October 22, 1993 Ms.

Camille Cook Piedmont Regional Office Water Division Department of Environmental P. o. Box 11143 Richmond, VA 23230 Quality Innsbrook Technical Center 5000 Dominion Bou/e1*ard Glen Allen, Virginia 23060 VIRGINIA POWER RE:

SURRY POWER STATION -

VA #0004090 -

CHEMICAL ADDITION CHANGE

Dear Ms. Cook:

This is to request approval from your agency for a proposed change in chemical addition for pH control in the feedwater system at Surry Power Station.

As you may be aware, maintaining specific levels. of pH in steam generation systems is essential in the control of corrosion in these systems.

Currently, ammonia is the chemical additive employed for this pH adjustment *. The proposed change will be to substitute another product, ethanolamine (Calgon Pre-Teet 7000), for ammonia.

In the feedwater systems, the target concentration of ethanolamine will. be in the range of 1. O -

3. O ppm.

Due to distribution properties under system temperature and pressure conditions, concentration in the blowdown from the steam _generators, to*

internal outfalls 181 and 191,.may increase to a maximum of 10 ppm.

At its maximum concentration in blowdown, and at the maximum blowdown rate of 70 gpm from each of six steam generators, the highest rate of discharge of ethanolamine, and its decomposition products, to the discharge canal would be 50. 4 7 pourids per day.

This is a theoretical worst case situation that would not be expected to actually occur since the steam generator blowdown is normally recovered and reprocessed for use within the steam generating system.

Ethanol amine decomposes to short chain. organic acids (acetic,*

formic, glycolic), ammonia, and other organic amines. Even without allowance for any decrease in concentration through decomposition, the concentration of ethanolamine at the outfall 001 discharge, under worst case conditions (<0.003 ppm), would be lower than the aquatic toxicity levels provided by the supplier.

The supplier's data and the product Material Safety Data Sheet are attached.

9310~80214* 93~~--~_ -a~~

PDR ADO.CK 05000280

.p PD!i

\\. '

Ms.

Camille Cook Oct:ober 22, 1993 P_age 2 e

. Please let me know as soon as possible if the Department of Environmental Quality has any objection to this chemical addition change.

Should you need additional information or have any questions about this matter, please contact Daniel James at 273-2996.

Sincerely,

~ltil-J-/!f1!___

B. M. Marshall, P.E.

Manager Water Quality Attachment cc:

Cw/attachments)

U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW Suite 2900 Atlanta, GA 30323 Re:

Surry Units 1 & 2 Docket Nos. 50-280/50-281 License Nos. DPR-32/DPR-37

  • ;:::u.:;s:.--Nue-Lea-:r;: *Ke-gura tory::Commi*ss:i.on7 Document Control Desk Washington, DC 20555 Re:

Surry Units 1 & 2 Docket Nos. 50-280/50-281 License Nos. DPR-32/DPR-37 Mr. M. w. Branch NRC Senior Resident Inspector Surry Power Station

SUBSIDIARY OF MERCK a CO, INC.

-.

  • WATER MANAGEMENT DIVISION P.O. BOX 1346 PITISBURGH, PA 15230 (412) 777-8000 FAX (412) 777-8927 OR 8104 Virginia Power lnsbrook Technical Center Nuclear Chemistry Department 5000 Dominion Boulevard Glen Allen, VA 23060-IN2SE Attention: Mr. Edward Frese

Dear Mr. Frese:

March 1, 1 993

. *_ I am providing the following available aquatic toxicity data to you at the request of our field sales representative, Mr. Craig Szymke.

PRODUCT NAME Pretect 1000 monoethanolamine AQUATIC TOXICITY DATA !ppm)

NOA*

24 hr. LC50 IDaphnia magna!: 140

. 96 hr. LC50 (fathead minnow): 125 96 hr. LC50 (bluegill sunfish): 75 No data available on formulated product. Toxicity data presented for individual*

ingredients.

I trust this information will satisfy your needs. If you should have any questions, please do not hesitate to contact Mr. Szymke or me.

