ML18214A202
| ML18214A202 | |
| Person / Time | |
|---|---|
| Site: | University of Missouri-Rolla |
| Issue date: | 08/01/2018 |
| From: | Alchin A, Reisner C Missouri Univ of Science & Technology |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| Download: ML18214A202 (18) | |
Text
OPERATOR REQUALIFICATION PROGRAM FOR THE MISSOURI UNIVERSITY OF SCIENCE AND TECHNOLOGY REACTOR Revision 4 l August 1, 2018
I OPERATOR REQUALIFICATION PROGRAM FOR THE MISSOURI UNIVERISTY OF SCIENCE AND TECHNOLOGY REACTOR License Number R-79 Docket Number 50-123 Prepared by:
Craig Reisner And Anthony Alchin Missouri University of Science and Technology Revision 4, January 10, 2018
II TABLE OF CONTENTS Table of Contents 1
Introduction............................................................................................................................. 1 2
Description of the Program...................................................................................................... 2 2.1 Requalification Cycle Examination and Retraining Lectures.......................................... 2 2.2 On-The-Job Training........................................................................................................ 4 2.3 Periodic Observation and Evaluation............................................................................... 4 3
Administration of the Program................................................................................................ 5 3.1 Training Coordinator........................................................................................................ 5 3.2 Reactor Manger................................................................................................................ 5 3.3 Licensed Operators........................................................................................................... 6 4
Records.................................................................................................................................... 6 Appendix........................................................................................................................................ 7
1 1 Introduction This document is the Operator Requalification Program for the Missouri University of Science and Technology Reactor(MSTR) which is required by 10 CFR 50.54(i)(i-1) and 10 CFR 55.59. All licensed operators at MSTR shall participate and satisfactorily complete this program during each licensed renewal period. Each licensed operator or senior operator shall include in his licensed renewal application a statement that he has satisfactorily completed the requirements of this Requalification program.
The generic term his will be used throughout this document in place of his/her, similarly he, him, ect
2 2 Description of the Program The Requalification program is divided into three major areas, which are designed to provide assurance that all operators maintain competence in all aspects of licensed activities. The three areas are as follows:
- a. A requalification cycle written examination, which is used to verify the operators knowledge level. Preplanned lectures shall be used to retrain those operators who demonstrate deficiencies in any part of the examination.
- b. On-the-job training, which will ensure (1) that the operator maintains his competence in manipulating the reactor controls and in operating all apparatus and mechanisms required by his license, (2) that the operator is cognizant of all design, procedure and license changes implemented during the requalification cycle, and (3) that he has a thorough understanding of all abnormal and emergency procedures.
- c. Periodic observation and evaluation which will evaluate the performance of the operators to actual and simulated reactor conditions.
- d. A requalification cycle consists of two consecutive calendar years with the first calendar as an odd year (e.g. 2005-2006).
2.1 Requalification Cycle Examination and Retraining Lectures During each requalification cycle, a comprehensive, written examination will be administered to all operators having a reactor operator or a senior reactor operator license for more than one year. The content of this examination should be similar to that of a license examination administered by the Commission. The function of the examination is to establish the knowledge level of the operator in all areas applicable to the licensed activities he performs. The results of this examination shall provide the basis for a determination of those areas in which each operator needs retraining.
The examination will be scheduled early enough to permit retraining before the end of the requalification cycle.
The examination will contain questions from each of the following areas:
A. Principles of Reactor Operation and Reactor Theory; B. Features of Facility Design; C. General and Specific Operating Characteristics; D. Plant Instrumentation and Control Systems E. Protective and Engineered Safety Systems; F. Standard and Emergency Operating Procedures; G. Radiation Control and Safety; H. Licensed, Technical Specifications and 10 CFR; I. Safety Analysis (only Senior Reactor Operators are required to have questions in this area, but can be asked to Reactor Operators also)
3 At the discretion of the facility Training Coordinator, a review program may be instituted to prepare individuals for the requalification cycle examination. The review program may utilize, but is not limited to the following study aids:
- a. Lectures or review seminars to present or discuss in a preplanned manner the information relative to each of the areas listed above. Personnel assigned to prepare questions or sections of the Requalification examination may be exempt for those specific questions or sections.
