ML18228A671

From kanterella
Jump to navigation Jump to search
Harman Professional Solutions - NRC Form 591M, Part 1, Inspection Report 0339071/2018001
ML18228A671
Person / Time
Site: 03039071
(04-35446-01 E)
Issue date: 05/24/2018
From: Michelle Hammond
NRC Region 4
To:
Harman Professional Solutions
References
IR 2018001
Download: ML18228A671 (1)


See also: IR 07100201/1980001

Text

NRC FORM 591M PART 1

(4-2008)

U.S. NUCLEAR REGULATORY COMMISSION

10 CFR2.201

SAFETY INSPECTION REPORT AND COMPLIANCE INSPECTION

1. LICENSEE/LOCATION INSPECTED:

2. NRC/REGIONAL OFFICE

Harman Professional Solutions

8500 Balboa Blvd.

Northridge, California 91329

REPORT NO.: 2018-001

U.S. Nuclear Regulatory Commission

Region IV, 1600 East Lamar Blvd

Arlington, Texas 76011-4511

3. DOCKET NUMBER

030-39071

LICENSEE:

4. LICENSE NUMBER

04-35446-01 E

The inspection was an examination of the activities conducted under your license as they relate to radiation safety and to compliance with the Nuclear

Regulatory Commission (NRC) rules and regulations and the conditions of your license. The inspection consisted of selective examinations of

procedures and representative records, interviews with personnel, and observations by the inspector. The inspection findings are as follows:

cg]

D

D

D

1. Based on the inspection findings, no violations were identified.

2. Previous violation(s) closed.

3. The violations(s), specifically described to you by the inspector as non-cited violations, are not being cited because they were self-

identified, non-repetitive, and corrective action was or is being taken, and the remaining criteria in the NRC Enforcement Policy to exercise

discretion, were satisfied.

D Non-Cited Violation(s) was/were discussed involving the following requirement(s) and Corrective Action(s):

4. During this inspection certain of your activities, as described below and/or attached, were in violation of NRC requirements and are being

cited. This form is a NOTICE OF VIOLATION, which may be subject to posting in accordance with 10 CFR 19.11.

Licensee's Statement of Corrective Actions for Item 4, above.

I hereby state that, within 30 days, the actions described by me to the inspector will be taken to correct the violations identified. This statement of

corrective actions is made in accordance with the requirements of 10 CFR 2.201 (corrective steps already taken, corrective steps which will be taken,

date when full compliance will be achieved). I understand that no further written response to NRC will be required, unless specifically requested.

Title

Printed Name

Signature

Date

LICENSEE'S

REPRESENTATIVE

NRCINSPECTOR

BRANCH CHIEF

NRC FORM 591 M PART 1

Michelle M. Hammond

Michael Hay

D Non-Public D Sensitive -

Security-Related

0 Public

0 Non-Sensitive