Whitepaper to Change Text of NEI 99-02 DEP Form Accuracy Page 1 of 3 20180822 - Alternative Proposal Introduction Licensees have developed initial notification forms to support notifying offsite response organizations (OROs) of a declared emergency and to communicate important event information (e.g., the applicable emergency action level and/or protective action recommendation). The information contained on a site-specific form is based on regulatory requirements and determined in consultation with the relevant OROs. While all the information on these forms is important to the emergency response, only the information related to the declared emergency action level (EAL) or development of a protection action decision (PAD) by an ORO should be tracked by the Drill/Exercise Performance (DEP) Performance Indicator (PI).
The criteria in NEI 99-02, Revision 7,1 for assessing the accuracy of an initial notification form consider all the listed form entries to have equal risk significance. This is based on the presumption that an error in any one of them will result in an unsuccessful performance indicator opportunity. Thus, currently, licensees are guided to report as DEP PI failures some incorrect form entries that would not materially impact ORO development of PADs.
NEI 99-02 Section Affected The guidance to be changed involves the criteria for assessing the accuracy of an initial notification form for alerting an ORO of an emergency declaration and/or Protective Action Recommendation (PAR). The affected text is found in NEI 99-02, Revision 7, markup attached.
Discussion The proposed resolution is to revise the guidance for assessing the accuracy of initial notification forms for the purposes of the DEP PI. The revised accuracy criteria identify form entries that are always required for ORO protective action decision-making (more risk significant) and eliminates those that are not critical to such decisions (less risk significant). Entries of the latter type need not be assessed for DEP PI purposes because they can be corrected on the spot during a notification or by a subsequent notification/communication with no impact on the effectiveness of ORO decisions. The proposed change is consistent with the initial notification form content guidance in Section II.E.3 of NUREG-0654/FEMA-REP-1, Revision 12 and Draft Revision 2.3 With respect to the other information contained on a site-specific form, this existing Clarifying Notes paragraph would apply:
It is understood that initial notification forms are negotiated with offsite authorities. If the approved form does not include these elements, they need not be added. Alternately, if the form includes elements in addition to these, those elements need not be assessed for accuracy when determining the DEP PI. It is, however, expected that errors in such additional elements would be critiqued and addressed through the corrective action system [emphasis added].
Related to the above discussion, the term Protective Action Recommendation, or PAR, should be added to the accuracy criteria because it subsumes two of the current initial notification form attributes, Whether offsite protective measures are necessary and Potentially affected population and areas.
1 Regulatory Assessment Performance Indicator Guideline, NEI 99-02, Revision 7, August 31, 2013. A line-in/line-out version, showing changes from Revision 6 to Revision 7, is available on the NRC web site at https://www.nrc.gov/docs/ML1326/ML13261A116.pdf.
2 Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants, NUREG-0654/FEMA-REP-1, Revision 1, November 1980. Available at https://www.nrc.gov/reading-rm/doc-collections/nuregs/staff/sr0654/r1/
3 NUREG-0654/FEMA-REP-1, Draft Revision 2 is available at https://www.nrc.gov/docs/ML1416/ML14163A605.pdf.
Whitepaper to Change Text of NEI 99-02 DEP Form Accuracy Page 2 of 3 20180822 - Alternative Proposal In other words, a PAR transmits the protective measures identified as necessary for a given population or area (e.g., evacuate a subarea or shelter a town). The DEP indicator Clarifying Notes section already uses the term PAR in a manner consistent with its addition to the form accuracy criteria.
Proposed Changes to NEI 99-02 (see markup)
As reflected in the attached markup, the initial notification form information to be assessed for accuracy is as follows:
Plant/site name Site-specific EAL identifier/number (e.g., RA 1.1 or HU1.2)
Time of declaration of emergency Whether a release is taking place due to the event Wind direction and speed, and stability class The protective action recommendation, if warranted Authorizing signature or other indication of authorization
Whitepaper to Change Text of NEI 99-02 DEP Form Accuracy Page 3 of 3 20180822 - Alternative Proposal Markup of Proposed Changes to NEI 99-02 Page 47 Line 38
- Initial notification form completed appropriate to the event to include (see clarifying notes):
39 - Class of emergency 40 - Site-specific EAL identifier/number (e.g., RA 1.1 or HU1.2)EAL number 41 - Description of emergency 42 - Wind direction and speed, and stability class 43 - The protective action recommendation, if warrantedWhether offsite protective measures are necessary Page 48 Line 1 - Potentially affected population and areas 2 - Whether a release is taking place due to the event 3 - Date and tTime of declaration of emergency 4 - Whether the event is a drill or actual event 5 - Plant/site namePlant and/or unit as applicable Authorizing signature or other indication of authorization Line numbers to be renumbered as needed in final version.