- 10 CFR 20.407 VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 March 27, 1992 Director, Office of Nuclear Regulatory Research United States Nuclear Regulatory Commission Washington, D. C. 20555 Gentlemen:
VIRGINIA ELECTRIC AND POWER COMPANY Serial No.92-181 NURPC Docket Nos. 50-280 50-281 72-2 License Nos. DPR-32 DPR-37 SNM-2501 SURRY POWER STATION UNITS 1 AND 2
- INDEPENDENT SPENT FUEL STORAGE INSTALLATION ANNUAL WHOLE BODY EXPOSURE REPORT ANNUAL REACTOR COOLANT IODINE REPORT Pursuant to Title 10, Code of Federal Regulations, Section 20.407 (a)(1 ), and Surry Technical Specification Section 6.6.A.2.a, Virginia Electric and Power Company submits the attached.reports of Annual Whole Body Exposures for the Surry Power Station, for the calendar year 1991.
In addition, this correspondence confirms* that no annual report of sp*ecific activity analysis is required for 1991 pursuant to the reporting requirements of Surry Technical Specification 6.6.A.2.b. The specific activity of the reactor coolant for Surry Power Station Units 1 and 2 did not exceed 1.0 µCi/cc DOSE EQUIVALENT 1-131 or 100/ E..
µCi/cc as stipulated in Surry Tec~nical Specification 3.1.D.4 during the calendar year 1991.
Very truly yours,
'-\\~
W. L. Stewart Senior Vice President - Nuclear Attachment cc:
U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, N. W.
Suite 2900 Atlanta, Georgia 30323 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555 Mr. M. W. Branch NRC Senior Resident Inspector
,.-. Surry Power Station C --~ C :"'
- 9204010300 911231 PDR ADOCK 05000280 R
e RECORDED ANNUAL WHOLE BODY EXPOSURE REPORT SURRY POWER STATION FOR THE PERIOD JANUARY 1, 1991 - DECEMBER 31, 1991 Prepared By:_..... QJ~*
'-='=-:-'L"",,0,:4'*-~"'--*
~~*
D. W. Densmore Supervisor Exposure Control Reviewed By:._._£.~----=-..:.*~-~---~~~~---=-*~~~~~~~
B.A. Garber Supervisor Health Physics (Technical Services)
Approved By: __
ld--=l "--=-j--=-~----*
D.L. Erickson Superintendent Radiological Protection *
. I **
RECORD ANNUAL WHOLE BODY EXPOSURES (BASED ON THERMOLUMINESCENT DOSiMETRY)
SURRY POWER STATION CALENDAR YEAR l991 DOSE RANGE (MREM)
NUMBER OF INDIVIDUALS NO MEAS_URABLE EXPOSURE 1
99 100 249 250 499 500 749.
750 999 1,000 1,999 2,000 2,999 3,000 3,999 4,000 4,999 5,000 5,999 6;000 6,999 7,000 7,999 8,000 8,999 9,000 9,999
- 10,000 10,999 11,000
- 11,999
- 12,000 PLUS TOTAL NUMBER OF INDIVIDUALS REPORTED TOTAL STATION MAN-REM AS DETERMINED BY TU>
1,780 599 291 284 178 88 102 4
1 3,327 509.579
-i Work And Job Function MAN-REM EXPOSURE.WORK/JOB FUNCTION (BASED ON SELF-READING DOSIMETRY)
SURRY POWER STATION CALENDAR YEAR 1991 Number of Personnel Total Man-ll.em Station Utility Employees Employees Contract Station Utility Workers Employees Employees Reactor Operations and Surveillance Totals 852 105 829 39.328
.223 Maintenance Personnel 178 0
457
- 4. 758
.000 Operating Personnel 339 45 99 18.885
.119 Health Physics Personnel 84 7
127
- 11. 725
.019 Supervisory Personnel 147 7
