ACCELERAT:.0 DOCUl\\1ENT DIS'l'ru.BU1'10N SYST'EM REGULArrWIP£ INFORMATION DISTRIBUTIO.YSTEM (RIDS)
ACCESSION NBR:9304220166 DOC.DATE: 93/04/19 NOTARIZED: NO DOCKET#
FACIL:50-281 Surry Power Station, Unit 2, Virginia Electric & Powe 05000281 AUTH.NAME AUTHOR AFFILIATION BOWLING,M.L.
Virginia Power (Virginia Electric & Power Co.)
RECIP.NAME RECIPIENT AFFILIATION Document Control Branch (Document Control Desk)
SUBJECT:
Provides notification of SG tubes plugged during outage as precautionary measure.
DISTRIBUTION CODE: A047D COPIES RECEIVED:LTR.=1 ENCL J2_ SIZE:~~'~~-
TITLE: OR Submittal: Inservice/Testing/Relief from ASME Code NOTES:lcy NMSS/SCDB/PM.
RECIPIENT ID CODE/NAME PD2-2 LA BUCKLEY,B INTERNAL: ACRS NUDOCS-ABSTRACT OGC/HDS2 RES MILLMAN,G EXTERNAL: EG&G BROWN,B NRC PDR NOTES:
COPIES LTTR ENCL 1
2 6
1 1
1 1
1 1
NOTE TO ALL "RIDS" RECIPIENTS:
.RECIPIENT ID CODE/NAME PD2-2 PD NRR/DE/EMEB
~~' 01
~EfS'""/D'S~/EIB EG&G RANSOME,C NSIC COPIES LTTR ENCL 1
1 1
1 1
1 1
PLEASE HELP US TO REDUCE WASTE! CONTACJ' THE DOCUMENT CONTlWL DFSJ..:,
ROOM Pl-37 (EXT. 504-2065) TO ELIMINATE YOUR NAME FROM DlSTRiBlJT!ON LISTS FOR DOCUMENTS YOU DON'T NEED!
TOTAL NUMBER OF COPIES REQUIRED: LTTR 22 ENCL 05000281 R
l D
s I
A D
D s
R I
D s
i A1 D
D s
VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 April 19, 1993 United States Nuclear Regulatory Commission Attention: Document Control Desk Washington, D. C. 20555 Gentlemen:
VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNIT 2 STEAM GENERATOR TUBE INSPECTION REPORT Serial No.93-209 NLJRPC Docket No.
50-281 License No. DPR-37 Planned inservice inspection of the Surry Unit 2 "B" steam generator was completed during the 1993 refueling outage. In accordance with Surry Power Station Technical Specifications, Section 4.19.F.a, this letter provides notification of the steam generator tubes that were plugged during the outage. In steam generator "B," two tubes (Row 40/Col 60 & Row 33/Col 63) were plugged as a precautionary measure.
If you have any questions concerning these results, please contact us.
Very truly yours, jtlL_/]~
M. L. Bowling, Manager Nuclear Licensing and Programs cc:
United States Nuclear Regulatory Commission Region II 101 Marietta Street, N. W.
Suite 2900 Atlanta, Georgia 30323 Mr. M. W. Branch NRC Senior Resident Inspector Surry Power Station
~-~- ________ ()_OQ 0_1_~~ --~
9304220166 930419 -
1 PDR ADOCK:05000281 P
.. PDR
- ~------- ---------* - *-'--- *------