ML18219E021

From kanterella
Jump to navigation Jump to search
Confirming Verbal Report of 4/22/1976 Re Auxiliary Feed Water VMO-2ll Found to Be Installed with Flow in Wrong Direction
ML18219E021
Person / Time
Site: Cook  
(DPR-074, DPR-058)
Issue date: 04/23/1976
From: Jurgensen R
American Electric Power Company, Indiana Michigan Power Co, (Formerly Indiana & Michigan Power Co)
To: James Keppler
NRC/RGN-III
References
Download: ML18219E021 (4)


Text

N NRC FoBM 195 I2.7G I P

>> U.S. NUCLEAR BEGUI.ATOBYCot+/SION NRC DISTRIBUTION FoR pART 60 DOCKET MATERIAL p

DOCKE NUMBER FILE NUMBER INCIDEIQ'EPORT TO:

. Hr Keppler

'ROM:

Indiania 6 Mich>.gan Pwr Co Bridgman, Mich R

W Jurgensen DATE OF DOCUMENT 4-2S-7e DATE RECEIVED 4-28 7Q PALETTE R 0 ORIGINAL

%COPY ONOTORIZED kPUNCLASSIF IE D, PROP INPUT FORM NUMBER OF COPIES RECEIVED none..signed DL'SCRIPTION Ltr "reporting i'nformation concerning reported xuxia1.iary feed water valve FMO-211 fa2.lure'n 4 22 76

~

~

~

~

~

o

~

~

ENCLOSURE I IACKNQWLEDGED,

¹ NOT RElI/10/8 PLANT NAME:

Cook Ill NOTEt IF PERSONNEL EXPOSURE IS INVOLVED SEND DIRECTLY TO KREGER/J.

COLLINS SAPETY BRANCH CHIEF:

W 3 CYS FOR ACTION LXC~ ASST:

W/

CYS ACRS 6 CYS M%LDXVW NT TO LA FOR ACTION/INFORMATION ENVIRO D

e r P

NRC PDR I 6 E 2

INTERNALD ISTRI BUTION SCHROEDER/IPPOLXTO NOVAk~CHHCK

~R

~iHgJS~PEN H

Kh THDHSCO MACCA Y HQR.i BAER SIIAO VOLLMER BUNCH KILRG~E~COL ~ NS TXC NSXC EXTERNAL DISTRIBUTION CONTROL NUMBE R NBC I OBM ISS IP 7al

4

)059 iGgSX

~

~

~

srlcen v

/~ectria liJDIANA8 NICHIGANPOKIER CONPAIIIfY DONALD C. COOK NUCLEAR PLANT P.O. Box 458, Bridgman, Michigan 49106 April 23, 1976 Mr. J.G.

Keppler, Regional Director Office of Inspection and Enforcement United States Nuclear Regulatory Commission Region III 799 Roosevelt Road Glen Ellyn, IL 60137 Dear Mr. Keppler 1

Operating License DPR-58 Docket No. 50-315 This is to confirm our verbal report to NRC RO: III Inspector, Mr. K.R. Baker, of April 22, 1976.

At that time we reported that auxiliary feed water valve fMO-Zll was found to be installed with flow in the wrong direction.

A review of the consequences of this condition indicated that there were no adverse effects to the public health and safety.'ie are continuing our investigation and will submit a formal report by t'lay 6, 1976, as requi red by Nuclear Regulatory Commission Regulatory Guide 1.16, Revision 4, Section 2.a.

Since ly, R W. J ge n

Plant ana er Orr~~0 gg'ghat

/bab cc:

R.S.

Hunter JOE; Dolan G.E.

Lien R. Kilburn R.J.

Yollen BPI R.C. Callen MPSC K.R. Baker RO:III P.W. Steketee, Esq.

R. Walsh, Esq.

G. Charnoff, Esq.

G. Olson J.M.

Hennigan PNSRC R.S.

Keith Dir., IE (40 copies)

Dir., MIPC (4,copies)

E OQ 74 p'g)