- b. Worksheet questions and problems, which the operator can answer in his spare time.
The Training Coordinator will be assigned responsibility to prepare the nine sections of the requalification cycle examination. The examination with answer sheet will then be reviewed by a faculty member from the Nuclear Engineering Department of the Missouri University of Science and Technology or an otherwise knowledgeable person.
The training Coordinator will assign to various staff members topics for which they must write, in outline form, and present to the rest of the staff in a formal lecture. The lectures will be on topics that will comply with 10 CFR 55, Appendix A. The evaluation of each operator will be facilitated by completing an examination record form as shown in Appendix A to this document.
An operator will be considered to be deficient in any area of the exam if he scores a grade of less that 70% in that area. If the average grade for an operator in all sections is less than 70%, the operator shall be relieved of all licensed activities until he has been retrained and satisfactorily passes re-examination with an average grade greater than 70%.
After all of the examinations have been graded, the Training Coordinator will prepare the retraining schedule for those operators who were deficient in any area. The Training Coordinator will use retraining schedule sheets as shown in Appendix A to facilitate the scheduling. The retraining program will consist of one or more preplanned lectures or tutoring sessions in each area of deficiency. These lectures will be supplemented by self-study or reference material.
After the retraining has been completed in each area, another examination will be given in that area to establish the operators competence. This re-examination will be of the scope and complexity of the original exam, but will contain a different set of questions.
All examinations and re-examinations after they have been graded will be reviewed with the operator and will be retained in the facilitys files for at least two years.
4 2.2 On-The-Job Training This section of the program provides assurance that all operators will maintain competence in those major evolutions, which can be performed by licensed operators only.
This section will also ensure that all operators maintain their knowledge of the facility to the extent that they are aware of all recent changes, which have been made to the license, to the facility and to the operating procedures. The on-the-job training requirements shall comply with 10 CFR 55.59 (c) (3) (i). Specifically, the items applicable to the Missouri University of Science and Technology Reactor include paragraphs (A), (B), and (E) of the above said regulation. The on-the-job requirements are outlined in detail in the checklist in Appendix of this document.
Each licensed operator shall acknowledge in writing a change in any operating procedure prior to conducting operations after the change has been implemented.
The on-the-job training requirements shall be spread out over the calendar year such that at least two of the total of five reactivity manipulations are completed in a six-month period. The Training Coordinator shall periodically review the on-the-job training checklist of each operator to ensure that he is progressing satisfactorily on his requalification.
2.3 Periodic Observation and Evaluation Reactor management will on a continuing basis observe and evaluate the performance of all operators in order to maintain familiarity with the operators competence in handling routine and emergency evolutions. This program implements the means of documenting the evaluations made by management.
The Training Coordinator, the Reactor Manager, or their designee (but a licensed operator) will annually conduct a performance evaluation of all operators during one of their reactivity manipulations. The person conducting the evaluation will complete an Operator Performance Evaluation Sheet (Appendix). The evaluator will also discuss or simulate abnormal or emergency conditions during the manipulations and grade the operator on his response to these conditions.
The response of an operator to a simulated or hypothetical emergency condition will be reviewed and evaluated by the Training Coordinator or Reactor Manger. This evaluation will be used to supplement that operators performance evaluations under this program.
Should an operator evaluation demonstrate an overall unsatisfactory performance, the operator will be relieved of licensed duties and be placed in an accelerated retraining program until satisfactory performance is demonstrated.
5 3 Administration of the Program 3.1 Training Coordinator The Facility Director shall assign a member of the reactor staff to be the Training Coordinator for this requalification program. The Training Coordinator shall be responsible for:
- a. Administrating the overall program.
- b. Scheduling the requalification cycle written examination.
- c. Preparing the written examination and conducting any necessary review and retraining.
- d. Assisting the instructors in the preparation of material, examinations, and retraining lectures or tutoring sessions.
