41I4 I u i(.
(7 'JG)
'I' 4 N) I ~ V44 i4
~ i
<< 'Lfl. 4(% i VN I ( l 4 IIVI4VVIVIV t:ott f' b0 DOCKET M/tt I'I:.AI/ttL I:ICI!ftuMI)Cft Hr. Vicfor Stello, Jri I'IIOM:
Florida Power
& Light Company Hiami, Florida Robert E
Uhrig
~ I DATE OF OOCUMCWT 4/20/77 DATF-ftECEIVEO 4/25/77 III').cT I'I:n
+ontott4At Qcorv LIwoTo nlrb c D 8fut4ct.Asstrtr D Ffton s ~
II4I uT Fonts t4utvtl'alt Of'OPlf tt Itt'cC IVl 0 DESCftlf'1'lot4 Ltr. trans the following:
EIICt OSunE Consists.of additional information concerning Steam Generator. Xnspection Pro'gram.
~ ~
@C @or IIZMQ~
(2-,P)-
t Piht<T H/ttK Turkey Point Unit t<o.
4 RJL ACKNOW EDGEX)
SA I'ETY
/tSSXG ~HO An:
>>,IO,~Le), tt~,;:<C>:!<-
LXC~ !tSS'Z~;
&~act~, S Q/flCI N
~nasl.
~S "XCQ~~ h)).
~PJiUCIL~~):L-..
'PO 1'HCT YAK<GFR I,XC~ASSTt,~
F R ACl IOIt,/INI OR'4)Al ION
"'+/X)tO INTER)xALDIS1'Rl BU f)ON Nl
)'l)R X f~)', ~K or;I.o GOSSXC)i f: STAFF 1)7.PC Ch BL')/INAUE)l
)IARI.ESS PROJL'CT tfANAG!'.HFNT
)30YD I', COI,I.XtlS
)IOUSTOi'I I));"O'.RSOII Hl'.I.TZ H)'.I.'I.'I'.ter.."
8)iO")IOIT L)')))(;
'1')'C:
NSXC:
h S).13.
'1 Ip <:vs ups<<tm ttftC I DIIM tl)(i (2 'IG)
SYSTI'tfS SAP)'TY h),"Xi)I;:)"tN S) Cl)ROl))ER rtlGXNr)r)tX)IG
) IACARI'Y 1300?
lh)'i))!IF, <<.L PAHI.)'C,~J
)<)',ACTOR Sh)')."l+
ROSS t)OVA)'OS i'.TOC7 7 Cl)ECK ATFc X
Shl'f'/JAN
);IIi)3):.r'G EX I I, IINRI 13llll I)IUUTIOi~)
t'A'I', IA)I~
III?G V' ll'.
I.A,VI))t CQi ci)If.'1'Alx'I."i
'i!i i'
c.' +'
>>LAN<<T SYST)',)IH
'i'r)DE RCO
~)re')i/)POYA XP".OI.TTO
)HlQQf.GQD OPERATXNG IIHACTORS ST)'.LLO O>>::)V rX);G HAEC)f.
r)XsEN)IUT SIIAO
'81Jl'J,l:<<
filo)IF.8
)!I<OO!'))AVI'.H.I'.u.~
f+IT Qt'I)<< ' fg<<<<
I t!KQH & )i)I I
))AI.T.ARI)
SPANGLt'R sxT):
ir)c)1 Gh) 0 fiLL ST)'.PP lit)L)IAN SX'1'1'. A'NALYSXS VOI.I,)II,"R i)UNC)I J ~
COI.I.X)IS
): R I'.GI'.lt CON I I)
NUt'i)Ii):II
'77//
3 I I
)
g P. O. BOX 013100, MIAMI, FL 33101
+I+
+n- >>
FLORIDAPOWER & LIGHTCOMPANY April 20, 1977 L-77-117 ymgyo5 WUKll'lail'Pig Director of Nuclear Reactor Regulation Attn:
Victor Stello, Jr., Director Division of Operating Reactors U. S. Nuclear Regulatory Commission Washington, D. C.
20555
Dear Mr. Stello:
lpga~)
~~ e og
<4/(Pg 1
Re:
Turkey Point Unit 4
Docket No. 50-251 Su lementa'1 Information On April 11, 1977, Florida Power'a,Light Company submitted a Steam Generator Inspection Program for Turkey Point Unit 4 (L-77-112).
This letter forwards additional information concerning the inspection program.
Very truly yours, Robert E. Uhrig Vice President f
REU/GDW/hlc Enclosure cc:
Norman C. Moseley, Region II Robert Lowenstein, Esp.
~lrhd Sdi P EOP LE... S ERVIN G P EOP LE
I,
~
4 d
P P'll
/
aa
,r "k'4 Ih lb g
C
~ 8 A
1 f
i F
II
g t >ranÃ<<I ~M I SERlEc 44 818'l8785658119lll&57$ LBLlLSL%4$M5755535$ W4745454$ 393735333'I 292725232ll9$ 7}5.$3II 9 7 5 3 I
cot UMNS 90888L 78 7I 7g 7D 8 I L L4 S 'L54 52 44 M3 Z8 LZ2 l8 l6 }4
$2 86
~I
~
I
)
~
40 38 34 32 30 26 2Q 23 22 20 16 12 45~s 41 39 37 35 33 3$
Z9 27 25 23 21I)
I?
15 l3 s'
7 5
~ MA@V/AY wuzKEY PQIVI id< +
NOZZLE~
RQetS
TUBE PLUGGING CRITERIA FOR TURKEX POINT 4
Formation and implementation of plugging criteria for suspect.
steam generator tubing will be based on recognition of the probable causes that lead to possible tube degradation and the manner in which they occur.
Analysis and inspections resulted in the following basis which was implemented to establish a
plugging pattern and criteria in the recent Surry 2 shutdown.
1.
.The area of the plate which encompasses the high strain increases as the flow slots close.
2.
The strain in the plate is expected to be correlated to hoop 'strain in the tubes in the affected regions.
3.
Analysis indicates that plate strain may be correlated to tube leakage events (associated with a tube diameter reduction).
4.
Limited data for the Surry Units indicates that leaking
'in a dented region is most probable when tube'diameter is reduced below approximately
.500 inch..
C 5.
A rate of future strain increase can be estimated by
. ezigineering analysis of inspection results.
6.
Actual gauging. of the tube can be used to provide a cor-relation for the analysis results.
In the case, of Turkey Point 4, inspections and measurements of the flow slots will be done as a measure of the strain in the plates.
From these inspections and previous measurements, a
'plate strain rate can be determined.
This plate strain rate will be used in conjunction with gauging, of the tubes to determine the extent of severe strain and deformation of the tubes'..
Since the rate of growth of the severely strained area will then be estimated from inspection results and computer analysis and the boundaries of this area determined, the expected boundary of the strained korea, can be calculated for the next period of full power operation.
Tubes in the boundary growth area that are expected to become severe'ly strained and deformed during this period can be identified and plugged as a preventative measure.
Those tubes identified by gauging as severely deformed will also be plugged.
The steam generators in Turkey Point 4 have, to this date, experienced mild consequences of the tube diameter reduction as evidenced by the number and frequency of leaking tubes.
The plugging criteria developed and used for Surry 2 may therefore be overly restrictive for the actual conditions of the Turkey Point 4 steam generators.
Final criteria, for the anticipated period of operation, will be developed and implemented specifically for Turkey Point 4, as the results of th'e inspection program become evident.