ML18222A258

From kanterella
Jump to navigation Jump to search
Korea Hydro & Nuclear Power Co., Ltd - Submittal of Revised Technical Report on CCF Coping Analysis
ML18222A258
Person / Time
Site: 05200046
Issue date: 08/10/2018
From: Yeon Kim
Korea Hydro & Nuclear Power Co, Ltd
To: William Ward
Document Control Desk, Office of New Reactors
Shared Package
ML18225A338 List:
References
MKD/NW-18-0117L
Download: ML18222A258 (5)


Text

70-1312-gil, Yuseong-daero, Yuseong-gu, Daejeon, 34101, KOREA Tel: +82-42-870-5400 / Fax: +82-42-870-5449 http://www.khnp.co.kr August 10, 2018 Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Attention: Mr. William Ward Docket No.52-046 Division of New Reactor Licensing MKD/NW-18-0117L

Subject:

Submittal of Revised Technical Report on CCF Coping Analysis

References:

1. KHNP Letter MKD/NW-18-0040L, Submittal of Revised Technical Reports for the APR1400 Design Certification, dated March 27, 2018
2. KHNP Letter MKD/NW-18-0066L, Revised Response to RAI 45-7883 for the Question 07.09-2 (Rev.6), dated May 4, 2018 The purpose of this letter is to transmit one set of revised technical reports on CCF Coping Analysis for APR1400 Design Certification. Prior version had been submitted under Reference
1. This revision modifies Figure 4.1 to reflect the updated I&C System Architecture as indicated in the RAI response markup under Reference 2.

If additional information or clarification required, please contact Daegeun Ahn, Director of KHNP Washington DC Center, at ahn.daegeun@khnp.co.kr or 703-388-0592.

Sincerely, Yun-ho Kim Project Manager Advanced Reactors Development Laboratory Korea Hydro & Nuclear Power Co., Ltd.

Enclosures:

1. Affidavit KAW-18-0117
2. CCF Coping Analysis (Proprietary) (APR1400-Z-A-NR-14019-P, Rev.3)
3. CCF Coping Analysis (Non-Proprietary) (APR1400-Z-A-NR-14019-NP, Rev.3)

Enclosure 1 Affidavit KAW-18-0117 I, Jeong-kwan Suh, state the following:

1. I am the General Manager of Korea Hydro & Nuclear Power Co., Ltd. (KHNP), and as such I am authorized to request withholding the information transmitted with this letter from public disclosure and to execute this affidavit.
2. I am familiar with the criteria applied by KHNP to determine whether certain information is proprietary, and with the policies established by KHNP to ensure the proper application of these criteria.
3. The information, APR1400- Z-A-NR-14019-P, transmitted with this letter has been classified by KHNP as proprietary in accordance with the policies for the control and protection of proprietary and confidential information. The information regarded as proprietary is identified and marked consistent with the requirements of 10 CFR 2.390, § (b)(1)(i). Accordingly, the proprietary information is enclosed within brackets and the right-hand bracket carries a notation of TS to indicate that the trade secret nature of the information claimed to be proprietary is the basis for proposing that the information so identified be withheld from public disclosure.
4. Pursuant to the considerations set forth in 10 CFR Section 2.390(a), KHNP considers the information classified as proprietary to be trade secret information since it is design, analysis, or test information that would be difficult for a competitor to reproduce and hence provides an economic and competitive advantage to KHNP.
5. The need for designating the information as proprietary has been raised within KHNP.

The information is being treated proprietary and confidential and has not been disclosed by KHNP to the public.

6. Nondisclosure of the proprietary information transmitted with this letter is vital to the competitiveness held by KHNP and, hence, disclosure of the proprietary information transmitted in with this letter would have negative commercial impacts on the competitive position of KHNP in the U.S. nuclear market.
7. In accordance with KHNP policy, proprietary information contained in this document may be, or may have been, made available on a limited basis to regulatory bodies, customers, potential customers, and their agents, suppliers, and licensees, and others under suitable agreements providing for nondisclosure and limited use of the information.

I declare that the foregoing statements are true and correct to the best of my knowledge, information and belief.

Executed on August 8, 2018 Jeong-kwan Suh General Manager APR1400 Licensing Team Korea Hydro and Nuclear Power Co., Ltd

Enclosure 2 APR1400-Z-A-NR-14019-P, Rev.3 CCF Coping Analysis (Proprietary)