- e. Reviewing the graded examinations with the operators and scheduling any retraining indicated by the examination results.
- f. Periodically reviewing the on-the-job training checklist of each operator to ensure that the operators are progressing satisfactorily in this area of requalification
- g. Scheduling the checks and review required by the Requalification Program.
- h. Scheduling the performance evaluations and the staff member who will conduct the evaluations.
- i. Maintaining all of the requalification records required by Section 4.0.
- j. Annually reviewing the content of this program.
- k. Ensuring that all newly licensed operators are aware of requirements of this program and are provided with the necessary requalification materials.
3.2 Reactor Manger The Reactor Manager will assist the Training Coordinator, as necessary; to ensure that all operators participate in and complete all of the requirements of this program prior to their license renewal date. They shall also schedule and conduct the reviews of changes in the license, facility design and operating procedures as required by the on-the-job training section.
6 3.3 Licensed Operators The extensive responsibilities of the Training Coordinator for administering this program do not relieve the individual licensed operator of the responsibility for ensuring that all of the requirements of this requalification program have been completed prior to their license renewal date.
4 Records As indicated in Section 3.1, the Training Coordinator is responsible for ensuring that all of the records required by this requalification program are maintained. The following records shall be retained at the facility during the time the operator license is valid:
- a. All examinations, and required re-examinations, which were administered during the requalification period and the answers used to grade these examinations.
- b. The examination review sheets completed after the requalification cycle examination and any subsequent re-examinations.
- c. The operator performance evaluation sheets used to evaluate the operators competence in operating the reactor.
- d. The retraining schedule used to correct any deficiencies discovered through the requalification cycle examination.
- e. Copies of the completed on-the-job training check sheets.
7 Appendix
ANNUAL ON-THE-JOB TRAINING REQUIRMENTS/CHECKLIST Name of Operator:
Year:_____ License: RO___ SRO___
8 I. Control Manipulations and Plant Evolutions In this paragraph the on-the-job training requirements outlined in 10 CFR 55.59 (c) (3)
(i), which are applicable to the MSTR are specified. For reactor operators and senior operators, these requirements consist of the following control manipulations and plant evolutions (senior operators may direct these activities): Five reactivity changes to be performed annually with at least one change in each of the categories:
- i. Startup ii. Power change iii. Shutdown II. Nuclear Instrumentation Checks Each licensed operator must perform at least two pre-startup checks of the Nuclear Instrumentation.
III. Reactor Fuel Handling Each reactor operator shall participate in one fuel handling evolution and each senior reactor operator shall direct the activities of one fuel handling evolution.
IV. Radiation Monitors (portable)
Each licensed operator shall annually demonstrate to the Training Coordinator (TC) or Reactor Manager (RM) that he knows how to use, read and interpret the reading of the portable radiation monitors most often used at the facility.
V. License Changes Each licensed operator shall annually review and demonstrate his knowledge of the license changes, which have become effective in the past year. This review is to be conducted by the Reactor Manager.
Meter Date TC or RMs Initials Neutron Monitor GM Counter Ionization Detector License Change Number Date Reviewed RM Initials
ANNUAL ON-THE-JOB TRAINING REQUIRMENTS/CHECKLIST Name of Operator:
Year:_____ License: RO___ SRO___
9 VI. Facility Design Changes Each operator shall annually demonstrate his knowledge of the facility design changes, which have occurred in the past month. This review is to be conducted by the Training Coordinator.
Modification No.
Date Reviewed TC Initials
ANNUAL ON-THE-JOB TRAINING REQUIRMENTS/CHECKLIST Name of Operator:
Year:_____ License: RO___ SRO___
10 OPERATIONS CHECKLIST Pre-Startup Checklist 1___ 2___
Startup ___
Power Change ___
Shutdown ___
Participate in Fuel Handling ___
Direct Fuel Handling (SRO only) ___
5 reactivity changes must be performed including 1 startup, power change, and shutdown.