BTL/mlh cc:

C. Szymke Sincerely, CALGON CORPORATION s~~~

Brian T. Laplante, Manager Toxicology and Product Safety

(

(

8 08 S3

0 OM, CALGON CORPORATION llO f/U
  • I lf9RIAL SAfErY eALQONCOAPOAATION P.O. Box 1346 Plttaburgh, PA 15230-1341

.:4 Hsi.!.r E=nargency Telephone ** (412) Tn-8000

  • J. PBQJ>U,I IPEHIIEJCAIIQN ea1lCAL DESQUfflOII: Alk*lin* eqllaaua aolutlan ID: 215 688 7017 UAIA,t~I ----------

- ~

~

~-N -

IUIIIDIAIIY Or WUICII & CO., INC, II, HAZABaDUS JNGREQIEHTS AND EXPOSURE LlftlTS Onl. LDSD (UM Den,,al LD.50 Jrwbltl ACGUII TLV

~BA m, PAGE 40 20~ ms11c, 1000 111&/k1 1WA 3 ppa.

8...,93 S'l'!L II pp..

u..,...

IJJ, IYPI~AL PHYIJC&L fROPERTIES IOJJ.tllO PODIT:

Not. avaU.ablA VAJW D!DlTY (aireU: llot. avaU.ahh S vct.\\tILZ BY NllGm:

60 (.. t.ar)

JY, FIR£ ANP EIPLQ~IQN HAZARD PaIA SPECIPIC GllAVI?V:

0.96 - 0.9a pB:

11.6

  • 12.4 IXTIJkKlllBIN IDJA1 Na~ Qn1, dry chal.cal, *ucobal" fa*, or cazbon diosid*.

UICIAI. PDlll'lGlnm IIDl:IIJMHc bHalH catat.100 ** ti&ht.in& q c:h*lcal fiH, A.. u-ccint.ained bll't&tbJ.qa 1pper1tua and'pcotactiv. clot.bi.'111 are a111at.1al.

U1* **t.*r to k**P fir**espo114 cont..tnar, cool.

fleaaablUr.y

  • 0 Spacial la&ard
  • NOME llula Cilia l~l.iGD. &1111 1ec--ndat.lon1 ut fa.rt.h hHa1n are bal111Va4 t.o 'be ac:cur11L* ** of tJla dat.e haraot, CALOCII CICIUmAUCII tWCl3 IO tMDAHn Wltl R!Snct IIEU'ffl AND t111!la.AIHS AU. 1.WtUT'f ~

Ul-IARCE tBIJiEaf, Pqa 1 of 4 Dat.a:

ll/2/92 2

CALGON CORPORATION IO, 2 1 s see 70 1.7 e

e

v. f,EAtXl'i!IY DAT8 QJDUCAL !'UIILITY; St.able BAMJIDClUI JOLYHEIULU'Zat:

WJ.11. 1111t. OCC1ilr CC'11l'UOIII TO A~ID:, Ovuhe*t.i.q DaltfATZIILITY:

ltrt:ma o:sJ.d.l.sere, *t.iaaa Hid&, *l-in1111, coppu

~

DEOC111'GtZTZClR l'BCDUC'rSr.-.i*, nitro11.n o:sides, cubocl 111e1noxJ.de, and cedkm <tl.ol'l.d*

YJ I HEALTH HAZARD PATA fflIHARY JIOCITES OP IMDY:

Eye uid lllcin cont.1c:t, 1ng111t.ion, inh*L11t.1oro, all.in.aaoci:,t.ion T.oUIGET OIGAKS:

1yd, l.una,a, lJ.v*i:, IEJ.cln-i,a, akin, CNS, uproii\\lct.ive ayst.4111 CANG!R!

Hu* caue* *avu* eya dUIA&*,

Hay b* haziat11J. lf ***U.0-ad.

~

cau** *~in and ra1p1rat.ory tract irritation.

En'ICTI a, OVIJllll"OIIMl:

Qal.

!'I! CQffACf:

"nib p¥Geact. would b* ei,:pecUd t.o cauae Hvn* J.tdt.at.ion upon corit.act wit.ti th* eye and po.. t.bq pel:IIIIMDr. d1111ag*,

SK.llt CO!CTACT:

l'hU product. sou.J.d c;auu akin itrit&U(ll1, HpeoialJ.y upan proJ.on&*d or rai,.. t.ed expoa11n. ly C6BA deti11J.t:.Lon, pure 11111noat.haMLaiun* is toxic by akin ab1orpt.l<>11.

