ML18153D114

From kanterella
Jump to navigation Jump to search
Application for Amends to Licenses DPR-32 & DPR-37,changing TS to Modify Acceptance Criteria for Functional Testing of Anchor/Darling Mechanical Snubbers to Reflect Replacement of Pacific Scientific Snubbers W/Anchor/Darling Snubbers
ML18153D114
Person / Time
Site: Surry  
Issue date: 09/04/1992
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML18153D115 List:
References
92-580, NUDOCS 9209150018
Download: ML18153D114 (3)


Text

VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 September 4, 1992 United States Nuclear Regulatory Commission Attention: Document Control Desk Washington, D. C. 20555 Gentl~men:

VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNITS 1 AND 2 Serial No.

NO/ETS Docket Nos.

License Nos.

PROPOSED TECHNICAL SPECIFICATION CHANGES ACCEPTANCE CRITERIA FOR MECHANICAL SNUBBER TESTING 92-580 50-280 50-281 DPR-32 DPR-37 Pursuant to 1 O CFR 50.90, the Virginia Electric and Power Company requests amendments, in the form of changes to the Technical Specifications, to Operating License Nos. DPR-32 and DPR-37 for the Surry Power Station Units 1 and 2, respectively. Over the last several outages the original Pacific Scientific mechanical snubbers have been replaced with Anchor Darling snubbers. Therefore, the proposed changes will modify the acceptance criteria for functional testing of the Anchor Darling mechanical snubbers. The proposed changes are included in Attachment 1.

This request has been reviewed and approved by the Station Nuclear Safety and Operating Committee and the Management Safety Review Committee. It has been determined that the proposed changes do not involve an unreviewed safety question as defined in 1 O CFR 50.59 or a significant hazards consideration as defined in 1 O CFR 50.92.

A discussion of the changes and the basis for our no significant hazards consideration determination are included in Attachment 2.

Very truly yours, Q. r:: OJ/~---

fw W. L. Stewart Senior Vice President - Nuclear Attachments

1. Proposed Technical Specification Change
2. Discussion and Significant Hazards Consideration Determination

,,,----9209150018 920904 1

  • PDR ADOCK 05000280 p

PDR

~tj\\}! I '

cc:

U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, N. W.

Suite 2900 Atlanta, Georgia 30323 Mr. M. W. Branch NRC Senior Resident Inspector Surry Power Station Commissioner Department of Health Room 400 109 Governor Street Richmond, Virginia 23219

COMMONWEAL TH OF VIRGINIA )

)

COUNTY OF HENRICO

)

The foregoing document was acknowledged before me, in and for the County and Commonwealth aforesaid, today by J. P. O'Hanlon, who is Vice President - Nuclear Operations, for W. L. Stewart who is Senior Vice President - Nuclear, of Virginia Electric and Power Company. He is duly authorized to execute and file the foregoing document in behalf of that Company, and the statements in the document are true to the best of his knowledge and belief.

Acknowledged before me this f-1/i day of~k), 199..1._.

My Commission Expires: (d/~ 3/

, 19<ref.

rffl* ~&f/_,

Notary ublic