VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 May 13~ 1994 United States Nuclear Regulatory Commission Attention: Document Control Desk Washington, D. C. 20555 Gentlemen:
VIRGINIA ELECTRIC AND POWER COMPANY NORTH ANNA POWER STATION UNITS 1 AND 2 SURRY POWER STATION UNITS 1 AND 2 EMERGENCY RESPONSE DATA SYSTEM DATA BASE UPDATES Serial No.
EE/TJK-CGL Docket Nos.
License Nos.94-296 RO 50-338 50-339 50-280 50-281 NPF-4 NPF-7
. DPR-32 DPR-37 As a result of a Surry Emergency Response Facility problem report, modifications to the point names of several Emergency Response Data System (EROS) points were necessary. It was discovered that incorrect system codes had been assigned to the containment sump level inputs. This correction, which affects one point per unit, was made at both Surry and North Anna. The changes are detailed in the Data Point Library (DPL) reference file forms contained in Attachments 1 and 2 for Surry Units 1 and 2 and North Anna Units 1 and 2, respectively. Attachments 3 and 4 provide revision summaries (change reports) for the affected points for Surry Units 1 and 2 and North Anna Units 1 and 2, respectively. The updated data base files are also provided in the dBase IV format on Attachment 5.
If you have questions regarding this information, please contact us.
Very truly yours, M. L. Bowling, Manager Nuclear Licensing & Programs Attachments:
1. Updated DPL Forms for Surry Units 1 and 2
- 2. Updated DPL Forms for North Anna Units 1 and 2
- 3. DPL Revision Summaries for Surry Units 1 and 2
- 4. DPL Revision Summaries for North Anna Units 1 and 2
- 5. Updated DPL Data Base Files for Surry and North Anna in dBase IV Format r-~,...
- 1701..,7 940513 9405
-~-
e cc:
U. $. Nuclear Regulatory Commission - Attachments 1 - 4 Region II 101 Marietta Street, N. W.
Suite 2900 Atlanta, Georgia 30323 Mr. M. W. Branch - Attachments 1 - 4 NRC Senior Resident Inspector Surry Power Station Mr. R. D. McWhorter - Attachments 1 - 4 NRC Senior Resident Inspector North Anna Power Station
- NUS Corporation / El Division - Attachments 1 - 5 P. 0. Box 59736 Idaho Falls, Idaho 83405 Attention: Mr. Tony LaRosa
e ATTACHMENT 1 UPDATED DPL FORMS FOR SURRY UNITS 1 AND 2
I.....
PRINTED 04/29/94 DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:*
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
INSTRUMENT FAILURE MODE:
TEMPERATURE COMPENSATION.
FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
04/29/94 SUl N/A CTMNT SMP WR L1RS002C
- STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE CONTAINMENT WR SUMP LEVEL CONTAINMENT SUMP WR LEVEL A
FT 1 FT= 58343 GALLONS 0.173 9.0 TNKBOT N/A p
2 AVERAGE -
SEE SYSTEM DESCRIPTION RECIRC SPRAY SUMP-SEE SYSTEM DESCRIPTION VARIABLE N/A N/A N/A N/A The valid wide range signals are averaged (2 signals if all are valid).
If neither signal is valid, this point is.
- marked invalid.
~
I N
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
- ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
INSTRUMENT FAILURE MODE:
TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
04/29/94 SU2 N/A CTMNT SMP WR L2RS002C STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CONTAINMENT WR SUMP LEVEL CONTAINMENT SUMP WR LEVEL A
FT 1 FT= 58343 GALLONS 0.173 9.0 TNKBOT N/A p
2 AVERAGE -
SEE SYSTEM DESCRIPTION RECIRC SPRAY SUMP-SEE SYSTEM DESCRIPTION VARIABLE N/A N/A N/A N/A The valid wide range signals are averaged (2 signals if all are valid).
If neither signal is valid, this point is marked invalid.
PRINTED 04/29/94 e
e ATTACHMENT 2 UPDATED DPL FORMS FOR NORTH ANNA UNITS 1 AND 2
NI I
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES':
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERE~CE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
INSTRUMENT FAILURE MODE:
TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:.