Fro1cnaad oi: widaspraad akln cont.met may r**ult 1n t.he abaorption of hetm!ul 11110unl1 of mat*rial., Th*n i* nei evJ.denca t.hat. monoat.hanolaatn* 1:an caua* alhrg!c ca1\\\\,act, dU1Nt.U.b.

Ifi1G1Sf1(la I 1JIIW.AIJGI; lofiDS lo.: 8ac.4*D4-1t-U Ba111d on~* acut.* ore~ IJ>50 tor ethanol.1111ln*, t.hia p~oduct. wuuJd b* con*ld*r*d.to be

,i11ht.Ly t.o:sJ.e 'b1 ina**t.lon.

Sw*llowina th* product... Y cau** chaonic&l burn* or th*

aiout.h, ~oat., Hopha1u1, end 1tC11M1ch, Other *YIIPto!M could J.nclt,de nauHa, Vltlna.

d1ar~h.., diaain*** anu dr0111aiPa11.

lrMt.bin& of product. v*por oe !ILi.at. may HUH i.uit*t.iac1. wU,h cO\\lgh~na and d.111c(GCC1rt. ln th***** ~

end chHt.. In antaal.aper&a.u, aldl*cui.41 hiah leval. 111po111rH t.o

  • ~~

vepor *nd lli*t. prodticecl pullionary c1-..e, l*t.hUIY.nit aalll9 nonapecUJ.c d*1enera1uve chanatt in th* JJ.ver and ktdn*Js. Lab tHU hav* touiui auianal*in* to b*

a Clllt.Hl 11a1¥GUI syatn at..LDlllnt. at. low do1as. and a ClfS dap.uuant. at. lat.hal doH*.

ProlOa&-4 -,oauce t.o mode;-at*lY hU.h vapor cqtW:ent.ut.~ona *IY cauu tocal inJ~ to th*

r***Ara&osy t&'ML.

However, t.h* unto~ t.i:rl.t1111U, propart.31' of at.henol.ULJ.n* vapnu ~ould 11ve 1d~1t.e wani1na of a pot.111ttel acute ibhalat.ton crvereapoaur* 11tu*~lon.

P*1* 2 af II Oa~a.

ll/2/B.2 PAGE 3

l f

(

(

~

(

SEP-0e-93 14:20 FROM, CALGON CORPORATION 10, 21s see 7017 e

e YI, HEALTH HAZARD DATA (continued)

Ro Appllcabla 1n£uC1D&ticn\\ *** found conc*111in1 any pot*nt.i*l health *fC*et.1 rea11lLl.,_ frnm aubehran1c or chronic llrposur* to t.h1 product.

In 1piL1 of at.hanol1111!n*'* Wida ua* 1n indu1t.ry, no rep0rt1 nC injury to wotkera have bHn fou11d.

Adv1u1 nproduc:t.lv* *ff*ct.s h*v* bHn d-,111t.r1tad u, r11t.a fed soo 111,1/kl ot 1thanul1111i.11* bat.ween day II 11nd 15 of pugn111o:y.

CI.R.Cll<<JGIRICITY:

lfl'P:

I>Ji.C:

OSHA:

No ln&rldltnta l.Lated

~o iriar*dL1nt1 liat.ad Ko in1rad11nt.1 ll1t1d

-.is RAT.IKGS:

lfealt.h

  • 3..

tl1111111blht.y

  • 0 Raac:t1Vi.ty
  • 0 P1r10111l rrotectiva EqulpmanL
  • to h* auppll*d by user dapandlna on u11 ccndltion,
  • nu:, *re 1-'(ltentlal chrnr,lc hult.h athcts tu conaidai:.

111, APPLICABLE CONTROL MEASURES Al'fROl'IUATI llltOI!HIC J'RAC1'ICE.";;

Do not. 1*t. in *Y**.

AvQld contar.l, W.l.th lsln and clothh**.

Avald bn"Lhlq vapor,,.. rDJ. st..

