e VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 August 30, 1994 United States Nuclear Regulatory Commission Attention: Document Control Desk Washington, D. C. 20555 Gentlemen:
VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNITS 1 AND 2
SUMMARY
- REPORT FOR Serial No.
93-663A EE/TCC-CGL R1 Docket Nos.
50-280 50-281 License Nos. DPR-32 DPR-37 INSPECTION AND REPAIR OF ELECTRICAL PENETRATIONS In a letter (Serial No.93-663) dated January 21, 1994, Virginia Electric and Power Company indicated that a summary report of the inspection and repair of electrical penetrations would be submitted within 90 days of completion of the Surry Power Station Unit 2 work, which was completed during the June 1994 steam generator chemical cleaning outage. The summary report is provided in the attachment. The legend for the attachment explains the report designations. To summarize the results, 211 O Units 1 and 2 electrical penetrations were inspected and 1031 penetration repairs were required. The majority of the repairs were required due to an inadequate depth of the fire stop sealant material. It should be noted that a station deviation report was written for the barriers that required repair, and a continuous fire watch was posted until the repairs were completed.
If you have questions or require additional information, please contact us.
Very truly yours,
~uV.OJ/~
1:James P. O'Hanlon Senior Vice President - Nuclear Attachment - Surry Electrical Penetration Inspection and Repair Summary cc:
U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, N. W.
Suite 2900 Atlanta, Georgia 30323 Mr. M. W. Branch NRC Senior Resident Inspector Surry Power Station 940908029 i~ 94-(1830
-~ -,-
PDR ADOCK 05000280 Q
~()a\\
\\'\\'. \\~
FA 1
2 3&4 5
e ATTACHMENT SURRY ELECTRICAL PENETRATION INSPECTION AND REPAIR
SUMMARY
BARRIER NO.
CVT1A CVT18 CVT1C CVT1D CVT1E CVT1G CVT1H CVT1J MCCAUX MCCMSVH CVT28 CVT2C CVT2D CVT2E CVT2G CVT2H CVT21 MCCAUX MCCMSVH ESGR1-2 ESGR2A ESGR28 ESGR2C CR1-F ACR1-F MCR1-F CR2-F ACR2-F MCR2-F MCRA-F S8-STAIR1 S8-STAIR2 S8-STAIR3 PEN. NOS. {#)
2676-2695 (20) 2539 (1)
Note 1 Note 1 None (0)
None (0) 2594-2608 (15) 2610-2672, 2701-2704 (67) 2540-2541 (2) 2549-2551 (3)
Total: 10a Note 1 Note 1 1886-1967 (82) 1806-1825 (20) 1789-1800 (12) 2560-2574 (15) 1831-1879 (49)
None (0) 2543-2545 (3)
Total: 181 1411-1499 (89) 1712-1716 (5) 1693-1694 (2) 1701-1705 (5)
Total: 101 2850-2941, 3391 (93) 2745-2749 (5) 2984-3456 (211) 2750-2847 (98) 2942-2948 (7) 3062-3193, 3195-3243 (181) 2950-2982 (33) 2735-2744 (10) 2727 (1) 2723-2734 (11)
Total: sso Page 1 of 4 NO. of REPAIRS 9
0 N/A N/A N/A N/A 2
35 0
3 Total: 49 N/A N/A 13 9
0 8
12 N/A 0
Total: 42 4
1 2
1 Total: 8 61 0
120 80 0
129 0
6 1
6 Total: 403
FA BARRIER NO.
