e UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555--0001 Mr. J.P. O'Hanlon Senior Vice President - Nuclear Virginia Electric and Power Company 5000 Dominion Blvd.
Glen Allen, Virginia 23060
//ujt1>/...?q /ff 5
SUBJECT:
EVALUATION OF THE THIRD 10-YEAR INTERVAL INSPECTION PROGRAM PLAN AND ASSOCIATED REQUESTS FOR RELIEF FOR SURRY POWER STATION, UNIT 2 (TAC NO. M89085)
Dear Mr. O'Hanlon:
The staff, with technical assistance from its contractor, the Idaho National Engineering Laboratory (INEL), has reviewed and evaluated the information provided by Virginia Electric and Power Company in its letter dated March 18, 1994, related to the Third 10-year Intervai Inservice Inspection Program Plan, Revision O and associated requests for relief for the Surry Power Station, Unit 2.
Additional information was provided in your letter dated November 28, 1994.
The staff's evaluation and conclusions are contained in the enclosed Safety Evaluation.
Based on the information submitted, the staff adopts the contractor's conclusions and recommendations presented in the enclosed Technical Evaluation Report.* No deviations from regulatory requirements or commitments were identified in the Surry Power Station, Unit 2, Third Ten-Year Interval Inservice Inspection Program Plant, Revision 0~
Based on the information provided, the proposed alternatives contained in Requests for Relief Nos. SR-001, SR-007, SR-008, SR-009, SR-012, RR-2, RR-3, and RR-5 will provide an acceptable level of quality and safety and are authorized pursuant to 10CFR50.55a(a)(3)(i) with. provisions for SR-009 and RR-
- 5.
The alternative contained in SR-009 is authorized provided that at least a 10% sample of all Code Class 1, 2, and 3 integral attachments is examined and the alternative contained in RR-5 is authorized provided that one bolt, closest to the source of leakage, is removed as part of the evaluation.
Compliance with the Code requirements regarding Requests for Relief Nos. SR-005, SR-013, and RR-6 would result in a hardship or unusual difficulty without a compensating increase in the level of quality and safety and the alternatives contained in the subject requests for relief will provide a reasonable assurance of operational readiness of systems involved in the reliefs. Therefore, your proposed alternatives contained in Requests for Relief Nos. SR-005, SR-013, and RR-6 are authorized pursuant to 10CFR50.55a(a)(3)(ii) as requested.
In the case of Requests for Relief Nos. SR-002, SR-003, SR-004, SR-006, SR-010, SR-011, RR-1, and RR-4, you have demonstrated that specific Code requirements are impractical and that granting relief will not endanger life, property, or the common defense and security and is otherwise in the public interest, giving due consideration to the burden upon the licensee that
-9509Q80268 950830 PDR
'ADOCK 05000281
~
- could result if the requirements were imposed on the facility. Therefore, relief is granted for Requests for Relief Nos. SR-002, SR-003, SR-004, SR-006, SR-010, SR-011, RR-1, and RR-4 pursuant to 10CFR50.55a(g)(6)(i) as requested with the exception of SR-006.
Relief is granted for Request for Relief No.,
SR-006 provided that each Class 1 and 2 piping weld examined receives all of the required reference markings as the inservice examinations are performed.
This completes our effort on this issue and we are, therefore, closing out TAC No. M89085.
Docket No. 50-281
Enclosures:
- 1. Safety Evaluation
- 2. Technical *Evaluation Report cc w/enclosures: See n~xt page Di stri but fori o*ock*et:,:Frre,,* *.
PUBLIC *. - _ -
PDil-1 RF s~ -*varga J. Zwolinski ACRS.(4)
D. *Verrelli,: RII Sincerely,
,Liv~~
-:-1-A;--David B. Matthews, Director
-yv, Project Directorate II-I Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation FILENAME _-. C: \\AUTOS\\WPD0CS\\SU89085.AMO *Previously Concurred.
NAME SUttal DMATTHEWS DATE 08/22/95 08/'3.0 /95 COPY OFFICIAL RECORD COPY
.... could result if the requirements were imposed on the facility. Therefore, relief is granted for Requests for Relief Nos. SR-002, SR-003, SR-004, SR-006, SR-010, SR-011, RR-1, and RR-4 pursuant to 10CFR50.55a(g)(6)(i) as requested with the exception of SR-006.
Relief is granted for Request for Relief No.
SR-006 provided that each Class I and 2 piping weld examined receives all of the required reference markings as the inservice examinations are performed.
This completes our effort on this issue and we are, therefore, closing out TAC No. M89085.
Docket No. 50-281
Enclosures:
- 1. Safety Evaluation
- 2. Technical Evaluation Report
. cc w/enclosures: See next page Sincerely, Lf\\-,"1)~~ktJ
--1.___../riavid B. Matthews, Director
-;-- v~ Project Directorate II-I Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation
Mr. J. P. O'Hanlon Virginia Electric and Power Company cc:
Michael W. Maupin, Esq.
Hunton and Williams Riverfront Plaza, East Tower 951 E. Byrd Street Richmond, Virginia 23219 Mr. David Christian, Manager Surry Power Station Post Office Box 315 Surry, Virginia 23883 Senior Resident Inspector Surry Power Station U.S. Nuclear Regulatory Commission 5850 Hog Island Road Surry, Virginia 23883 Chairman Board of Supervi s*ors of Surry County Surry County Courthouse Surry, Virginia 23683 Dr. W. T. Lough Virginia State Corporation Commission Division of Energy Regulation Post Office Box 1197 Richmond, Virginia 23209 Regional Administrator, Region II U.S. Nuclear Regulatory Commission 101 Marietta Street N.W., Suite 2900 Atlanta, Georgia 30323 Robert B. Strobe, M.D., M.P.H.
State Health Commissioner Office of the Commissioner Virginia Department of Health P.O. Box 2448 Richmond, Virginia 23218 Surry Power Station Units 1 and 2 Office of the Attorney General Commonwealth of Virginia 900 East Main Street Richmond, Virginia 23219 Mr. M. L. Bowling, Manager Nuclear Licensing & Programs Virginia Electric and Power Company Innsbrook Technical Center 5000 Dominion Blvd.
Glen Allen, Virginia 23060