UNIQUE SYSTEM DESC:
04/29/94 NA1 N/A CTMNT SMP WR L1RS002C STATION: North Anna UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE CONTAINMENT WR SUMP LEVEL CONTAINMENT SUMP WR LEVEL
.A FT N/A 0.0 11.33 TNKBOT N/A p
2 AVERAGE -
SEE SYSTEM DESCRIPTION RECIRC SPRAY SUMP-SEE SYSTEM DESCRIPTION VARIABLE N/A N/A N/A N/A Two transmitters. (LT-RS-151A-2 & B-2) monitor recirc spray sump level in the sump itself (0-6'8") and two additional transmitters (LT-RS-151A-1 & B-1) monitor the level above the sump itself (6'8"-11'4").
The valid wide range signals are averaged (2 signals if all are valid).
If neither signal is valid, this point is marked invalid.
PRINTED 04/29/94 e
~
N I
N PRINTED 04/29/94 DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETE;R:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
~I DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
INSTRTJMENT FAILURE MODE:
TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
04/29/94 NA2 N/A CTMNT.SMP WR L2RS002C STATION: North Anna.
UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CONTAINMENT WR SUMP,LEVEL CONTAINMENT SUMP WR LEVEL A
FT N/A 0.0 11;33 TNKBOT N/A p
2 AVERAGE -
SEE SYSTEM DESCRIPTION RECIRC ~PRAY SUMP-SEE SYSTEM DESCRIPTION VARIABLE N/A N/A N/A N/A Two transmitters (LT-RS-251A-2 & B-2) monitor recirc spray sump level in the sump itself (0-6'8") and two additional transmitters (LT-RS-251A-1 & B-1) monitor the level above the sump itself (6'8"-11'4").
The valid wide range sibnals are averaged (2 signals if all are valid)*.
If neither signal is valid, this point is marked invalid.
ATTACHMENT 3 DPL REVISION SUMMARIES FOR SURRY UNITS 1 AND 2
w I....
STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT ADDED POINT LlRS002C AT 10:34 ON 04/28/94 AS FOLLOWS:
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:.
NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
INSTRUMENT FAILURE MODE:
TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
04/28/94 SUl N/A CTMNT SMP WR L1RS002C CONTAINMENT WR SUMP LEVEL CONTAINMENT SUMP WR LEVEL A
FT 1 FT= 58343 GALLONS 0.173 9.0 TNKBOT N/A p
2 AVERAGE -
SEE SYSTEM DESCRIPTION RECIRC SPRAY SUMP-SEE SYSTEM DESCRIPTION VARIABLE N/A N/A N/A N/A PRINTED 04/29/94 e
e
(,.)
I N
STATION: Surry.
UNIT: 1 PWR.DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT DELETED POINT L1DA001C AT 10:34 ON 04/28/94.
FIELDS WERE AS FOLLOWS:
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
.GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
.ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
INSTRUMENT FAILURE MODE:
TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
08/02/93 SUl N/A CTMNT SMP WR L1DA001C CONTAINMENT WR SUMP LEVEL CONTAINMENT SUMP WR LEVEL A
FT 1 FT= 58343 GALLONS 0.173 9.0 TNKBOT N/A p
2 AVERAGE -
SEE SYSTEM DESCRIPTION RECIRC SPRAY SUMP-SEE SYSTEM DESCRIPTION VARIABLE N/A N/A N/A N/A The valid wide range signals are averaged (2 signals if all are valid).
If neither signal is valid, this poirit is marked invalid.
PRINTED 04/29/94 e
e
w I w STATION: Surry UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT L1RS002C AT 08:20 ON 04/29/94.
CHANGES WERE AS FOLLOWS:
DATE:
WAS: 04/28/94 IS: 04/29/94 UNIQUE SYSTEM DESCRIPTION:
WAS:
IS: The valid wide range signals are averaged (2 signals if all are valid).
If neither signal is valid, this point is marked invalid.
