SEMI-ANNUAL EFFLUENT REPORT Global Nuclear Fuel - Americas, LLC Wilmington, North Carolina NRC License SNM 1097, Docket# 70-1113 I.
GASEOUS EFFLUENT-PARTICULATE NUCLIDES QUANTITY CONCENTRATION (Ci)
(uCi/cc)
U234 9.03E-06 4.84E-15 U235 3.81E-07 2.04E-16 U236 2.86E-09 1.53E-18 U238 1.35E-06 7.23E-16 TOTAL 1.08E-05 "APPENDIXB LIMIT
%of LIMIT (uCi/cc) 5 E-12 0.10%
6 E-12 0.00%
6 E-12 0.00%
6 E-12 0.01%
EXHAUST VOLUME =
1.87E+15 (cc)
II.
LIQUID EFFLUENT NUCLIDES QUANTITY CONCENTRATION (Ci)
(uCi/cc)
U234 3.41 E-03 1.62E-08 U235 1.44E-04 6.81E-10 U236 1.08E-06 5.12E-12 U238 5.09E-04 2.42E-09 TOTAL U 4.06E-03 TOTAL VOLUME OF LIQUID EFFLUENT=
Ill. ABNORMAL RELEASES
- Releases Activity Released (Ci)
IV.
SUMMARY
IValue Limit
%of Limit Air 0
0
- Max Release (uCi/cc) 1.62E-08 3.00E-07 5.39%
Water 0
0 CEDE, total (mrem) 2.81E-02 25 0.11%
"APPENDIX B LIMIT
%of LIMIT (uCi/cc) 3 E-07 5.39%
3 E-07 0.23%
3 E-07 0.00%
3 E-07 0.81%
2.11 E+08 (litres)
Total 0
0 CDE (Lung), total (mrem) 2.36E-01 25 0.94%
CEDE mrem 2.42E-02 8.56E-04 6.43E-06 3.04E-03 2.81E-02 CEDE (mrem) 1.18E-06 7.09E-08 3.53E-10 1.59E-07 1.41E-06 January 2018 -June 2018 Fiscal Weeks 1-26 CDE (Lung) mrem 2.03E-01 7.14E-03 5.36E-05 2.53E-02 2.36E-01 CDE (Bone CDE (Lung)
Surface)
(mrem)
(mrem) 7.44E-07 1.71E-05 4.50E-08 1.03E-06 2.25E-10 5.12E-09 1.01E-07 2.31E-06 8.90E-07 2.05E-05
- Limit from 10 CFR 20 Appendix B, Table 2, Columns 1 and 2. Air limit adjusted to reflect NRC License SNM-1 097, Section 1.3.9.
- From nuclide with release that is the largest percentage of its release limit.
NOTES:
Air sampling is continuous. Water samples analyzed are representative, continuous composite samples of the process effluent stream.