GE Report, Analytical Model for Estimating Drag Forces on Rigid Submerged Structures Caused by LOCA and Safety Relief Valve Ramshead Air Discharges, NEDO-21471, Dated Sept. 1977
ML18191A185
Person / Time
Site: Columbia 
Issue date: 01/27/1978
From: Sobon L
General Electric Co
To: Stolz J
Office of Nuclear Reactor Regulation
References
MFN-040-78, NEDO-21471
Download: ML18191A185 (4)


Text

STANDARD DISTRIBUTION F C MIN I

TERIAL RELATING TO II CONTAINMENT NRC FORM 196 I2-78)

UA. NUCLEAR REQULATORV CO ISSIO 0 7OPrc R' NRC DISTRI8UTION FoR PART 60 DOCKET MATERIAL

%&i%MNM%

TOP ICAL REPORT Mr. John F. Stolz FROM:

General Electric San Jose, Ca.

95125 L. J.

Sobon OATE OF'OOCUMENT 01/27/78 OATE RECEIVEO 02/01/78 QLETTER QORIQINAL Qcopv QNOTORIZEO QUNCLASSIFIED PROP INPUT FORM NUMSER OF COPIES RECEIVEO OESCRIPTION G

E~ Rept entitled-

"AnalyticalModel For Estimating Drag Forces On Rigid Submerged Structures Caused By LOCA And Safety R'elief Valve Ramshead Air Discharge NED0-21471, dtd September, 1977....

jcm 02/02/78 1p LETTERS OF INCORPORATION WILL BE PLACED IN EACH DOCKET LISTED BELOW+

NOTE:

CYS WILL BE PLACED IN THE LPDR FOR THE FO ING ZIMMER 5 - 5 NINE. MILE POINT.

50 4lO LIMERICK 50 WPPS 2

0 397 BAI 50- 67 SHO

~ $0 3V LA SALLE 50-373/374 1/2Ii O W~r FOR ACTION/INFORMATION INTERNALOISTRI BUTION CENTRAL FILES 2

W 9 NRC PDR LPDRIS 7

See Note A

NSIC ACRS 6

Ie SIHWELL 2

Ge LAINAS 7

J>>

KNIGHT 2

Ce ANDERSON Ie PELTIER ts pea 0 o e 7

PS'ETTER ONLY R0 DEYOUNG K>> IQIIEL Oo PARR M~ RUSHBROOK We PIKE Se VARGA LYiiICH MD

'J~

SNELL Ao BOURNIA Wo KANE

~'"MINER c.E 7

c..S AO CONTROL NUMBER 7'FI0330035

GENERAL

ELECTRI'C.-

jm,'5ItlIJIIal5 lal GENERAL ELECTRIC COMPANY 175 CURTNER AVE., SAN JOSE, CALIFORNIA95125 MC 681, (408'25-3495 NUCLEAR ENERGY EI',II')f P R0 J ECTSs'0 I V IS I 0 N MFN-040-28 January 27, 1978 U. S. Nuclear Regulatory Commission Division of Reactor Licensing Office of Nuclear Reactor Regulation Washington, D.

C.

20555 Attention:

Mr.. John F. Stolz, Chief Light Water Reactors Branch No.

3

!Q

~Ls j QJ

,Ff g 9

)g78~

'l1 Qs %I HJQQg s~~

~xssm

~ ~i~

Gentlemen:

SUBJECT:

GENERAL ELECTRIC REPORT, "ANALYTICALMODEL FOR ESTIMATING DRAG FORCES ON RIGID SUBMERGED STRUCTURES CAUSED BY LOCA AND SAFETY RELIEF VALVE RAMSHEAD AIR DISCHARGES,"

NEDO- : 21471, DATED SEPTEMBER, 1977 One hundred (100) copies of the subject report (NEDO-21471)'are being provided by General Electric for the Nark I and Nark II Owners Groups for your review as part of the respective Containment

Programs, Tasks 5.14 and A.6.

This report describes methods for estimating drag forces. on rigid struc-tural members submerged in a suppression pool c'aused by the air discharge resulting from a Loss of Coolant Accident (LOCA) or Safety/Relief Valve Ramshead.Di,scharge.

A proprietary Appendix A to this report (NED0-21471), submitted by separate letter, contains the proprietary information referenced in the text of this report.

Any questions regarding this report should be directed to L. H. Frauenholz, the Nark II Containment Licensing Engineer, (408) 925-2623.

Sincer y

L. J.

Sobon, Manager BWR Containment Licensing Containment Improvement Programs LJS:jg/101

Enclosures:

100 cc:

C. J.

Anderson (NRC)

L. S. Gifford (GE Bethesda)

I. A. Peltier (NRC) 7gO'~3OO35 H. C. Brinkmann (Mark II Owners Group)

J.

C. Guibert (NRC)

R. L. Tedesco (NRC)

~.,~c ~~

III i

C