.... _ -

.e-e VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 W. L. STEWART VICE PRESIDENT NUCLEAR OPERATIONS December 23, 1987 United States Nuclear Regulatory Commission Attention:

Document Control Desk Washington, D. C.

20555 Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNITS 1 AND 2 WITHDRAWAL OF TECHNICAL SPECIFICATION CHANGE REQUEST FOR CONTAINMENT TYPE A TESTING 87-375A Serial No.

NO/ETS:vlh Docket Nos.

50-280 50-281 License Nos. DPR-32 DPR-37 In letter No.87-375 dated July 23,

1987, we submitted a Technical Specification change request pertaining to Containment Integrated Leak Rate Testing.

Based on unresolved technical issues i dent i fi ed in combined NRC Inspection Report 50-280 and 50-281/86-36 dealing with containment testing, we are withdrawing this Technical Speci fi cation change request and associated exemption request until these technical issues can be evaluated and resolved.

We intend to provide NRC Region II an evaluation of the issues identified in IR 50-280 and 50-281/86-36 by January 29, 1988.

Following resolution of these issues, we intend to resubmit another Technical Specification change request on Containment Integrated Leak Rate Testing.

Should you have any questions, please contact us.

Very truly yours, v!lrw:f-i/adw,Ck /ui cc:

U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, N. W.

Suite 2900 Atlanta, GA 30323 Mr. W. E. Holland NRC Senior Resident Inspector Surry Power Station

,,- '880:l.05-0298--871223 PDR ADOCK 05000280 p

_ DCD