VIRGINIA ELECTRIC AND POWER COMPAN~

RICHMOND, VIRGINIA 23261 October 12, 1995 United States Nuclear Regulatory Commission Attention: Document Control Desk VVashington, D. C. 20555 Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNIT 1 STEAM GENERATOR TUBE INSPECTION REPORT Serial No.95-512 NURPC Docket No.

50-280 License No. DPR-32 Planned inservice inspection of the Surry Unit 1 "C" steam generator was completed during the 1995 refueling outage. In accordance with Surry Power Station Technical Specifications, Section 4.19.F.a, this letter provides notification of the steam generator tube that was plugged during the outage. One tube (R38-C74) was plugged as a precautionary measure due to a concern with anti-vibration bar wear.

"C" STEAM GENERATOR TUBE PLUGGED BOW COLUMN 38 7 4 (precautionary)

If you have any questions concerning these results, please contact us.

Very truly yours,

~CA/p~

James P. O'Hanlon Senior Vice President - Nuclear cc:

United States Nuclear Regulatory Commission Region II 101 Marietta Street, N. W.

Suite 2900 Atlanta, Georgia 30323 Mr. M. W. Branch NRC Senior Resident Inspector Surry Power Station