Text
NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES 1
- a. CERTIFICATE NUMBER
- b. REVISION NUMBER
- c. DOCKET NUMBER
- d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9328 7
71-9328 USA/9328/AF-96 1
OF 3
- 2.
PREAMBLE a.
This certificate is issued to certify that the package (packaging and contents) described in Item 5 below meets the applicable safety standards set forth in Title 10, Code of Federal Regulations, Part 71, Packaging and Transportation of Radioactive Material.
b.
This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be
- 3.
THIS CERTIFICATE IS ISSUED ON THE BASIS OF A SAFETY ANALYSIS REPORT OF THE PACKAGE DESIGN OR APPLICATION
- a.
ISSUED TO (Name and Address) b.
TITLE AND IDENTIFICATION OF REPORT OR APPLICATION Orano Federal Services LLC 505 S. 336th Street, Suite 400 Federal Way, WA 98003 Packaging Technology, Inc., application dated August 28, 2006, as supplemented.
4.
CONDITIONS This certificate is conditional upon fulfilling the requirements of 10 CFR Part 71, as applicable, and the conditions specified below.
- 5.
- a.
Packaging (1)
Model No.:
TN-55 (2)
Description The Model No. TN-55 packaging is designed to transport unirradiated uranium oxide powder. The packaging consists of a 55-gallon drum within an overpack. The unirradiated uranium oxide powder is transported inside the drum. The 55-gallon drum is a DOT specification 7A Type A drum with a reinforced closure system and ceramic gasket. The overpack for the drum has an outer surface of nominal 18-gauge galvanized carbon steel, and a reinforced fiberglass liner. The void space between the liner and outer surface is filled with a polyurethane foam. Forklift pockets, made of 12-gauge galvanized carbon steel, are located on the bottom of the overpack. The nominal outside dimensions of the overpack are 32 inch diameter and 51-5/8 inch height. The maximum gross weight of the package is 1,010 pounds.
(3)
Drawing The packaging shall be constructed and assembled in accordance with AREVA Drawing No. 60699-SAR, Revision No. 1, sheets 1 through 4.
NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES
- 1.
- a. CERTIFICATE NUMBER
- b. REVISION NUMBER
- c. DOCKET NUMBER
- d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9328 7
71-9328 USA/9328/AF-96 2
OF 3
- b.
Contents (continued)
(1)
Type and Form of Material Unirradiated uranium oxide powder with a maximum moisture content of 2 percent.
The maximum enrichment is 1.2 weight percent U-235. The content may be packaged in plastic packaging or with other plastic material within the 55-gallon drum, provided the total plastic per drum does not exceed 1,307 grams water-hydrogen equivalent or (1,000 grams of polyethylene). Materials with a hydrogen density greater than water are not authorized, with the exception of polyethylene.
(2)
Maximum Quantity of Material per Package Up to 650 pounds (295 kilograms) of unirradiated uranium oxide powder per package.
- c.
Criticality Safety Index:
1.7
- 6.
Transport by air is not authorized.
- 7.
In addition to the requirements of Subpart G of 10 CFR Part 71:
- a.
Each package shall be prepared for shipment and operated in accordance with the Package Operations, in Chapter 7 of the application.
- b.
Each packaging shall be tested and maintained in accordance with the Acceptance Tests and Maintenance Program, in Chapter 8 of the application.
- 8.
The package authorized by this certificate is hereby approved for use under general license provisions of 10 CFR 71.17.
- 9.
Revision No. 5 of this certificate may be used until March 31, 2018.
- 10.
Expiration date: April 30, 2022.
NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES
- 1.
- a. CERTIFICATE NUMBER
- b. REVISION NUMBER
- c. DOCKET NUMBER
- d. PACKAGE IDENTIFICATION NUMBER PAGE PAGES 9328 7
71-9328 USA/9328/AF-96 3
OF 3
REFERENCES Packaging Technology, Inc., application dated August 28, 2006.
Supplement dated: January 31, 2007, November 26, 2007, October 31, 2011, March 5, 2012, and February 7, 2017.
Orano Federal Services LLC application dated May 15, 2018.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION
/RA/
John McKirgan, Chief Spent Fuel Licensing Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards Date: 6/19/2018