VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 August 24, 1992 United States Nuclear Regulatory Commission Attention: Document Control Desk Washington, D. C. 20555 Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNITS 1 AND 2 INDIVIDUAL PLANT EXAMINATION -

REQUEST FOR ADDITIONAL INFORMATION ON RESOLUTION OF GENERIC ISSUE Gl-23 Serial No.

NL&P/CGL Docket Nos.

License Nos.92-501 RO 50-280 50-281 DPR-32 DPR-37 In a letter dated July 17, 1992, the NRC requested additional information on the Surry Individual Plant Examination (IPE) regarding resolution of Generic Issue Gl-23, "Reactor Coolant Pump Seal Failures." In a telephone conversation between Mr. B. C.

Buckley, the NRC Project Manager, and a member of my staff, we requested and were granted additional time to prepare our response to this request.

The additional preparation time was requested to ensure that Station Blackout, lnservice Inspection, and other issues related to reactor coolant pump seals are more thoroughly addressed. A secondary reason for requesting the additional time is that the same personnel preparing this response are also actively involved in meeting the schedule for preparation of the North Anna IPE report.

As agreed to in the August 18, 1992 conversation, we will provide the response to your request for additional information by September 24, 1992.

Very truly yours, vJL~

W. L. Stewart Senior Vice President - Nuclear

/-- - -"- --

~*...

... 9209010120. 920824___

  • n* *

. : i -: PDR - _: ADOCK. 05000280

.. *P.

PDR ft()()/

'fl

'~...

cc:

U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, N. W.

Suite 2900 Atlanta, Georgia 30323 Mr. M. W. Branch NRC Senior Resident Inspector Surry Power Station

__J