STANDARD DISTRIBUTION INCOMING MATERIAL RELATING TO IX CONTAINMENT UA. NUCLEAR AEGULATORV MMISSION NRC FOAM 196 l2<d)

NRC DISTRIBUTION I oA PART 50 DOCKET MATERIAL Oo ET NUMBEA 35&?BRIANÃ%

TOP ICAL REPORT Mr. John F. Stolz General Electric San Jose, CA 95125 L.J.

Sobon DATE OF DOCUMENT 01/31/78 DATE AECEIVED 02/08/78 Q

LETTER

'OAIGINAI Qcopv QNoToAIzED QUNClASSIFIED PROP'NPUT FOAM NUMBER OF COPIES RECEIVED fsrcs~e&

LETTERS OF INCORPORATION WILL BE'LACED IN EACH DOCKET LISTED BELOW NOTE'YS WXLL BE PLACED IN THE LPDR FOR THE FOLLOWING:

ZIMMER 50-358'INE'XLE POINT'0-410 LXMERXCK 50-352/353 WPPS-2 BAILLY 50<<367 SHOREHAM

. $0-342 LA SALLE 50>>373/374 jc01 02/09/78 FOR ACTION/I o&scRIPTIDN Requesting withholding pursuant to 2 ~ 790 Info. ~.Trans The Following:

NEDE>>21730 Rept entitled: "Mark XI pressure suppIression. containment systems - loads on suIbberged structures - an application mem-orandum"~

dtd December 1977...w/att Affidavit (Proprietary) of Glenn G. Sherwood, Notorized 01/31/78.

~ ~.

2p + 4p +1/8" NFO RMATION CENTRAL FI S

2 W 9 NRC PDR C-~

LPDRIS 7~

Se Note A o C

NSIC ACRS 6

I>> SIHWELL 2

G>> LAINAS 7

J>>

KNIGHT 2

C>>

ANDERSON I>> PELTIER s

o ac INTERNAL0 Rl BUTION LETTER ONLY R>>

DEYOUNG D>> VASSALID K>> KNIEL 0>>

PARR J>>

T R

TEDESCO M>> RUSHBROOK W>> PIKE ST VARGA LYNCH MD

~Mo2.

J>>

SNELL A>> BOURNIA W>>

KANE S ~ MINER EXTERNAL DISTRIBUTION CONTROL NUMBER Wh-~

7-0400037 ~

~

~

GENEIIAL;'LECTI5[CfLgogym GENERAL ELECTRIC COMPANY, 175 CURTNER AVE., SAN JOSE, CALIFORNIA95125 MC 681, (408) 925-3495

~ff)Nl) J)c)LP CHIRP)E,N E R G Y PROJECTS DIVISION MFN-051-78 January 31, 1978 U. S. Nuclear Regulatory Commission Division of Reactor Licensing Office of Nuclear Reactor Regulation Washington, D.C.

20555 Attention:

Mr. John F. Stolz, Chief Light Water Reactors Branch No.

t

'c Fpaa 1978~

g "Mo~~~lqy

~/jg Gentlemen:

SUBJECT:

References:

"NARK II PRESSURE SUPPRESSION CONTAINMENT SYSTEMS-LOADS ON SUBMERGED STRUCTURES - APPLICATION MEMORANDUM,"

NEDE-21730, DATED DECEMBER 1977 1.

Letter with report, "General Electric Report,

'Analytical Model for Estimating Drag For'ces on Rigid Submerged Structures Caused by LOCA and Safety Relief Valve Ramshead Air Discharges,'ED0-21471, dated September, 1977," to J.

F. Stolz (NRC) from L. J.

Sobon (GE). dated January 27, 1978.

2.

Letter with report,, "General Electric Report,

'Analytical Model for Liquid Jet Properties for Predicting Forces on Rigid Submerged Structures,'EDE-21472, dated September, 1977," to J.

F. Stolz (NRC) from L. J.

Sobon (GE), dated January 26, 1978 Seventy (70) copies of the subject report (NEDE-21730) are being provided by General Electric for the Mark II Owners Group for your review as part of the Mark II Containment Supporting

Program, Task A.5.

This report provides guidance for the application of the analytical models (References 1 and 2) used to define the loading on submerged structures resulting from LOCA and SRV air-bubble and water-jet dis-charges.

The enclosed report contains proprietary information originally described in the report NEDE-21472 (Reference 2),

and included in NEDE-21730, by necessity, as part of the applications procedure, which the General Electric Company customarily maintains in confidence and withholds from public disclosure.

The information has been handled and classified proprietary by General Electric as indicated in the proprietary affidavit submitted with the source

document, NEDE-21472 (Reference 2),

0q000: 7

GENERAL IELECTRIC Mr. J.

F. Stolz Page 2

January 31, 1978 and the request is hereby made that NEDE-21730'e withheld from public disclosure in accordance with the provisions of 10CFR2.790.

The non-proprietary version of this report (NEDO-21730) will be provided in February, 1978.

Any questions regarding this report should be directed to L. H. Frauenholz, the Mark II Containment Licensing Engineer, (408) 925-2623.

Sincerel L. J.

Sobon, Manager BWR Containment Licensing Containment Improvement Programs LJS:daj/100-101

Enclosures:

70 cc:

C. J.. Anderson (NRC)

H.

C. Brinkmann (Mark II Owners Group)

L. S. Gifford (GE-Bethesda)

I. A. Peltier (NRC)

R. L. Tedesco (NRC)