PEN. NOS. (#)
NO. of REPAIRS 6
EDG1A 1001-1003 (3) 0 EDG1B 1006-1011 (6) 3 EDG1C 1013-1015 (3) 1 Total; 12 Total: 4 7
EDG2D 1019-1023 (5) 0 EDG2E 1026-1031 (6) 2 Total: 11 Total: 2 8
EDG3F 1036-1045 (10) 7 EDG3G 1051-1060 (10 0
Total: 20 Total: z 9
BR1A1 1517 (1) 0 BR1A2 1523-1525 (3) 1 BR1AB None (0)
N/A BR1AC 1535-1536 (2) 0 Total; s Total: 1 10 BR1B1 2553-2555 (3) 0 BR182 1511 (1) 0 BR1BC 1541-1542 (2) 0 Total: s Total: o 11 BR2A1 1547-1548 (2) 0 BR2A2 1553-1554 (2) 0 BR2AC 1559-1561 (3) 0 Total: z Total: o 12 BR2BC 1661-1662 (2) 0 13 SWGR12 1116-1138 (23) 8 SWGR1TB 1066-1086 (21) 1 SWGR1A 1760-1761 (2) 0 Total: 46 Total: 9 14 SWGR2TB 1091-1115 (25) 3 SWGR2A 1749-1752 (4) 1 SWGR2AX 1738-1742 (5) 0 SWGR2B None (0)
N/A SWGR2C 1731 (1) 1 SWGR2D 1723-1725 (3) 1 Total: 38 Total: 6 Page 2 of 4
FA BARRIER NO.
PEN. NOS. (#)
NO. of REPAIRS 17 ABSG (1&2) 2705-2710, 2721-2722 (8) 8 ABSB 2701 (1) 1 Total: 9 Total: 9 18A FOPH 1182 (1) 0 FOPHEM None (0)
N/A Total: 1 Total: O 28C INS-CA 2702 (1) 0 INS-CB 2703-2704 (2) 0 Total; 3 Total: *o 31 TB1-2 3245-3318 (73) 7 32 FPH 1186-1198 (13) 0 33 LOSRA 1151-1176 (19) 0 LOSRB 1146-1149 (4) 4 LOSRC 1155 (1) 1 Total: 24 Total: 5 45 MER3C None (0)
N/A MER3D 1565-1614 (50) 2 MER3E 1624-1649 (26) 0 Total: 76 Total: 2 46 CTR1TB 2270-2278 (8) 5 CTRMER1 1231-1258 (28) 4 CTR1AB 2696-2700 (5) 5 CTR1-2 1271-1319 (49) 11 CTR1-CVT 1976-1984 (9) 9 CTR1C 1986-2263 (278) 209 Total; 377 Total: 243 47 CTR2TB 1366-1385 (18) 3 CTRMER2 1331-1357 (27) 15 CTR2AB 1391-1393 (3) 0 CTR2C 2290-2538, 2557-2559 (251) 196 CTR2A None (0)
N/A CTR2-CTV 1397-1406 (10) 9 Total: 309 Total: 223 Page 3 of 4
FA BARRIER NO.
PEN. NOS. (#)
54 CPSWC 1683-1686 (4)
CPSWPRL 1669-1676 (8)
CPSWPRM None (0)
Total: 12 55 TSCA 1201-1203 (3)
TSCB 1206-1209 (4)
TSCC 1213-1217 (5)
TSCD 1221 (1)
TSCE 1226-1227 (2)
TSCF None (0)
TSCG None (0)
TSCH 2711-2720 (10)
Total: 25 Total Number of Penetrations Inspected:
211 O Total Number of Repairs:
1031 Legend:
e NO. of REPAIRS 1
0 N/A Total: 1 0
0 0
0 0
N/A N/A 10 Total: 10 FA-This is the Fire Area number that corresponds to the numbers listed in the Surry Appendix R Report. Although there are 36 areas in the Appendix R Report, only 25 of these areas are listed in the summary report. Some areas were not listed since the barriers (floor/ceiling or wall) associated with the area is common to another fire area and was inspected under the other fire area number. Also, some fire areas were omitted since their barriers do not require inspection (e.g., Units 1 and 2 containment - Fire Areas 15 and 16) or have only exterior barriers that are not required to be fire rated (e.g., Radwaste Facility - Fire Area 65).
BARRIER NO. -This is a designation that was assigned to the individual barriers for ease of tracking and are not intended to be permanent labels.
PEN. NOS. (#) - These are numerical designations that were set aside for penetrations to be inspected in each barrier and are not intended to be permanent station labels. The number in ( ) indicates the total number of penetrations inspected for each barrier.
NO. of REPAIRS - This is the number of repairs that were made for each barrier.
Note 1: These are 4 inch thick walls that will not be upgraded to provide a 3-hour fire resistance rating. The fire barrier boundary was changed by a design change so these walls are not required to have a fire rating. Therefore, these walls will not be evaluated as part of this effort.
Page 4 of 4