ML18153C591
| ML18153C591 | |
| Person / Time | |
|---|---|
| Site: | Surry |
| Issue date: | 03/21/1991 |
| From: | Sinkule M NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| To: | Stewart W VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.) |
| Shared Package | |
| ML18153C592 | List: |
| References | |
| NUDOCS 9104110248 | |
| Download: ML18153C591 (3) | |
See also: IR 05000280/1991004
Text
~-
OFFICIAL COPY
MAR 2 1 1991
Docket Nos. 50-280, 50-281
Virginia Electric and Power Company
ATTN:
Mr. W. L. Stewart
Senior Vice President - Nuclear
5000 Dominion Boulevard
Glen Allen, VA
23060
Gentlemen:
SUBJECT:
NRC INSPECTION REPORT NOS. 50-280/91-04 AND 50-281/91-04
This refers to the inspection* conducted by W. E. Holland of this office on
January 27 - February 23, 1991.
The inspection included a review of activities
authorized for your Surry facility~
At the conclusion of the inspection, the
findihgs were discussed with those members of your staff i~entified in the
report.
Areas examined during the inspection are identified in the report~
~ithin
these areas, the inspection.consisted of sel.ective examinations of procedures
and representative records, interviews with personnel, and observation of
_ activities in progress.
The enclosed I~sp~ction Report identifies activities that ,ppeared to violate
NRC requirements that are not cited; therefore, a response is not required.
We have identified an example involving an emergency service water pump where
your corrective action evaluation and performance was not timely in
response to an indication that a safety-related component was potentially
degraded.
Based on this event, discussed in paragraph 3 of the enclosed
report, we are concerned about your lack of sensitivity to precursors which
may indicate the potential degradation of safety-related components.
In accordance with 10 CFR 2.790 of the NRC's "Rules of Practice," a copy of
this letter and its enclosure will be placed in the NRC Public Document Room.
Should you have any questions concerning this letter, please contact us.
Enclosure:
(See page 2)
9104110248 910321
~-DR
ADOCK 05000280
..:
Sincerely,
ORIGINAL SIGNED BY
MARVIN V. SINKULE
Marvin V. Sinkule, Chief
Reactor Projects Branch* 2
Division of Reactor Projects
Virginia Electric and Power Company
Enclosure:
NRC Inspection Report
cc w/encl:
E. W. Harrell
Vice President - Nuclear Operations
Virginia Electric & Power Company
5000 Dominion Boulevard
Glen Allen, VA
23060
J. P. O'Hanlon
Vice President - Nuclear Services
Virginia Electric & Power Company
5000 Dominion Boulevard
Glen Allen, VA
23060
M. R. Kansler
Station Manager
Surry Power Station
P. 0. Box 315
Surry, VA
23883
M. L. Bowling, Jr., Manager
Nuclear Licensing
Virginia Electric & Power Co.
5000 Dominion Boulevard
Glen Allen, VA
23060
Sherlock Holmes, Chairman
Board of Supervisors of Surry County
Surry County Courthouse
Surry, VA
23683
W. T. Lough
Virginia Corporation Commission
Division of Energy Regulation
P. 0. Box 1197
Richmond, VA
23209
Michael W. Maupin
Hunton and Williams
P. 0. Box 1535
Richmond, VA
23212
C. M. G. Buttery, M.D., M.P.H.
Department of Health
109 Governor Street
Richmond, VA
23219
(cc w/encl cont'd - See page 3)
2
MAR 2 1 1S9i
Virginia Electric and Power Company
(cc w/encl cont
1d)
Attorney General
Supreme Court Building
101 North 8th Street
Richmond, VA
23219
Corrmonwealth of Virginia
bee w/encl:
\\..06'c11ment Control Desk
P. Fredrickson, RI!
B. Buckley, NRR
NRC Resident Inspector
U.S. Nuclear Regulatory Commission
Route 1, Box 166
Surry, VA
23883
NRC Resident Inspector
U.S. Nuclear Regulatory Commission
Route 2, Box 78-A
Mineral, VA
23117
RII:DRP
11fl-.
ARuff': tJ
03/ fl /91
RII~RY
PFr~gckson
03/?)/91
3
MAR 2 1 1991