e e

VIRGINIA ELECTRIC AND PowER COMPANY RICHMOND, VIRGINIA 23261 October 6, 1997*

United States Nuclear Regulatory Commission

  • r.Attention: Document Control Desk

" Washington, D.C. 20555

_Gentlemen:

  • VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNIT 1 Serial No.

NL&OS/GDM Docket No.

License No.

ASME SECTION XI INSERVICE INSPECTION PROGRAM REVISION 97-566 RO 50-280 DPR-32

  • Attached for your information is a revision to the Surry Power Station Unit 1, Interval 3, ASlv1E Section XI lnservice Inspection Program and Inspection Plan. The revision is

_ administrative in nature and incorp.orates a status update of each individual relief request. Attachment 1 provides a change summary and Revision 1 of the lnservice Inspection Program, and AttacMment. -2 prov1des a change summary and Bevision 8 of the lnservice Inspection Plan. -

If you have any questions concerning this request, please contact us.

Very truly yours, R. F. Saunders Vice President - Nuclear Engineering and Services -

Attachment Commitments made in this letter: None I IIIIII II/II IIIII I/Ill llll/ 1111111111111,

  • "fl1:1saec.

cc:

U. S. Nuclear Regulatory Commission Region II Atlanta Federal Center 61 Forsyth St., SW, Suite 23T85 Atlanta, Georgia 30303 Mr. R. A. Musser NRC Senior Resident Inspector Surry Power Station

ATTACHMENT 1

SUMMARY

OF CHANGES AND ASME SECTION XI INSERVICE INSPECTION PROGRAM, REV 1 SURRY POWER STATION UNIT 1

Summary of Changes To Surry Unit 1 ISi Program Since Original Submittal 1.

Added the following relief requests:

IWE-1 SR-009 through SR-018 RR-010 through RR-012 SH-2

2.

Withdrew the following relief request:

RR-001

3.

Added and withdrew the following relief requests:

RR-004 and RR-009

4.

Revised the following relief request:

RR-010

5.

Added the following Code Cases:

N-41 6-1, N-489, N-491, N-522, N-524 and N-535