RC-18-0060, (VCSNS) - Request to Revise Technical Specifications to Correct Administrative Error

From kanterella
(Redirected from ML18150A684)
Jump to navigation Jump to search

(VCSNS) - Request to Revise Technical Specifications to Correct Administrative Error
ML18150A684
Person / Time
Site: Summer 
(NPF-012)
Issue date: 05/30/2018
From: Lippard G
South Carolina Electric & Gas Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
RC-18-0060, TAC ME5899
Download: ML18150A684 (8)


Text

George A. Lippard Vice President; Nuclear Operations 803.345.4810 A SCANA COMPANY May 30, 2018 RC-18-0060 Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555

Dear Sir / Madam:

Subject:

VIRGIL C. SUMMER NUCLEAR STATION (VCSNS)

DOCKET NO. 50-395 OPERATING LICENSE NO. NPF-12 REQUEST TO REVISE TECHNICAL SPECIFICATIONS TO CORRECT ADMINISTRATIVE ERROR

References:

1. Letter from S. Williams, NRC, to T. D. Gatlin, Virgil C. Summer Nuclear Station (VCSNS), Unit 1, "Issuance Of Amendment Regarding Transition To A Risk-Informed, Performance-Based Fire Protection Program In Accordance With 10 CFR 50.48(c)"

(TAC NO. ME7586) dated February 11, 2015 (ML14287A289)

2. Proposed Guidance for Correction of Technical Specification Typographical Errors, SECY-96-238, dated November 19, 1996 (ADAMS Legacy Library Accession No. 9611250030)
3. Letter from R.E. Martin, NRC, to T. D. Gatlin, Virgil C. Summer Nuclear Station (VCSNS), Unit 1, "Issuance Of Amendment Relocating Administrative Controls Related To Quality Assurance (TAC NO. ME5899) dated March 20, 2012 (ML11346A006)
4. Letter from T.D. Gatlin, Virgil C. Summer Nuclear Station (VCSNS) Unit 1 Docket No.

50-395 Operating License No. NPF-12 License Amendment Request - LAR 10-03108, "Proposed Change To Relocate Administrative Control Requirements Related To Quality Assurance And Submittal Of Quality Assurance Program Description (QAPD)", dated March 18, 2011 (ML110810688)

5. Letter from T.D. Gatlin, Virgil C. Summer Nuclear Station (VCSNS) Unit 1 Docket No.

50-395 Operating License No. NPF-12 License Amendment Request - LAR-06-00055, "License Amendment Request to Adopt NFPA 805 Performance-Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants (2001 EDITION)",

dated November 15, 2011 (ML11332A078)

This letter requests Nuclear Regulatory Commission's (NRC) approval of a correction to an error in Virgil C. Summer Nuclear Plant (VCSNS) Technical Specifications (TS). This error was inadvertently introduced during issuance of License Amendment 199 (Reference 1). This was neither addressed in the notice to the public nor reviewed by the NRC, and thus falls within the scope of guidance provided in SECY-96-238 (Reference 2).

V. C. Summer Nuclear Station

  • P. 0. Box 88
  • 29065
  • F (803) 941-9776
  • www.sceg.com

Document Control Desk CR-16-01992 RC-18-0060 Page 2 of 2 describes the error and corrections. Enclosure 2 provides a mark-up of the TS page as issued by License Amendment 199. Enclosure 3 provides a clean copy of the TS page.

This letter does not contain any new regulatory commitments.

If there are any questions or if additional information is needed, please contact Michael S.

Moore at (803) 345-4752.

NRK/GAL/bb : Description of Technical Specification Error : Mark-Up Technical Specification Page : Clean Copy of Technical Specification Page cc:

S. A. Williams NSRC RTS (CR-16-01992)

File (813.20)

PRSF (RC-18-0060)

Very Truly Yours,

Document Control Desk CR-16-01992 RC-18-0060 Page 1 of 2 VIRGIL C. SUMMER NUCLEAR STATION (VCSNS)

DOCKET NO. 50-395 OPERATING LICENSE NO. NPF-12 ENCLOSURE 1 Description of Technical Specification Error A. Requested Action Consistent with the information contained in SECY-96-238, Proposed Guidance for Correction of Technical Specification Typographical Errors, South Carolina Electric and Gas (SCE&G), the licensee for Virgil C. Summer Nuclear Station (VCSNS), is requesting correction for an error that was introduced into the VCSNS Technical Specifications (TS) in License Amendment 199 (Reference 1).

B. Typographical Error TS Section 6.8.2 was deleted in License Amendment 188 (Reference 3) and inadvertently re-inserted into the TS in Amendment 199. The request to delete section 6.8.2 on TS page 6-11 was included in LAR-10-03108 (Reference 4) and approved by the NRC in License Amendment 188.

While LAR-10-03108 was still undergoing NRC review, the station submitted LAR 00055 (Reference 5) with section 6.8.2 on TS page 6-11 not deleted. This change page was included in License Amendment 199.