PRINTED 04/29/94 e*
w I
~
STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT ADDED POINT L2RS002C AT 10:38 ON 04/28/94 AS FOLLOWS:
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
INSTRUMENT FAILURE MODE:
TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:.
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
04/28/94 SU2 N/A CTMNT SMP WR L2RS002C CONTAINMENT WR SUMP LEVEL CONTAINMENT SUMP WR LEVEL A.
FT 1 FT= 58343 GALLONS 0.173 9.0 TNKBOT N/A p
2 AVERAGE -
SEE SYSTEM DESCRIPTION RECIRC SPRAY SUMP-SEE SYSTEM DESCRIPTION VARIABLE N/A N/A N/A N/A PRINTED 04/29/94
w I
U1 STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT DELETED POINT L2DA001C AT 10:38 ON 04/28/94.
FIELDS WERE AS FOLLOWS:
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
.GENERIC/COND DESC:
ANALOG/DIGITAL:
.ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:.
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
.NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
INSTRUMENT FAILURE MODE:
TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
08/02/93 SU2 N/A CTMNT SMP WR L2DA001C
FT 1 FT= 58343 _GALLONS 0.173 9.0 TNKBOT N/A p
2 AVERAGE -
SEE SYSTEM DESCRIPTION RECIRC SPRAY SUMP-SEE SYSTEM DESCRIPTION VARIABLE N/A N/A N/A*
N/A The valid wide range signals are averaged (2 signals if all are valid).
If neither signal *is valid, this point is marked invalid.*
PRINTED 04/29/94 e
w I
O"'I STATION: Surry UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT L2RS002C AT 08:25 ON 04/29/94.
CHANGES WERE AS FOLLOWS:
DATE:
UNIQUE SYSTEM DESCRIPTION:
WAS: 04/28/94 IS: 04/29/94 WAS:
IS: The valid wide range signals are averaged (2 signals if all are valid).
If neither signal is valid, this point is marked invalid.
PRINTED 04/29/94
e e
ATTACHMENT 4 DPL REVISION SUMMARIES FOR NORTH ANNA UNITS 1 AND 2
STATION: North Anna UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT ADDED POINT L1RS002C AT 10:24 ON 04/28/94 AS FOLLOWS:
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC EROS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
- PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
INSTRUMENT FAILURE MODE:
TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
04/28/94 NAl N/A CTMNT SMP WR L1RS002C CONTAINMEJ:IT WR SUMP LEVEL CONTAINMENT SUMP WR LEVEL A
FT N/A
- o. 0, 11.33 TNKBOT N/A p
2 AVERAGE -
SEE SYSTEM DESCRIPTION RECIRC SPRAY SUMP-SEE SYSTEM DESCRIPTION VARIABLE N/A N/A N/A N/A PRINTED 04/29/94 e
I N
STATION: North Anna UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT DELETED POINT LlDAOOlC AT 10:24 ON 04/28/94.
FIELDS WERE AS FOLLOWS:
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
- POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
- ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
NI DETECTOR POWER SUPPLY TURN-ON POWER. LEVEL*:
INSTRUMENT FAILURE MODE:
TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
03/21/91.
NAl N/A CTMNT SMP WR LlDAOOlC CONTAINMENT WR SUMP LEVEL CONTAINMENT SUMP WR LEVEL A
FT N/A 0.0
- 11. 33 TNKBOT N/A p
2 AVERAGE -
SEE SYSTEM DESCRIPTION RECIRC SPRAY SUMP-SEE SYSTEM DESCRIPTION VARIABLE N/A N/A N/A N/A Two transmitters (LT-RS-lSlA-2 & B-2) monitor recirc spray sump level in the sump itself (0-6'8") and an two additional transmitters (LT-RS-lSlA-1 & B-1) monitor the level above the sump itself (6'8"-11'4").
The valid wide range signals are averaged (2 signals if all are valid).
If neither signal is valid., this point' is marked invalid.
PRINTED 04/29/94*
e
- c::.
I w STATION: North Anna UNIT: 1 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT L1RS002C AT 08:29 ON 04/29/94.
