VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 March 27, 1998 United States Nuclear Regulatory Commission Attention: Document Control Desk Washington, D. C. 20555 Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNIT 1 ASME SECTION XI RELIEF REQUEST REQUEST FOR ADDITIONAL INFORMATION Serial No.

NL&OS/GDM Docket No.

License No.

98-177A R2 50-280 DPR-32 In a March 23, 1998, telephone call with the NRC, Virginia Electric and Power Cpmpany (Virginia Power) requested relief from ASME Section XI pressure boundary corrective action and flaw evaluation requirements to permit a determination of operability of the Residual Heat Removal System. The NRC subsequently provided verbal approval of the relief request. The request was formally documented in a letter (Serial No.98-177) also dated March 23, 1998.

In a subsequent telephone call between Virginia Power and the NRC on March 25, 1998, the NRC requested two additional actions regarding the relief request.

Therefore, we commit to complete the following two actions:

1. Virginia Power will perform a failure analysis of the Residual Heat Removal System pipe leak, including metallurgical analysis of a pipe sample taken from the leak area.
2. Upon completion of the analysis, we will provide the results to the NRC.

If you have any further questions or require additional information, please contact us.

Very truly yours, R. F. Saunders Vice President - Nuclear Engineering and Services Commitments made in this letter: As itemized above.

-~-~-~-~

9804-070403 980327 PDR ADOCK 05000280 P

PDR

cc:

United States Nuclear Regulatory Commission Region II Atlanta Federal Center 61 Forsyth Street, SW, Suite 23T85 Atlanta, Georgia 30303 Mr. R. A. Musser NRC Senior Resident Inspector Surry Power Station