ML18243A176

From kanterella
Jump to navigation Jump to search

Enclosure 1: CoC No. 5797, Rev. No. 20 (Letter to J. Shuler Revision No. 20 Certificate of Compliance No. 5797)
ML18243A176
Person / Time
Site: 07105797
Issue date: 08/31/2018
From: John Mckirgan
Spent Fuel Licensing Branch
To: Shuler J
US Dept of Transportation (DOT)
Lingam S
Shared Package
ML18243A175 List:
References
EPID L-2018-LLA-0213
Download: ML18243A176 (3)


Text

NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1.
a. CERTIFICATE NUMBER
b. REVISION NUMBER
c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER PAGE PA GE 5797 20 71-5797 USA/5797/B(U)F 1

OF 3

2. PREAMBLE
a. This certificate is issued to certify that the package (packaging and contents) described in Item 5 below meets the applicable safety standards set forth in Title 10, Code of Federal Regulations, Part 71, Packaging and Transportation of Radioactive Material.
b. This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.
3.

THIS CERTIFICATE IS ISSUED ON THE BASIS OF A SAFETY ANALYSIS REPORT OF THE PACKAGE DESIGN OR APPLICATION

a.

ISSUED TO (Name and Address)

b. TITLE AND IDENTIFICATION OF REPORT OR APPLICATION U.S. Department of Energy Washington, D.C. 20585 U.S. Department of Energy application dated May 30, 1991, as supplemented
4. CONDITIONS This certificate is conditional upon fulfilling the requirements of 10 CFR Part 71, as applicable, and the conditions specified below.
5.

(a) Packaging (1)

Model No.: Inner HFIR Unirradiated Fuel Element Shipping Container, and Outer HFIR Unirradiated Fuel Element Shipping Container (2)

Description Packaging for unirradiated fissile radioactive material as fuel elements for the High Flux Isotope Reactor (HFIR). The containers are right circular cylinders with an 11-gauge carbon steel shell. The lid is attached to the container with sixteen 3/8-16x1-inch steel bolts. The steel shell is filled with stacked fir plywood rings.

The plywood rings form a central cavity which is lined with 1-inch thick polyethylene foam.

The packaging for the inner HFIR fuel element has overall dimension of 25 inches OD by 45 inches high, a 10-7/8-inch diameter by 30-1/4-inch deep cavity, and a 660 pound gross weight.

The packaging for the outer HFIR fuel element has overall dimensions of 31.5 inches OD by 45.75 inches high, a 17-3/8-inch diameter by 31-1/8-inch deep cavity, and a 1,050 pound gross weight.

(3)

Drawings (i)

The packaging for the inner HFIR fuel is constructed in accordance with Oak Ridge National Laboratory Drawing Nos. M-20978-EL-003E, Rev. F, and M-20978-EL-008E, Rev. C.

NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1.
a. CERTIFICATE NUMBER
b. REVISION NUMBER
c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 5797 20 71-5797 USA/5797/B(U)F 2

OF 3

5.

(a)

(3)

Drawings (continued)

(ii)

The packaging for the outer HFIR fuel is constructed in accordance with Oak Ridge National Laboratory Drawing Nos. M-20978-EL-002E, Rev. E, and M-20978-EL-008E, Rev. C.

(b)

Contents (1)

Type and form of material Uranium as U3O8-Al cermet, enriched up to 95% in the U-235 isotope, and clad in aluminum, 10-mils thick, and:

(i)

For the packaging described in 5(a)(3)(i), the contents are described in ORNL/RRD/INT-37-V3, Specification for High Flux Isotope Reactor Fuel Elements RRD-FE-3, Revision 4, and in the following Oak Ridge National Laboratory Drawing Nos.: E-42118, Rev. R; E-42112, Rev. H; D-42113, Rev. G; D-42114, Rev. K; and E-42117, Rev. H.

(ii)

For the packaging described in 5(a)(3)(ii) the contents are described in ORNL/RRD/INT-37-V3, Specification for High Flux Isotope Reactor Fuel Elements RRD-FE-3, Revision 4, and in the following Oak Ridge National Laboratory Drawing Nos.: E-42126, Rev. N; E-42120, Rev. H; D-42121, Rev. H; D-42122, Rev K; and E-42125, Rev. J.

(2)

Maximum quantity of material per package (i)

For the contents described in 5(b)(1)(i) not more than 2.63 kg of U-235.

(ii)

For the contents described in 5(b)(1)(ii) not more than 6.88 kg of U-235.

(c)

Criticality Safety Index 0.4

6.

The lid lifting attachments must be blocked as shown on Oak Ridge National Laboratory Drawing No. M-20978-EL-009E, Rev. 2, to prevent inadvertent use of the attachments during transport.

NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES

1.
a. CERTIFICATE NUMBER
b. REVISION NUMBER
c. DOCKET NUMBER
d. PACKAGE IDENTIFICATION NUMBER PAGE PA GE 5797 20 71-5797 USA/5797/B(U)F 3

OF 3

7.

In addition to the requirements of Subpart G of 10 CFR Part 71:

(a)

Each package shall be maintained in accordance with the Maintenance Program in Chapter 8 of the application; (b)

Each package shall be operated and prepared for shipment in accordance with the Operating Procedures in Chapter 7 of the application; and (c)

The fuel element shall meet the fabrication inspection requirements of ORNL/RRD/INT V3, Specification for High Flux Isotope Reactor Fuel Elements RRD-FE-3, Revision 4.

8.

Use of packaging fabricated after December 31, 1976, is not authorized.

9.

The packaging authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 71.17.

10.

Transport by air of fissile material is not authorized.

11.

Expiration date: October 31, 2022.

REFERENCES U.S. Department of Energy Application dated May 30, 1991.

Supplements dated: February 26, 1992; April 2, 1993; September 23, 1996; September 2, 1998; February 24, 2000; February 4, 2002; August 20, 2007; and October 29, 2007; June 28, 2012; June 27, 2017, and July 30, 2018.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION

/RA/

John McKirgan, Chief Spent Fuel Licensing Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards Date: 8/31/18