VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 March 15, 1994 United States Nuclear Regulatory Commission Attention: Document Control Desk Washington, D. C. 20555 Gentlemen:
VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNIT 1 STEAM GENERATOR TUBE INSPECTION REPORT Serial No.94-139 NURPC Docket No. 50-280 License No. DPR-32 Planned inservice inspection of the Surry Unit 1 "B" steam generator was completed during the 1994 refueling outage. In accordance with Surry Power Station Technical Specifications, Section 4.19.F.a, this letter provides notification of the steam generator tubes that were plugged during the outage. Although plugging was not required by Technical Specification requirements, the four tubes noted below were plugged as a precautionary measure in steam generator "B".
- ROW 34 34 39 43 COLUMN 17 19 23 31 If you have any questions concerning these results, please contact us.
Very truly yours,
~A~
M. L. Bowling, Manager Nuclear Licensing and Programs cc:
United States Nuclear Regulatory Commission Region II 101 Marietta Street, N. W.
Suite 2900 Atlanta, Georgia 30323 Mr. M. W. Branch NRC Senior Resident Inspector Surry P_(?wer_ ~tation __
,.'(~9P-4DOR3~~~a ii&5b~so
~: