PIRC FOPM 195 I2 76)x TO:
MR J G KEPPLER FROM: INDIANA 8o MICH3;GAN POWER CO BRIDGMANp MICH R W JURGENSEN
)5I ETTER 0 ORIGINAL
@COPY ONOTORIZED
+UNCLASSIFIED PROP INPUT FORM DESCRIPTION LTR 'FURN INVESTXGATXON RESULTS 'WHICH REVEALED THE STEAM GENERATOR BLOWDOWN RADIATION MONITOR WAS PLACE IN THE RESET POSITION IN VIOLATION OF TECH SPEC APPENDIX B. ~.'.
~.
~ ~
~
ENCLOSURE
.,j
\\
t v.S. NUCLEAR REGULATOR MMISSION
~w NRC DISTRIBUTION FDR PART 60 DOCKET MATERIAL DOCKET NUMBER Go-3,(G'ILE NUMBER DATE OF DOCUMENT 4-I4-q(
DATE RECEIVED 4-x<-14 NUMBER OF COPIES RECEIVED
<-Siss,eh PLANT NA~IE:C elk. 4 <
SAFETY ASSIGNED AD:
BRANCH CHIEF:
PROJECT IfANAGER:
LIC ASST,:
FOR ACTION/INFORMATION ASSX NED PRO NRC PDR I&E OELD GOSSICK & STAFF MIPC CASE HANAUER RLES INTERNALD SYSTEMS SAFETY HEXNEIfAN SCHROEDER ENGINEERING MACCARRY KNIGHT SIHWEIL PAWLICKI ISTR I BUTION
~ BENAROYA IPPOLITO K RKIPOOD OPERATIN REACTORS SITE ENVIRO ANAL S PROJECT MANAGEIIEN BOYD P
COLLINS HOUSTON PETERSON MELTZ HELTEMES SKOVHOLT LPDR:
TIC:
N
~
ASLB:
ACRS 6CYS HOLDIN NRC FORM f96 l2.'76l EN REACTOR SAFE'1IY ROSS NOVAK ROSZTOCZY CHECK AT& T.
SALTZMAN RUTBERG EXTERNALDISTRIBUTION NAT LAB:
REG ~
VXE LA PDR CONSULTANTS OPERAT N H
EISENH SHAO BAER BUTLER GRIMES BROOKHAVEN NA ULRXKSON ORNL CONTROL NUMBER
r rr
~ fg I'
C r
f'I C
h r
r f(g g
~
~ ~
~
=
~ ~
~
fute I'
A
I INDIANA&hII,CHIGANPDIVEII CDNIPANY L)ONALD C. COO'r NUCLEAR )eLA.i7 P.O.
BOX 458, Brtdg111:in, 5'tiChig;in 49106 June 16 1976
<10i Ilgwu
+
- POCKEEED, BMSQ 9 ~6@'P/P t'ir. J.
G. Yeppler, Regional Director 0ffice of Inspec tion and Enforcement United States t(uclear Regulatory Connissio Region I I I 799 Roosevelt Road Glen Ellyn, Illinois 60137 rEEIaEAR REGULATOR gOMMISSlog
/
I
Dear ter. Keppler:
Operating License DPR-58 Docket Ho. 50-315 AEO No. 50-315/76-03 While preparing for steam generator moisture carryover testing, it was determined that during previous testing of this nature on April 6, 7-and 8, 1976, the steam generator blowdown radiation monitor (R-19) was placed in the "reset" position.
This allowed blowdown to continue with excessive levels of tea" '.
This resulted in a violation of Technical Specifications, Appendix 8, Paragraph 2.4.2g which requires blowdown treatrznt if R-19 (steam generator blowdown radiation monitor) is not in service.
Investigation revealed that R-19 was put in the "reset" position so that blowdown would continue.
This>>as mistakenly done without recognizing the technical specification requiring the operation of R-19.
Sampling of the blowdown was conducted during and following the testing.
This sampling indicated the total t/a'ctivity released was
.308 curie, with the highest release rate being
.114e of the technical specification limit for topaz".
This release rate did not present a hazard to the health and safety of the public.
To prevent recurrence, test and staff personnel are now aware of the technical specification requiret-.. nt that blowdown treatment is required if R-19 is not in s. rvice.
W.
ge
. en Plant Ianager
/g I
cc:
Lis ted on fo 1 1 o ving page.
62VX
ter. J.
G. Keppler June 16, 1976 Page 2 of 2 CC:
R.
S. Hunter J.
E. uhlan G.
E. Lien R. Kilburn R. J. Vollen BPI R.
C. Callen t9SC K.
R.
Baker. RO:III P.
W. Steketee, Esq.
R. lv'alsh, Esq.
G. Cliarnoff, Esq.
G. Olson J.
H. Hennigan PttSRC R.
S. Keith J.
L. Rischling Dir., IE (20 copies)
Dir., tlIPC (2 copies)
Dir., Licensing (1 copy)