1 Holtec-CISFEISCEm Resource From:
Virginia Mudd <gibimudd@plateautel.net>
Sent:
Thursday, July 12, 2018 1:03 PM To:
Holtec-CISFEIS Resource
Subject:
[External_Sender] Docket ID NRC-2018-0052; Holtec Internationals HI-STORE CIS Facility for Spent Nuclear Fuel, Lea County, New Mexico I respectfully reject the Holtec Environmental Report (ER) proposal to bring up to 100,000 metric tons of spent fuel, high-level radioactive waste from nuclear reactors around the country to southeast New Mexico. I do not consent to New Mexico becoming a national radioactive waste dumping ground. I do not consent to transporting up to 10,000 canisters of highly radioactive waste through thousands of communities nationwide. I do not consent to the risk of contamination of our lands, aquifers, air, or the health of plants, wildlife and livestock. I do not consent to endangering present and future generations to line the pockets of Holtec International.
I request that at least one scoping meeting be held in Dallas/Ft. Worth, San Antonio and Midland, Texas since there would likely be extensive transport through these cities, and that meetings be held in other major cities along transport routes throughout the country.
Here are a few concrete things I urge you to consider:
- 1. This Holtec Proposal Is Contrary to Current Law Current law only allows the U.S. Department of Energy to take title to commercial spent fuel following commencement of operation of a repository or at a DOE-owned and operated monitored retrievable storage facility. The Holtec site meets neither requirement, as it is a private facility.
- 2. Holtec Must Remove Copyrights and All Redactions in the Environmental Report NRC must require Holtec to produce an ER that has no such copyright restriction and has no redactions.
- 3. The Impacts of Permanent Storage Must Be Analyzed The Environmental Report (ER) is inadequate and incomplete because it does not analyze the impacts of the spent fuel being left at the Holtec site indefinitely.
- 4. More Alternatives Must Be Analyzed Keeping the spent fuel casks in some form of Hardened On Site Storage (HOSS) on the reactor sites must be analyzed.
The alternative of consolidated storage being done at an existing licensed Independent Spent Fuel Storage Facility (ISFSI) must also be analyzed.
- 5. The Environmental Report inadequately discusses the Transportation Risks This ER must include all transportation routes and the potential impacts of accidents or terrorism incidents on public health and safety along all the routes.
The ER is inadequate and incomplete because it does not discuss how rail shipments from reactors without rail access would be accomplished and the risks and impacts of such shipments.
- 6. The Consequences to an Accident-Exposed Individual Must Be Analyzed Terms like collective dose risk and person-rem are used to ignore the potential impacts to a single individual.
- 7. Cracked and Leaking Casks Must Be Addressed The ER does not analyze exactly how radioactive waste from a cracked and leaking canister would be handled, since there is no wet pool or hot cell at the site.
2
- 8. More Cumulative Impacts Must Be Analyzed The ER mentions WIPP but does not analyze the impacts of a radiologic release from WIPP on the proposed CIS site.
- 9. Impacts of Future Railroads and Electric Lines Must Be Analyzed The railroads and electric lines are not in place, but must be analyzed.
- 10. How many of the estimated 135 jobs will go to locals?
The total number of annual workers at the site could total as many as 135 when construction jobs are combined with the operating workforce.
- 11. Seismic Impacts on Stored Casks Must Be Stated Although the ER gives a statement on recent seismic activity in the area, there is no analysis of what impacts many 3.0 - 4.0 fracking-induced earthquakes will have on the buried casks.
- 12. The impacts of global warming on climate in the region and the resulting impacts on casks and canisters, in relation to their ratings, must be considered.
Thank you for your consideration, Virginia Mudd 87565
Federal Register Notice:
83FR13802 Comment Number:
174 Mail Envelope Properties (732440098.20511.1531414985863.JavaMail.tomcat)
Subject:
[External_Sender] Docket ID NRC-2018-0052; Holtec Internationals HI-STORE CIS Facility for Spent Nuclear Fuel, Lea County, New Mexico Sent Date:
7/12/2018 1:03:05 PM Received Date:
7/12/2018 1:03:08 PM From:
Virginia Mudd Created By:
gibimudd@plateautel.net Recipients:
Post Office:
vweb204 Files Size Date & Time MESSAGE 3861 7/12/2018 1:03:08 PM Options Priority:
Standard Return Notification:
No Reply Requested:
No Sensitivity:
Normal Expiration Date:
Recipients Received: