U.S. NUCLI!AIIREGULATOR IMMI ION NIIC.lOAh1 195 I2 7G)

N II

- NBG-DISTRIBUTIONFoll PART ~0 DOCI(ET MATEfllAL DOC E

UMO(IA 50 250 251 FII E NU EE TO:

MR GGORGE LEAR,,'

~

a I IIONI: FQ)RXDA POWER Q LIGHT CO MIAMI~ FIA R E UHRIG DATE Ol'OCUMENT 5-20-76 DATE RECEIVED 5-2 -7 ljkLETTEA QORIGINAL UCOPV NOTOAIZED UNCLASSIFIED PROP INPUT FORM NUMOFA OF COPIES RECEIVED 3 SIGN 37 CC

= 40 W/ENCL DESCRIPTION LTR NOTORIZZD 5-.20-76....REF THEIR 4-8-76 SUBMITTAL....REQUEST TO AMEND CHANGE'O

= TECHSPEC..;.. TRANS THE FOLLOWING......

ENCLOSURE TABLE 4..1-2 SHEET 2 MINIMUMFREQUENCXLI'S FOR EQUIPMENT AND SAMPLING TESTS AND MEMO ON SAFETY..EVALUATION...;

..;....'ACKZOWLEDGZD

'LIOK&

ZEM~

PLANT NAME:

TURKEY POXNT 3 8'

SAFETY ASSIGNED AD:

FOR ACTION/I

% cocL NF0 RiblATION ASSXGNED hD ENVIRO I'kb BRANCH CHXEF:

PROJECT HANAGER; LIC~ASST'RANCH CHIEF ;

PROJECT tfhNAGER:

LIC~ ASST, FILE NRC PDR I &E QELD GOSSXCK & STAFF

~ASE QYjhlE LFM PROJECT HANAGEHENT BOYD P,

COLT.XNS HOUSTON PrTERSON HL'LTZ llELTEIIF.S S KOVIIOI.T T.PDI '

TXC NSg AS I.B

~CRG KIMXNG "I'NTERNAL D

S Sag Sg:

JW EN XNFJ~RN y CA KNXGHT S Ill"TEIL PAHLXCKX RrhCTOR SAFETY ROSS NOVAK ROSZTOCZY CHECK AT&X SALTZIIhN RUilIERG rlX'I'LllINALOISTRIOUTION NATI. IAB 1U'.G ~ V"

'Xl'.h TnR C()NSUI,ThNTS ISTR IBUTION BENAROYA

,AXNQ XPPOLITO OPERATING REACTORS STELLO.

OPERATXNG TECH F ISENIIUT Sl IAO BARR SCI 111ENCER GRXtl) S S'KTI'. St FETY & FNQTR ANhl.YSXS nl'.NTON & MUT.T.FR IIROOI:IlhVI'.N NATI. IXI)

UI.RIKS ON (Ol',NI.)

HEIR(LEE ERNST ALT.ARD SPANGLER SXTE TECH Ghl i+ilXLL STEPP SITE ANALYSIS VOI.LMER BUi'ICH J,

COLLXNS KREGER CONTIIOLNUMIIr.I<

53o~

r a

f t

~

o r I oo oo

~

~

~

~

o o h

o ~

o ~ ~

~

r 1

1 l'

rro r rI-.

r o

~

y r

I 11 h

o

~"

a ri eyq o

g iy)IIIjgi

<rr~ ~~~i~i<

FLORIDA POWER 5 LIGHT COMPANY L-76-198 May 20, 1976 Director of Nuclear Reactor Regulation Attn:

Mr. George Lear, Chief Operating Reactors Branch 43 Division of Operating Reactors U.

S. Nuclear Regulatory Commission Washington, D.

C.

20555

Dear Mr. Lear:

Re:"

Turkey Point Plant Units 3 and 4

Docket Nos.

50-250 and 50-251 Proposed Amendment to Facility Operating Licenses DPR-31 and DPR-41 i I I~i

~, +~ +CP g

Oy In accordance with 10 CFR 50.30, Florida Power a Light Company submits herewith three (3) signed originals and forty (40) copies of a request to amend Appendix A of Facility Operating Licenses DPR-31 and DPR-41.

This submittal modifies our proposed technical specifi-cation relating to the surveillance of spent fuel cask crane interlocks at Turkey Point Units 3 and 4, submitted on April 8, 1976.

The proposed change is as described below and as shown in the accompanying technical specification page bearing the date of this letter in the lower right, hand corner.

Table 4.1-2 Sheet 2

Interim controls to be used in lieu of those crane inter-locks not now installed have been added to Item 19.

