ML18240A068

From kanterella
Jump to navigation Jump to search
Global Nuclear Fuel - Americas, LLC - Semi-Annual Effluent Report -January 2018 - June 2018
ML18240A068
Person / Time
Site: 07001113
(SNM-1097)
Issue date: 08/28/2018
From:
Global Nuclear Fuel
To:
Office of Nuclear Material Safety and Safeguards
Shared Package
ML18240A066 List:
References
M180178
Download: ML18240A068 (1)


Text

SEMI-ANNUAL EFFLUENT REPORT Global Nuclear Fuel - Americas, LLC Wilmington, North Carolina NRC License SNM 1097, Docket# 70-1113 I.

GASEOUS EFFLUENT-PARTICULATE NUCLIDES QUANTITY CONCENTRATION (Ci)

(uCi/cc)

U234 9.03E-06 4.84E-15 U235 3.81E-07 2.04E-16 U236 2.86E-09 1.53E-18 U238 1.35E-06 7.23E-16 TOTAL 1.08E-05 "APPENDIXB LIMIT

%of LIMIT (uCi/cc) 5 E-12 0.10%

6 E-12 0.00%

6 E-12 0.00%

6 E-12 0.01%

EXHAUST VOLUME =

1.87E+15 (cc)

II.

LIQUID EFFLUENT NUCLIDES QUANTITY CONCENTRATION (Ci)

(uCi/cc)

U234 3.41 E-03 1.62E-08 U235 1.44E-04 6.81E-10 U236 1.08E-06 5.12E-12 U238 5.09E-04 2.42E-09 TOTAL U 4.06E-03 TOTAL VOLUME OF LIQUID EFFLUENT=

Ill. ABNORMAL RELEASES

  1. Releases Activity Released (Ci)

IV.

SUMMARY

IValue Limit

%of Limit Air 0

0

    • Max Release (uCi/cc) 1.62E-08 3.00E-07 5.39%

Water 0

0 CEDE, total (mrem) 2.81E-02 25 0.11%

"APPENDIX B LIMIT

%of LIMIT (uCi/cc) 3 E-07 5.39%

3 E-07 0.23%

3 E-07 0.00%

3 E-07 0.81%

2.11 E+08 (litres)

Total 0

0 CDE (Lung), total (mrem) 2.36E-01 25 0.94%

CEDE mrem 2.42E-02 8.56E-04 6.43E-06 3.04E-03 2.81E-02 CEDE (mrem) 1.18E-06 7.09E-08 3.53E-10 1.59E-07 1.41E-06 January 2018 -June 2018 Fiscal Weeks 1-26 CDE (Lung) mrem 2.03E-01 7.14E-03 5.36E-05 2.53E-02 2.36E-01 CDE (Bone CDE (Lung)

Surface)

(mrem)

(mrem) 7.44E-07 1.71E-05 4.50E-08 1.03E-06 2.25E-10 5.12E-09 1.01E-07 2.31E-06 8.90E-07 2.05E-05

  • Limit from 10 CFR 20 Appendix B, Table 2, Columns 1 and 2. Air limit adjusted to reflect NRC License SNM-1 097, Section 1.3.9.
    • From nuclide with release that is the largest percentage of its release limit.

NOTES:

Air sampling is continuous. Water samples analyzed are representative, continuous composite samples of the process effluent stream.

Reported effluent concentration values are representative of the effluent concentration at the point of release and do not consider effects of dilution from point of release to the plant site boundary.