111
. 2. 759
.006 Engineering Personnel 104 46 35
- 1. 201
.079 Other 0
0 0
.000
.000 Inservice Inspect Totals 58 12 238 3.192
.045 Maintenance Personnel 2
0 129
.023
.000 Operating Personnel 31 8
24
.733
.010 Health Physics Personnel 4
0 32
.034
.ooo Supervisory Personnel 5
2 12
.041
.003 Engineering Personnel 16 2
41 2.361
.032 Other 0
0 0
.000
- .000 Routine Maint Totals 586 46 1,074 153. 911
.504 Maintenance Personnel 168 0
670 90.183
.oc,o Operating Personnel 163 14 77 24.869
.124 Health Physics Personnel 81 1
181 24.780
.016 Supervisory Personnel 92 1
82 10.224
.010 Engineering Personnel 82 30 64 3.855
.354 Other 0
0 0
.000
.000 PAGE 1 Contract Workers
- 10. 952 1.181
.391 6.836 2.392
.152
.000 50.437 34.094 2.795 2.964 2.763 7.821
.000 225.715 142.823 5.281 57.426 16.007 4.178
.000*
l Totals 50.503 5.939 19.395 18.580 5.157 1.432
.000 53.674 34.117 3.538 2.998 2.807 10.214
.000 380.130 233.006 30.274 82.222 26.241 8.387
.000
Work And Job Function MAN-REM-EXPOSURE WORK/JOB FUNCTION (BASED ON SELF-READING DOSIMETRY)
. SURRY POWER STATION CALENDAR YEAR i991 Number Of Personnel Total Station Utility Contract Station PAGE* 2 Han-Rem Utility Employees Employees Workers Employees Employees Waste Process Totals 76 2
25 4.627
.006 Maintenance Personnel 18 0
8
.019
.ooo Operating Personnel 16 2
3
- 1. 73*9
.006 Health Physics Personnel 38 0
10 2.203
.000 Supervisory Personnel 4
0 4
.666
.000 Engineering Personnel 0
0 0
.000
.000 Other 0
0 0
.000
.ooo Refueling Totals 40 8
40 1.393
.159
- Maintenance Personnel 4
0 22
.266
.000 Operating* Personnel 11 7
3
.427
.089*
Health Physics Personnel 20 0
lL
.419
.000 Supervisory Personnel 3
0 2
.207
.000 Engineering Personnel 2
1..
2
.074
.070 Other 0
- 0.
0
.000
.000 Special Maint Totals 232 20
.655 20.041
.283 Maintenance Personnel 88 0
450 9.179
.000
-operating Personnel
- 53 8
38 3.. 352
.215 Health Physics Personnel*
47 o*
72 4.202
.000 Supervisory Personnel.
18 0
66 1.133
- .000 Engineering Personnel 26 12 29 2.175
.068 Other 0
0 b
.000
.ooo Contract Workers Totals
.204 4.837
,026
.045
.027
- 1. 772
.082 2.285
- .069
.735
.ooo
.000
.000
.000 1.205 2~757
~709
.975
.082
.598
.132
.551
.278
.485
.004 *
.148
.ooo
.000 60.323 80.647
.44.556
- 53. 735 4.337 7.904 2.613 6.815
- 8. 04 8.
~.181
.769 3.012
.000
.000
MAN-REM EXPOSURE WORK/JOB FUNCTION (BASED ON SELF-BEADING DOSIMETRY)
.SURRY POWER STATTON CALENDAR YEAR 1991 PAGE 3 Work And Job Function
- Number of Personnel Total Man-Rem Station Employees Total 1,844 Maintenance Persqnnel
- 458 Operating P~rsonnel 613 Health Physics Personnel 274 Supervisory Personnel 269 Engineering Personnel 23d Other 0
Utility Employees 193-0 84 8
10 91 0
Contract Workers 2,861 1,73(:i 244 433 277 171 _
0 Station Utility Contract Employees Employees Workers 222.492 L220 348.836 104.428
.000
.* 223.389 50.005
.563
- 12. 913 43.363
.035 70.053 15.030
.019 29.557 9.666
.603 12.924
.ooo
.ooo-
.000 Totals*
572. 548 327.817 63.481 113.451 44.606 23.193
.000