Procedure Date Reactivity Change/Fuel Moved Pre-Startup Checklist
////////////////////////////////////
Pre-Startup Checklist
////////////////////////////////////
Reactivity Change Reactivity Change Reactivity Change Reactivity Change Reactivity Change Fuel Handling
ANNUAL ON-THE-JOB TRAINING REQUIRMENTS/CHECKLIST Name of Operator:
Year:_____ License: RO___ SRO___
11 MSTR OPERATOR REQUALIFICATION PROGRAM PERFORMANCE EVALUATION FORM Date ________________Evolution Performed_______________________
Excel. Good Aver. Poor Unsat.
PERFORMANCE UNDER NORMAL CONDITONS
- 1. Procedures - knowledge and understanding of
- 2. Console Log Entries - adequacy, completeness and legibility of entries
- 3.
Check sheets and Data Sheets - thoroughness in completing checklist, accuracy of and interpretation of data on data sheets
- 4.
Manipulation of Controls - proficiency in handling controls and positive approach to handling the plant
- 5. Use of Instrumentation - used all available instrumentation and properly interpreted same
- 6.
Awareness of Reactor Conditions -
knowledge of plant conditions, understanding trends or abnormal indication, response to changing conditions ABNORMAL OR EMERGENCY CONDITIONS
- 7.
Immediate actions - recognized condition and took immediate steps to put plant in safe condition
- 8.
Communications - communicated problem, took charge, initiated or directed corrective action
- 9. Follow-up Actions - ability to recover plant OVERALL PERFORMANCE
ANNUAL ON-THE-JOB TRAINING REQUIRMENTS/CHECKLIST Name of Operator:
Year:_____ License: RO___ SRO___
12 Abnormal or Emergency Conditions Imposed or Observed Comments and Recommendations Evaluator_________________________________
Managers Signature________________________
ANNUAL ON-THE-JOB TRAINING REQUIRMENTS/CHECKLIST Name of Operator:
Year:_____ License: RO___ SRO___
13 MSTR OPERATOR REQUALIFICATION CYCLE EXAMINATION FORM EXAMINATION TOPIC Comp Grade Exam Date Reexamination Grade Reexamination Date A. Principles of Reactor Theory.
B. Features of Facility Design.
C. General and Specific Operating Characteristics.
D. Instrumentation and Control Systems.
E. Protective and Engineered Safety Systems.
F. Standard and Emergency Operating Procedures.
G. Radiation Control and Safety.
H. Licensed, Technical Specifications and 10 CFR.
- I. Safety Analysis Average Score
- Not required of ROs REQUALIFICATIN
SUMMARY
Retraining Required No ____ Yes ____ Parts (circle) A B C D E F G H I Recommend relieved of normal licensed activities while retraining No ____ Yes ____
Comments
ANNUAL ON-THE-JOB TRAINING REQUIRMENTS/CHECKLIST Name of Operator:
Year:_____ License: RO___ SRO___
14 Quarter 1 Startup Checklist*
Startup*
Power Change*
Shutdown*
Shutdown Checklist January February March Quarter 2 Startup Checklist*
Startup*
Power Change*
Shutdown*
Shutdown Checklist April May June Quarter 3 Startup Checklist*
Startup*
Power Change*
Shutdown*
Shutdown Checklist July August September Quarter 4 Startup Checklist*
Startup*
Power Change*
Shutdown*
Shutdown Checklist October November December Requirements per year: *2 per year
ANNUAL ON-THE-JOB TRAINING REQUIRMENTS/CHECKLIST Name of Operator:
Year:_____ License: RO___ SRO___
15 Quarter 1 Licensed Duty*
Date Performed Start Time End Time Total Time Spent January February March Quarter 2 Licensed Duty*
Date Performed Start Time End Time Total Time Spent April May June Quarter 3 Licensed Duty*
Date Performed Start Time End Time Total Time Spent July August September Quarter 4 Licensed Duty*
Date Performed Start Time End Time Total Time Spent October November December Licensed Duties - Reactor Operations, Supervising Operations, SRO on Duty, etc.