit-your final action on the AGNIR Technical Specifications.,
Very truly yours, AEROJET -GENERAL NUCLEONICS
~~~7>:~
ewacheck, Manager Techn:ical Services*,Division RLN:RLT:jb
AG N I
~ :*~~ ~. ~.E:~~-~~,:~.:.~E-~~-~ Cs 7600:RLN Developers of COMPACT. NUCLEAR PO'NER SYSTEMS Roger S. Boyd, Chief Research & Power Reactor Safety Branch Di vision of Reactor Licensing U. S. Atomic. Energy Commission Washington, D. C.
20545