CHANGES WERE AS FOLLOWS:
DATE:
WAS: 04/28/94 IS: 04/29/94 UNIQUE SYSTEM DESCRIPTION:
WAS:
IS: Two transmitters (LT-RS-lSlA-2 & B-2) monitor recirc spray sump level in the sump itself (0-6'8") and an two additional transmitters (LT-RS-lSlA-1 & B-1) monitor the level above the sump itself (6'8"-11'4").
The valid wide range signals are averaged (2 signals if all are valid).
If neither signal is valid, this point is marked invalid.
PRINTED 04/29/94 e
- ~
I
~
STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT ADDED POINT L2RS002C AT 10:29 ON 04/28/94 AS FOLLOWS:
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT
REFERENCE:
REFERENCE POINT NOTES:
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER*LEVEL:
NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
INSTRUMENT FAILURE MODE:
TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:
UNIQUE SYSTEM DESC:
04/28/94 NA2 N/A CTMNT SMP WR L2RS002C CONTAINMENT WR SUMP LEVEL CONTAINMENT SUMP WR LEVEL A
FT N/A 0.0 11.33 TNKBOT N/A p
2 AVERAGE -
SEE SYSTEM DESCRIPTION RECIRC SPRAY SUMP-SEE SYSTEM DESCRIPTION VARIABLE N/A N/A N/A N/A PRINTED 04/29/94
~
I u, STATION: North Anna UNIT: 2 PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT DELETED POINT L2DA001C AT 10:30 ON 04/28/94.
FIELDS WERE AS FOLLOWS:
DATE:
REACTOR UNIT:
DATA FEEDER:
NRC ERDS PARAMETER:
POINT ID:
PLANT SPEC POINT DESC:
GENERIC/COND DESC:
ANALOG/DIGITAL:
ENGR UNITS/DIG STATES:
ENGR UNITS CONVERSION:
MINIMUM INSTR RANGE:
MAXIMUM INSTR RANGE:
ZERO POINT REFER~CE:.
REFERENCE POINT., NOTES :
PROC OR SENS:
NUMBER OF SENSORS:
HOW PROCESSED:
SENSOR LOCATIONS:
ALARM/TRIP SETPOINTS:
NI DETECTOR POWER SUPPLY CUT-OFF POWER LEVEL:
NI DETECTOR POWER SUPPLY TURN-ON POWER LEVEL:
INSTRUMENT FAILURE MODE:
TEMPERATURE COMPENSATION FOR DP TRANSMITTERS:
LEVEL REFERENCE LEG:.
UNIQUE SYSTEM DESC:
03/21/91 NA2 N/A CTMNT SMP WR L2DA001C CONTAINMENT WR SUMP LEVEL CONTAINMENT SUMP WR LEVEL A
FT N/A o.o 11.33 TNKBOT N/A p
2 AVERAGE -
SEE SYSTEM DESCRIPTION RECIRC SPRAY SUMP-SEE SYSTEM DESCRIPTION VARIABLE N/A N/A N/A N/A Two transmitters (LT-RS-251A-2 & B-2) monitor recirc spray sump level in the sump itself (0-6'8") and an two additional transmitters* (LT-RS-251A-l & B-1) monitor the level above the sump itself (6'8"-11'4").
The valid wide range signals are averaged (2 signals if all are valid).
If neither signal is valid, this point is marked invalid.
PRINTED 04/29/94 e
.J::a I
O"I STATION: North.Anna UNIT: 2
- PWR DATA POINT LIBRARY REFERENCE FILE CHANGE REPORT CHANGED POINT L2RS002C AT 08:48 ON 04/29/94.
CHANGES WERE AS FOLLOWS:
'DATE:
WAS: 04/28/94 IS: 04/29/94 UNIQUE SYSTEM DESCRIPTION:
WAS:
IS: Two transmitters (LT-RS-lSlA-2 & B-2) monitor recirc spray sump level in the sump itself (0-6'8") and an two additional transmitters (LT-RS-lSlA-1 & B-1) monitor the level above the sump itself (6'8"-11'4").
The valid wide range signals are averaged (2 signals if all are valid).
If neither signal is valid, this point is marked invalid.
PRINTED 04/29/94 e