Amendment 199 was approved after Amendment 188 which caused section 6.8.2 on TS page 6-11 to be re-inserted. VCSNS is requesting that TS page 6-11 from License Amendment 199 be reissued with TS Section 6.8.2 deleted as approved in License Amendment 188.

C. Corrections to the Affected TS Page SECY 96-238, (Reference 2) provides guidance to correct inadvertent typographical errors intheTS pages. Specifically:

"...if the licensee can demonstrate that the error was introduced inadvertently in a particular license amendment and that the erroneous change was not addressed in the notice to the public nor reviewed by the staff. Under these limited circumstances, the change that introduced the typographical error was not a proper amendment to the

Document Control Desk CR-16-01992 RC-18-0060 Page 2 of 2 license because it was neither addressed in the notice nor reviewed, and correction of the typographical error is not a "change" to the TS. Accordingly, the typographical error may be corrected by a letter to the licensee from the NRC staff, instead of an amendment to the license...."

The above errors were not noticed to the public, nor reviewed by the NRC as part of the application amendment process. Therefore, these errors may be corrected without a license amendment.

Document Control Desk CR-16-01992 RC-18-0060 Page 1 of 2 VIRGIL C. SUMMER NUCLEAR STATION (VCSNS)

DOCKET NO. 50-395 OPERATING LICENSE NO. NPF-12 ENCLOSURE 2 Mark-up Technical Specification Page

ADMINISTRATIVE CONTROLS

d.

Critical operation of the unit shall not be resumed until authorized by the Commission.

6.8 PROCEDURES AND PROGRAMS 6.8.1 Written procedures shall be established, implemented and maintained covering the activities referenced below:

a.

The applicable procedures recommended in Appendix "A" of Regulatory Guide 1.33, Revision 2, February 1978.

b.

Refueling operations.

c.

Surveillance and test activities of safety-related equipment.

d.

Security Plan.

e.

Emergency Plan.

f.

PROCESS CONTROL PROGRAM.

g.

OFFSITE DOSE CALCULATION MANUAL.

h.

Effluent and environmental monitoring program using the guidance in Regulatory Guide 4.15, Revision 1, February 1979.

6.8.2 Each procedure of 6.8.1 above, and changes thereto, shall bo reviewed prior to implementation as sot forth in 6.5 above. <

6.8.3 NOT USED.

Deleted 6.8.4 The following programs shall be established, implemented and maintained:

a.

Primary Coolant Sources Outside Containment A program to reduce leakage from those portions of systems outside containment that could contain highly radioactive fluids during a serious transient or accident to as low as practical levels. The systems include the chemical and volume control, letdown, safety injection, residual heat removal, nuclear sampling, liquid radwaste handling, gas radwaste handling and reactor building spray system. The program shall include the following:

1)

Preventive maintenance and periodic visual inspection requirements, and

2)

Integrated leak test requirements for each system at refueling cycle intervals or less.

p

b.

In-Plant Radiation Monitoring

1)

Training of personnel,

2)

Procedures for monitoring, and

3)

Provisions for maintenance of sampling and analysis equipment.

SUMMER-UNIT 1 6-11 Amendment No. 199

Document Control Desk CR-16-01992 RC-18-0060 Page 1 of 2 VIRGIL C. SUMMER NUCLEAR STATION (VCSNS)

DOCKET NO. 50-395 OPERATING LICENSE NO. NPF-12 ENCLOSURE 3 Clean Copy of Technical Specification Page

ADMINISTRATIVE CONTROLS

d.

Critical operation of the unit shall not be resumed until authorized by the Commission.

6.8 PROCEDURES AND PROGRAMS 6.8.1 Written procedures shall be established, implemented and maintained covering the activities referenced below:

a.

The applicable procedures recommended in Appendix "A" of Regulatory Guide 1.33, Revision 2, February 1978.

b.

Refueling operations.

c.

Surveillance and test activities of safety-related equipment.

d.

Security Plan,

e.

Emergency Plan.

f.

PROCESS CONTROL PROGRAM.

g.

OFFSITE DOSE CALCULATION MANUAL.

h.

Effluent and environmental monitoring program using the guidance in Regulatory Guide 4.15, Revision 1, February 1979.

6.8.2 DELETED 6.8.3 NOT USED.

6.8.4 The following programs shall be established, implemented and maintained:

a.

Primary Coolant Sources Outside Containment A program to reduce leakage from those portions of systems outside containment that could contain highly radioactive fluids during a serious transient or accident to as low as practical levels. The systems include the chemical and volume control, letdown, safety injection, residual heat removal, nuclear sampling, liquid radwaste handling, gas radwaste handling and reactor building spray system. The program shall include the following:

1)

Preventive maintenance and periodic visual inspection requirements, and

2)

Integrated leak test requirements for each system at refueling cycle intervals or less.

b.

In-Plant Radiation Monitoring

1)

Training of personnel,

2)

Procedures for monitoring, and

3)

Provisions for maintenance of sampling and analysis equipment.

SUMMER-UNIT 1 6-11 Amendment No. 18, 49, 72, 79, 117, 130, 188, 199