ML18219C155
| ML18219C155 | |
| Person / Time | |
|---|---|
| Site: | Cook |
| Issue date: | 02/13/1978 |
| From: | Dolan J American Electric Power Service Corp |
| To: | James Keppler NRC/RGN-III |
| References | |
| IEB-78-002 | |
| Download: ML18219C155 (4) | |
Text
AMF.RICAN ELECTRIC POPOVER Service Corporation 2 Broadway, Near York, K Y. )0004 (2)2) 422.4800 JOZN EDOLGf Scnior ErccvciecVicc PrcHdcnt Eagiarcn'eg February 13, 1978 Donald C.
Cook Nuclear Plant Units 1
& 2 Docket Nos.
50-315
& 50-316 DPR Nos.
58
& 74 Mr. J.
G. Keppler, Regional Director U.S. Nuclear Regulatory. Commission Office of Inspection and Enforcement Region III 799 Roosevelt Road Glen Ellyn, Illinois'0137
Dear Mr. Keppler:
This letter is in response to your letter of January 30, 1978, which transmitted IE Bulletin No. 78-02 to us.
The attached enclosure is submitted in fulfillment of the require-ment to respond to this IE Bulletin.
h Very truly yours, JED:em hn E. Dolan cc:
R.C. Callen G. Charnoff R.
W. Steketee R. Walsh R. J. Vollen R.
W. Jurgensen D. V. Shaller -Bridgman Director, Office of Nuclear Reactor Regulation Director of Reactor Operations Inspection FPg <] 1978
ATTACHMENT Donald C.
Cook Nuclear Plant Units 1 6
2 Docket Nos.
50-315 6 50-316 DPR Nos.
58 6
74
RESPONSE
TO IE JUL'LETIN NO.78-02 All terminal blocks on safety related circuits located inside the containments of D.C. Cook Units 1 and 2 are installed in pro-tective vented enclosures.
These enclosures are not subject to submergence, that is, they are above flood leve3
1