ML18153A257

From kanterella
Jump to navigation Jump to search
Forwards LER 98-009-00,reviewed by Station Nuclear Safety & Operating Committee.Commitments,Listed
Date released: 12/10/2018 Download: ML18153A257


LER 98-009-00:on 980509,nonisolable Leak of Reactor Coolant Pump Seal Injection Line Weld,Was Discovered.Caused by Lack of Fusion or Thermal Fatigue Coupled W/Vibration Stress Due to Loose Rod Hanger.Rcp Seal Injection Line Removed
ML18153A258
Person / Time
Site: Surry Dominion icon.png
Issue date: 06/03/1998
From: Christian D
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
References
Download: ML18153A258 (3)
Forwards LER 98-009-00,reviewed by Station Nuclear Safety & Operating Committee.Commitments,Listed
ML18153A256
Person / Time
Site: Surry Dominion icon.png
Issue date: 06/03/1998
From: Christian D
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
Download: ML18153A256 (2)