NRC FORM 591 M PART 1 U.S. NUCLEAR REGULA TORY COMMISSION (07-2012) 10 CFR 2.201 SAFETY INSPECTION REPORT AND COMPLIANCE INSPECTION
- 1. LICENSEE/LOCATION INSPECTED:
U.S. Silica Company 200 North LaSalle Street, Suite 2100 Chicago, IL 60601 Location Inspected:
Berkley Springs, WV REPORT NUMBER(S) 2018-002 2. NRG/REGIONAL OFFICE Region III U. S. Nuclear Regulatory Commission 2443 Warrenville Road, Suite 210 Lisle, IL 60532-4352
- 3. DOCKET NUMBER(S}
- 4. LICENSE NUMBER(S)
- 5. DATE(S) OF INSPECTION 030-38792 12-35194-01 June 27, 2018 LICENSEE:
The inspection was an examination of the activities conducted under your license as they relate to radiation safety and to compliance with the Nuclear Regulatory Commission (NRC) rules and regulations and the conditions of your license. The inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations by the inspector.
The inspection findings are as follows: [ZJ 1. D 2. D 3. D 4. Based on the inspection findings, no violations were identified.
Previous violation(s) closed. The violations(s), specifically described to you by the inspector as non-cited violations, are not being cited because they were self-identified, non-repetitive, and corrective action was or is being taken, and the remaining criteria in the NRC Enforcement Policy, to exercise discretion, were satisfied.
Non-cited violation(s) were discussed involving the following requirement(s):
During this inspection, certain of your activities, as described below and/or attached, were in violation of NRC requirements and are being cited in accordance with NRC Enforcement Policy. This form is a NOTICE OF VIOLATION, which may be subject to posting in accordance with 10 CFR 19.11. (Violations and Corrective Actions) Statement of Corrective Actions I hereby state that, within 30 days, the actions described by me to the Inspector will be taken to correct the violations identified.
This statement of corrective actions is made in accordance with the requirements of 10 CFR 2.201 (corrective steps already taken, corrective steps which will be taken, date when full compliance will be achieved).
I understand that no further written response to NRC will be required, unless specifically requested.
TITLE PRINTED NAME SIGNATURE DATE LICENSEE'S REPRESENTATIVE NRC INSPECTOR Randy Ragland, Region I BRANCH CHIEF Aaron Mccraw NRC FORM 591M PART 1 (07-2012)
Y+ G~ (for RR) 07/24/2018 V
NRC FORM 591M PART 3 U.S. NUCLEAR REGULATORY COMMISSION (07-2012) 10 CFR 2.201 Docket File Information SAFETY INSPECTION REPORT AND COMPLIANCE INSPECTION
- 1. LICENSEE/LOCATION INSPECTED:
U.S. Silica Company 200 North LaSalle Street, Suite 2100 Chicago, IL 60601 Location Inspected:
Berkley Springs, WV REPORT NUMBER(S) 2018-002 3. DOCKET NUMBER(S) 030-38792
- 6. INSPECTION PROCEDURES USED 87124 2. NRG/REGIONAL OFFICE 4. LICENSE NUMBER(S) 12-35194-01 Region III U.S. Nuclear Regulatory Commission 244 3 Warrenville Road, Suite 210 Lisle, IL 60532-4352
- 5. DATE(S) OF INSPECTION June 27, 2018 7. INSPECTION FOCUS AREAS 03.01 -03.07 SUPPLEMENTAL INSPECTION INFORMATION
- 1. PROGRAM CODE(S) 03120 2. PRIORITY 5 3. LICENSEE CONTACT 4. TELEPHONE NUMBER Kayla Bucheimer
-Site RSO 1] Main Office Inspection Next Inspection Date: [ZI Field Office Inspection 2496 Hancock Road, Berkley Springs, WV CJ Temporary Job Site Inspection No Change -*-------*--*--*-------~--
PROGRAM SCOPE (304) 433-6337 This was an unannounced assist inspection of a silica manufacturer authorized to use byproduct material in fixed gauges to provide density measurements for controlling industrial processes.
At the time of the inspection, the licensee possessed four gauges at its plant in Berkley Springs, West Virginia:
two TN Technologies Model 5202 gauges and two Texas Nuclear 5080 Series gauges. One 5202 gauge was in storage awaiting disposal; the other was in use. The two 5080 gauges were mounted to process equipment but were not currently in use. Note that the licensee's RSO is based near the Berkley Springs plant, but receives correspondence at the mailing address listed on the license. PERFORMANCE OBSERVATIONS The inspector toured the facility in Berkeley and conducted radiological surveys of all the gauges using an Eberline R0-2 meter (NRC Serial No. 1239, calibration date 12/08/2017).
All exposure rates were within the ranges listed on the applicable sealed source and device registries.
All general area dose rates near the installed gauges were less than 0.1 mR/h. The inspector reviewed current records for leak tests, inventory, shutter tests, and self-assessments, and interviewed the site RSO, who was knowledgeable of license and program requirements.
No violations ofNRC requirements were identified as a result of this inspection.
NRC FORM 591M PART 3 (07-2012)