e VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 February 4, 1999 United States Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001 Gentlemen:
VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNIT 1 INSERVICE INSPECTION
SUMMARY
REPORT FOR THE 1998 REFUELING OUTAGE Serial No.:
99-038 NLOS/MM Docket No.:
50-280 License No.: DPR-32 As set forth in the provisions of ASME Section XI, Paragraph IWA-6230, enclosed is the lnservice Inspection Summary Report for Surry Power Station Unit 1 for the 1998 refueling outage.
This report provides a summary of the examinations performed during the outage for the third inservice inspection interval.
In accordance with IWA-6220 of ASME Section XI, Attachment 1 includes a Form NIS-1, "Owner's Report for lnservice Inspection~," an examination summary, and abstracts of examinations performed. Attachment 2 includes Forms NIS-2, "Owner's Report for Repairs or Replacements."
The entire report will be maintained on file at the corporate office. If you have any questions or require additional information, please contact us.
Very truly yours, c::>\\~ffv L. N. Hartz Vice President - Nuclear Engineering and Services Attachments Commitment:
- ifu~9-submit relief requests for those examinations not achieving the required volume or surface coverage as specified by ASME Section XI and clarified by Code Case N-460.
- 9902180296 990204 _____ \\
PDR ADOCK 05000280 1
G PDR
~-
- r.
cc:
U.S. Nuclear Regulatory Commission Region II Atlanta Federal Center 61 Forsyth St., SW, Suite 23 T85 Atlanta, GA 30303-3415 Mr. R. A. Musser NRG Senior Resident Inspector Surry Power Station