NRC FORM 195

{2 7G)

.U.S. NUCLI'AR REGULATORV COMMISSION 50- 39'7 DOCKET NUMBER NRC DISTRIBUTION FoR PART 50 DOCKET MATERIAL FILE NUMBER TO:

DL FROM:

Washington Public Pwr Supply

Richland, Wash D L Renber er DATE OF DOCUMENT 2-6-76 DATE RECEIVED 2910-76

+LETTER lORIGINAL Qcopv CINOTO R IZ E D I/UNCLASSIFIED PROP INPUT FORM NUMBER OF COPIES RECEIVED one signed DESCRIPTION Ltr re their 11-10-75 ltr.........advising that info concerning Mark II containment will be delayed until 3-15-76......

ENCLOSURE WPPS 8'2 SAFETY FOR ACTION/INFORMATION ENVIRO 76 ehf ASSXGNED AD:

BRANCH CHXEF

~

PROJECT MANAGER; ovn

/-

n c.

L Sh &~ ISO ASSIGNED AD :

BRANCH CHXEF

~

PROJECT MANAGER:

LXC, ASST' RC PDR I &E OI~

GOSSXCK & STAFF PROJECT MANAGEMENT BOYD P,

COLLINS HOUSTON PETERSON MELTZ HELTEIIES SKOVHOLT LPDR ~

)c.

n,~

TIC NS ASLB NRC FORM 106 {2.76)

INTERNALD GX$3M$

E

.%W 1SI KNXGHT SIHWEIL PAWLXCKI REACTOR SAFETY ROSS NOVAK 3

ROSZTOCZY CHECK SALTZMAN RUTBERG EXTERNAL DISTRIBUTION NATL LAB REG, V"IE LA PDR CONSULTANTS L~

Res ISTRI BUTION BENAROYA XPPOLITO OPERATING REACTORS STELLO OPERATING TECH EXSENHUT SHAO BAER SCIIWENCER GRIMES SITE SAFETY & ENV R ANALYSIS DENTON & MULLER BROOKHAVEN NATL LAB ULRIKSON(ORNL)

ERNST ALLA D SPANGLER SITE TECH GAMMILL STEPP HULIIAN SITE ANALYSIS VOLI2IER BUNCH J.

COLLINS KREGER CONTROL NUMBER l 3 III

~

~

~

~

~

~

~

~

It

~

~

~

~

~

gton Public Power Supply System A JOINT OPERATING AGENCY Docket No. 50-397 Director of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Hashington, D.C.

20555 Februarv 6,

1976 G02-76-40

, )6.th

.t-gyo>97$ ~

S ~ HBCL1AE E1~

U.

~

60IAIAIyEH 1Asd1 9sdIOS JP Attention:

Dr. Halter R. Butler, Chief Light Hater Reactors Project Branch 1-2

Subject:

HPPSS NUCLEAR PROJECT NO.

2 MARK II CONTAINMENT - DESIGN EVALUATION REPORT

Reference:

1)

Letter, H.R. Butler to J. J. Stein, Suppression Pool Hydrodynamic Loads During LOCA, April 17, 1975.

2)

Letter, H.R. Butler to J.J.

Stein,

(

Pool Dynamic Loads Due to Relief Valve Operation, April 23, 1975.

3)

Letter, N.O. Strand to O.D. Parr, Mark II Containment
Program, November 10, 1975 (G02-75-310)

Dear Dr. Butler:

This letter is to inform you of a delay in the schedule for the completion of the plant-unique design evaluation report previously given to you in Reference 3.

Because of the extensive analytical effort required to com-plete the structural evaluation and to determine the design

adequacy, we project the assessment cannot be completed and submitted to you until March 15, 1976.

This design evaluation report, which we will submit to you on March 15, will include our conclusion regarding the adequacy of design for the HPPSS Nuclear Project No.

2 containment.

~\\

E V

II 1 ll e

N A'

3r. lJalter R. Butler Page 2

February 6, 1976 802-76-40 If you have any questions on this matter, please do not hesitate to contact us.

Very truly yours, DLR:GLG:cab D. L.

RENBERGER Asst. Director Generation and Technology cc:

FA NacLean -

GE JJ Byrnes -

BSR JJ Verderber - B8R D

Roe -

BPA

~,

I Ii~

.K.~

r

~1 J'