Purdue University - NRC Form 591M Parts 1 & 3, Inspection Report 07000152/2018001 (DNMS)
ML18204A115
Person / Time
Site: 07000152
Issue date: 07/16/2018
From: Folch L
NRC/RGN-III
To: Schweitzer J
Purdue University Research Reactor, Indiana
References
IR 2018001
Download: ML18204A115 (3)


Text

NRC FORM 591M PART 1 U.S. NUCLEAR REGULATORY COMMISSION (07-2012) 10CFR 2.201 SAFETY INSPECTION REPORT AND COMPLIANCE INSPECTION

1. LICENSEE/LOCATION INSPECTED:

Purdue University West Lafayette, Indiana 47907 REPORT NUMBER(S) 201800 I

3. DOCKET NUMBER(S) 070-00152 LICENSEE:
2. NRG/REGIONAL OFFICE
4. LICENSE NUMBER(S)

SNM-142 Region III U. S. Nuclear Regulatory Commission 2443 Warrenville Road, Suite 210 Lisle, IL 60532-4352

5. DATE(S) OF INSPECTION July 16, 2016 The inspection was an examination of the activities conducted under your license as they relate to radiation safety and to compliance with the Nuclear Regulatory Commission (NRC) rules and regulations and the conditions of your license. The inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations by the inspector. The inspection findings are as follows:

0 1.

D 2.

D 3.

D 4.

Based on the inspection findings, no violations were identified.

Previous violation(s) closed.

The violations{s), specifically described to you by the inspector as non-cited violations, are not being cited because they were self-identified, non-repetitive, and corrective action was or is being taken, and the remaining criteria in the NRC Enforcement Policy, to exercise discretion, were satisfied.

Non-cited violation(s) were discussed involving the following requirement(s):


~

During this inspection, certain of your activities, as described below and/or attached, were in violation of NRC requirements and are being cited in accordance with NRC Enforcement Policy. This form is a NOTICE OF VIOLATION, which may be subject to posting in accordance with 10 CFR 19.11.

(Violations and Corrective Actions)

Statement of Corrective Actions I hereby state that, within 30 days, the actions described by me to the Inspector will be taken to correct the violations identified. This statement of corrective actions is made in accordance with the requirements of 10 CFR 2.201 (corrective steps already taken, corrective steps which will be taken, date when full compliance will be achieved). I understand that no further written response to NRC will be required, unless specifically requested.

TITLE PRINTED NAME SIGNATURE DA TE LICENSEE'S REPRESENTATIVE NRC INSPECTOR Luis Nieves Folch BRANCH CHIEF Aaron T. McCraw NRC FORM 591M PART 1 (07-2012)

/-

I,

NRC FORM 591M PART 3 (07-2012) 10 CFR2.201 U.S. NUCLEAR REGULATORY COMMISSION Docket File Information SAFETY INSPECTION REPORT AND COMPLIANCE INSPECTION

1. LICENSEE/LOCATION INSPECTED:

Purdue University West Lafayette, Indiana 47907 REPORT NUMBER(S) 2018001

3. DOCKET NUMBER(S) 070-00152
6. INSPECTION PROCEDURES USED 87126
2. NRG/REGIONAL OFFICE
4. LICENSE NUMBER(S)

SNM-142 Region III U. S. Nuclear Regulatory Commission 2443 Warrenville Road, Suite 210 Lisle, IL 60532-4352

5. DATE(S) OF INSPECTION July 16, 2016
7. INSPECTION FOCUS AREAS 03.01-03.08 SUPPLEMENTAL INSPECTION INFORMATION
1. PROGRAM CODE(S) 21310
2. PRIORITY 5

[Z] Main Office Inspection D Field Office Inspection D Temporary Job Site Inspection

3. LICENSEE CONTACT
4. TELEPHONE NUMBER Jim Schweitzer, Ph.D., RSO (765) 494-2350 Next Inspection Date:

July 16, 2023 PROGRAM SCOPE This was an unannounced, routine inspection of Purdue University's SNM license. The licensee possessed material under this license for research and student instruction. The licensee's authorization included various percent enriched uranium fuel rods; pellets, sources, and samples; natural uranium; a PuBe subcritical assembly; and various sources used in a Fast Breeder Blanket Facility (FBBF). The FBBF had been in secured storage since the previous inspection.

The Radiological and Environmental Management (REM) office conducted source inventories and area surveys in accordance with the terms of the license. Access to all materials was restricted to authorized members of the REM and users within the Physics and Nuclear Engineering departments. In May 2018, the licensee transferred all the sources under this license to DOE. The inspectors reviewed the survey and transfer records.

The inspection included a review of the licensee's reporting to NMMSS in accordance with the procedures described in EGM 08-002. This inspection consisted of tours of the FBBF and material storage rooms, a review of select records, interviews with licensee staff, and independent surveys.

No violations ofNRC requirements were identified during this inspection.

NRG FORM 591 M PART 3 (07-2012)

Nieves Folch, Luis From:

Sent:

To:

Subject:

Attachments:

Dear Mr. Moore,

Nieves Folch, Luis Friday, July 20, 2018 1:09 PM

'mmtang@purdue.edu' NRC clear 591 report SKM_C45818072014050.pdf Attach is the clear 591 report for the inspection conducted on July 16, 2018, no further actions are required at this moment on your part.

In accordance with Title 10 of the Code of Federal Regulations 2.390 of the NRC's "Rules of Practice," a copy of this message will be available electronically for public inspection in the NRC's Public Document Room or from the NRC's Agencywide Documents Access and Management System (ADAMS), accessible from the NRC's website at http://www.nrc.gov/reading-rm/adams.html.

Please feel free to contact me if you have any questions regarding this correspondence.

Thank you, Luis Nieves Health Physicist U.S. Nuclear Regulatory Commission Division of Nuclear Materials Safety Office: (630) 829-9571 Fax: (630) 515-1259 1