.~. Entergx RBG-47890 August 13, 2018 Attn: Document Control Desk U.S. Nuclear Regulatory Commission 11555 Rockville Pike Rockville, MD 20852-2738 Entergy Operations, Inc.

River Bend Station 5485 U.S. Highway 61 N SI. Francisville. LA 70775 Tel 225-381-4374 William F. Maguire Site Vice President River Bend Station

SUBJECT:

Supplemental Information Related to License Renewal Application NRC Request for Additional Information Set 10 (4.2.1-1, 4.7.3-1 and 4.7.3-2)

River Bend Station, Unit 1 Docket No. 50-458 License No. NPF-47

References:

1) Entergy Letter: License Renewal Application (RBG-47735 dated May 25, 2017)
2) Entergy Letter: Response to License Renewal Application NRC Request for Additional Information (RAI) Set 10 (RBG-47835 dated March 26, 2018)

Dear Sir or Madam:

In Reference 1, Entergy Operations, Inc. (Entergy) submitted an application for renewal of the operating license for River Bend Station (RBS) for an additional 20 years beyond the current expiration date. In Reference 2, updated fluence values were provided for the license renewal application that were based on GEH calculation 003N2078 Revision 1. The purpose of this letter is to provide notification that an error has been identified in GEH calculation 003N2078 Revision 1. This error has been evaluated using the corrective action program and the values provided in Reference 2 remain applicable and the values in the license renewal application are not changing.

The error was the entering of 2.0861 rather than 2.8061 as the EFPY for combined operating cycles 10 and 11. This is an error of 0.72 EFPY. The calculation for fluence at the end of the period of extended operation included a 10% margin for future operating cycles. This 10%

factor for future operating cycles resulted in an effective margin of 2.866 EFPY in the total fluence projected through the end of the period of extended operation. Because the identified error is less than the available margin, the values provided in the license renewal application remain valid. Therefore, the fluence values in the license renewal application are not changing and no change is necessary for the evaluation of fluence effects on the reactor vessel and the reactor vessel internals.

No new commitments have been identified in this letter.

If you require additional information, please contact Mr. Tim Schenk at (225)-381-4177 or tschenk@entergy.com.

RBG-47890 Page 2 of 3 In accordance with 10 CFR 50.91 (b)(1), Entergy is notifying the State of Louisiana and the State of Texas by transmitting a copy of this letter to the designated State Official.

I declare under penalty of perjury that the foregoing is true and correct. Executed on August 13, 2018.

Sincerely,

~tLvJ....

WFM/RMC/dp

RBG-47890 Page 3 of 3 cc:

U. S. Nuclear Regulatory Commission Attn: Emmanuel Sayoc 11555 Rockville Pike Rockville, MD 20852 u.s. Nuclear Regulatory Commission Region IV 1600 E. Lamar Blvd.

Arlington, TX 76011-4511 u.s. Nuclear Regulatory Commission Attn: Ms. Lisa M. Regner, Project Manager 09-0-14 One White Flint North 11555 Rockville Pike Rockville, MD 20852 NRC Senior Resident Inspector Attn: Mr. Jeff Sowa 5485 U.S. Highway 61, Ste. NRC St. Francisville, LA 70775 Department of Environmental Quality Office of Environmental Compliance Radiological Emergency Planning and Response Section Ji Young Wiley P.O. Box 4312 Baton Rouge, LA 70821-4312 Public Utility Commission of Texas Attn: PUC Filing Clerk 1701 N. Congress Avenue P. O. Box 13326 Austin, TX 78711 -3326 RBF1 0157