i l l,I' VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 March 1, 1996 United States Nuclear Regulatory Commission Attention: Document Control Desk Washington, D.C. 20555 Gentlemen:
VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNITS 1 AND 2 Serial No.96-028 NURPC Docket Nos. 50-280 50-281 License Nos. DPR-32 DPR-37 1995 ANNUAL STEAM GENERATOR INSERVICE INSPECTION REPORT In accordance with the requirements of Technical Specification 4.19.F.b, Virginia Electric and Power Company submits the 1995 Steam Generator lnservice Inspection Report for Surry Power Station Units 1 and 2.
During the September 1995 refueling outage for Surry Power Station Unit 1, the tubes in the "C" steam generator were examined. The information in Attachment 1 is a summary of the results of those examinations. These results include the number and extent of the tubes examined, location and characterization of each indication of an imperfection, and identification of the tubes that were plugged. Attachments 2 and 4 include tubesheet maps indicating plugged tubes, hot leg bobbin indications, cold leg bobbin indications, and rotating pancake coil test locations for Surry Power Station Units 1 and 2, respectively. During the February 1995 refueling outage for Surry Power Station Unit 2, the tubes in the "A" steam generator were examined. contains a summary of the results of those examinations. Attachment 5 provides a glossary of the terms used in the report.
Should you require additional information, please contact us.
Very truly yours, M. L. Bowling, Manager Nuclear Licensing and Operations Support Attachments
- 1. 1995 Annual Steam Generator lnservice Inspection Report for Surry Unit 1.
- 2. Surry Unit 1 Tubesheet Maps.
- 3. 1995 Annual Steam Generator lnservice Inspection Report for Surry Unit 2.
- 4. Surry Unit 2 Tubesheet Maps.
- 5. Glossary of Terms.
- 9603110250 960301
~
4of 1'/(
. PDR ADOCf.<. 05000280 G
\\.
I I cc:
U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, N.W.
Suite 2900 Atlanta, Georgia 30323 Mr. M. W. Branch NRG Senior Resident Inspector Surry Power Station