Text
Footnote 1 - The Design Certification Application was submitted via a transmittal letter dated December 31, 2016 March 4, 2019 Mr. Thomas Bergman Vice President, Regulatory Affairs NuScale Power, LLC.
1100 NE Circle Boulevard, Suite 200 Corvallis, OR 97330
SUBJECT:
NUSCALE POWER, LLC, DESIGN CERTIFICATION APPLICATION - SAFETY EVALUATION WITH OPEN ITEMS FOR CHAPTER 9, AUXILIARY SYSTEMS
Dear Mr. Bergman:
The U.S. Nuclear Regulatory Commission (NRC) staff is preparing a safety evaluation (SE) with open items (OIs) for each chapter of the NuScale Power, LLC (NuScale) Design Certification Application submitted by NuScale on January 6, 20171.
The NRC staffs SE with OIs for Chapter 9, Auxiliary Systems, is being provided to the Advisory Committee on Reactor Safeguards (ACRS) to support an upcoming meeting of the ACRS Subcommittee, scheduled to be held on March 20, 2019.
The enclosed SE with OIs is being provided to NuScale for review of proprietary information pursuant to Title 10 of the Code of Federal Regulations (10 CFR), Section 2.390, Public Inspections, Exemptions, Requests for Withholding. The NRC will withhold the enclosed SE from public disclosure for ten business days from the date of this letter to allow you the opportunity to identify any proprietary information or factual errors. If within that ten day period, you do not request that all or portions of the SE be withheld from public disclosure, the enclosure will be made available for public viewing through the Publicly Available Records component of NRCs Agencywide Documents Access and Management System and placed on the NRCs public webpage for this application.
Document transmitted herewith contains sensitive unclassified information. When separated from the enclosure, this document is DECONTROLLED.
If you have any questions or comments concerning this matter, I can be reached at (301) 415-8013 or via e-mail address at Getachew.Tesfaye@nrc.gov.
Sincerely,
/RA/
Getachew Tesfaye, Senior Project Manager Licensing Branch 1 Division of Licensing, Siting, and Environmental Analysis Office of New Reactors Docket No.52-048
Enclosure:
As stated cc: w/o encl.: DC NuScale Power, LLC Listserv
PKG: ML18201A381 Letter: ML18201A383 SE: ML19055A001