P!R.9aW. PROTEC:'rIVE EQII I H'IENT:

IYI: l'RO?!CTJ:Olf:

Chma.l.cal 1p\\.11b go111u n;i;it PROT!CTIOII:

Ch.alcal n11ht.ant. &1.nvas RE!PIRATORl l'RQT'ECTION:

?C a1rborn* conc1ntration1 axc11d publ11h1d *icpasur* limits, u1~ a NI06H approv..S r*apiret.or in accordanc* with CSIIA r*spltatory prDLICt.ion r*qu1remant.s (29 CF1l 1810,lllo).

w:lllK 1'RACTICES:

/I.fl *Y* wash at.at.ion ahould ba avdlu'1.e in th* 1lmlld111t.* UH nC uafl.

ILUIDLING AlfD STORAGE l'RECAIJTTOIIS:

Uu with ad.,quat.1 vant.1l1tio11.

Waoh Lhoroughly a!t1r handl1na.

K,ep *ant.alnM doaed.i,an not. i11 uH.

!HGIIUDIHO cotnllOl.5:

L:ical. 1xh.11ust vent1l11l.loh may be.i:equiud in addit.ion to a****nl rnan vant.ihLLon.

VIII. FIRST AID Erl CDlff.ACT:

Xn CIH ar contact., imaldht.*llf' flu1h *.,... wlt.h plant:, of Wat.et fer at least. 15 mlnuLal, Seall.

m1dical aid 1.maec11at*l1.

  • SlI1I c:atTACT; In UH of conhct., fl111h altln with pl.mt.y of waur, ll-* cont1111i.nat.ad clot.hlng.

/;aak aaacllnL aid if lrrltat.ion par1i1t.1.

W11h clot.hi.at b1faca reu11.

IIIIJATIOK:

If 1n1a11owed. do NOT induce Vtllllitina, Cive L*caa quant.tt1e1 of **tar.

iaine4Uat.ely.

  • If.var 9lv1 ~yt.h.1.na b:, IIIOUth tu an unce1nac1ou1 pauon.
iau 111..S lc
el a Id If 1nhal*d, r-* t.a t.i
11h eir.

IC nee. brHUlh*I, 11iva acti.ficl.al r.. plr&tion.

I! hr**Lhin1 h cu.u:1c:ult., ah* UX)'i~il.

S=cill==dhcil. e.l.d.

Pq* 3 ol: ~

Dal.*:

11/.!/Qa PAGE 4

e e

'. IX, SPILL OR LEAK *eeo,EDURES/WASTE DISPOSAL SUPS ~* llf. TAX!:!f IF MATERIAL IS Rn.l!AS!D ClR SP'!'UE!J:

Wearln& 1-ppropriat.a p1r1onaL pro~actlv* aautp,,ent.,

c~taln 1plll. coLlact qpLo tnart ab10~01nt. and pl*c*

into 111ltlbla container.

WASTE UISPClSAL:

Ol.*po** of 1n accordanea with J.ocll, *tat.a and f*de.rll reg11bt.lon1.

Avoid di1ch1r&* to natural wat.ar1.

X, REGULATORY STATUS TSCA STATUS:

The ingi:a,Uant.l at thLs produ,:t ara lhtad on the ToJ:lC Suliatanc:es Control Act (TSCA>

Che111~caL Subatancaa Inventory.

Cl:ltCLA report.able q11u1t.U.y ut El'A hazardcu1 sl&bst11ncu in produ~t:

Nc1111 AAfCA tITLt: I IT :

$1cUun 311 u,d 312 ll111lt.h &nit Phy1ical R11aai:de:

I111111dh1t1 oalayad Fir*

!yesl

[ya1)

(no I DOT Ct.Ar.SifICATtOH:

lltaard Claaa:

Corro1iva material Propar ahippl.nA name:

Monoathanolinln* *alution

  • ID nun!bu:

UN 2491 Lal,11:

Corraal.ve Pra11ura (na l t'IIEPARF.D BY:

.t.E:.,.,,, J..,,....1aH~n,:.;l,w.:1..._ _______________ _

6.ZC4/AX HSDS Ko.:

82.C4*04-1&*92 RaacUvlty (no 1 Det.a:

U/2/11:.l r

t

('

(

(