I In earlier corresponded (reference our letter to Mr. Karl R. Goller, dated January 10, 1975), Florida Power 6 Light Company stated that interlocks would be installed to prevent operating the cask crane over spent fuel prior to moving any spent fuel with the cask.

Due to a longer than expected design period, these interlocks will not be available for the transfer of Unit 4 spent fuel to the Unit 3 spent fuel pit scheduled to commence June

7. It is felt that the proposed interim controls provide equal assurance that the cask crane hook will not be operated over spent fuel during the fuel transfer.

HELPING BUILD FLORIDA

II[o ~

Re:

Mr. George Lear Turkey Point Plant Units 3 and 4

Proposed Amendment to Facility 0 eratin Licenses DPR-31, DPR-41 May 29.,

1976 Page The crane interlocks will be installed and tested prior to the transfer of fuel from the Unit.,53 spent fuel pit to the Unit 4 spent fuel pit, scheduled to commence in June 1977.

The proposed amendment and safety evaluation are attached.

The proposed amendment has been reviewed and the conclusion reached that it does not involve a significant hazards con-sideration; therefore, prenoticing pursuant to 10 CFR 2.105 should not be required.

Very truly yours, Robert E. Uhrig Vice President REU/GDW/hlc Attachments cc:

Norman C. Moseley Jack R.

Newman, Esq.

J

~ t I

~

TABLE 4. 1-2 SHEET 2

MINIMUM FREQUENCIES FOR EQUIPMENT AND SAMPLING TESTS Check Fre uenc Maximum Time Between Tests 19.

Spent. Fuel*

Functioning Within 7 days 7 days when crane Cask Crane of using crane is being used to Interlocks to lift spent maneuver spent fuel cask fuel cask "Prior to June 1977, the following controls may be used in lieu of crane interlocks to prevent movement of the cask over spent. fuel:

1.

Indexing of the crane and trolley will be implemented.

2.

Once properly positioned, the respective crane bridge and trolley drives will be de-energized as appropriate.

3.

In addition, a mechanical bumper will be installed to limit trolley travel in the westward direction, such that movement of the spent fuel shipping cask over spent fuel is prevented.

5/20/76

SAFETY EVALUATION Spent fuel cask crane interlocks to prevent movement of the cask over spent fuel will not be installed prior to transferring spent fuel from the Unit 4 to the Unit 3 Spent Fuel Pit.

Substi-tute controls have been developed to provide assurance that the cask will not be moved over spent fuel.

These controls are summarized as follows:

1.

With the trolley still over the "alley"* the bridge will be positioned

.using tram marks such that the west end of the bridge is properly aligned over the fuel building opening.

2.

The bridge drive will be de-energized.

3.

The trolley would then be moved in the westerly direction until properly positioned above the cask loading area using its tram marks.

4.

The trolley drive would then be de-energized.

At this point the cask is properly positioned and only vertical movement of the crane hook is permitted.

5.

Once loaded, the cask would. be,~raised to clear the top of the spent fuel pool, the trolley drive re-energized, and the cask would be moved out of the fuel handling building.

With implementation of the above methods, the cask movements are positively controlled..

Therefore, it is concluded that these methods provide satisfactory assurance that the cask movements can be conducted in a safe manner during the period that the limit switches are not installed. It is also concluded that the level of assurance for safe operation provided by these controls, is equal to that provided by the limit switches.

The proposed amendment (1) does not involve a significant hazards consideration because there is no adverse change in the proba-bility or consequences of accidents or malfunctions of equipment important to safety and there is no reduction in the margin of safety as defined in the basis for any technical specification, and (2) provides reasonable assurance that the health and safety of the public will not. be endangered by operation in the proposed manner.

Activities associated with this amendment will be con-ducted in compliance with the Commission's regulations.

Issuance of this amendment will not be inimical to the common defense and security, or to the health and safety of the public.

  • Alley refers to the clear north-south passage. that is located just east of the Unit Nos.

3 and 4 auxiliary building,.=,.

STATE OF FLORXDA

)

)

ss.

COUNTY OF DADE

)

Robert, E. Uhrig, being first, duly sworn, deposes and says:

That he is a Vice President of Florida. Power a Light Company, the 'Licensee herein; That he has executed the foregoing document; that the state-ments made in this said document are true. and correct to the best of his 'knowledge, information and belief, and that he is authorized to execute the document on behalf of said Licensee.

Robert E. Uhrig Subscribed and sworn to before me this 8'ay of 1976 otary Public.c, z