PUBLIC MEETING ANNOUNCEMENT
Title:
NuScale Design Certification Review Discussions June 13, 2018, 01:00 PM to 03:00 PM Date(s) and Time(s):
Location:
Teleconference Category:
This is a Category 1 meeting. The public is invited to observe this meeting and will have one or more opportunities to communicate with the NRC after the business portion of the meeting but before the meeting is adjourned.
Purpose:
Public meeting to Discuss Section 3.6.2 "Determination of Rupture Locations and Dynamic Effects Associated with the Postulated Rupture of Piping" of the NuScale DC application.
Topics to discuss Brief discussion of the NuScales overall pipe break analysis approach including a summary of the identified high-energy pipe break locations for NuScale plant Discussion of NuScales approach/methodology to address the potential non-conservatism of the ANS 58.2 Standard jet modeling as described in RAI 8836 (ML17153A065), Question 03.06.02-5 including details of the NuScales plant specific CFD modeling for assessing jet impingement and blast wave effect V and V of the CFD Progress made including applicable CFD preliminary results Schedule confirmation (8-24-18) for submitting RAI response including applicable FSAR markups and associated technical report
Contact:
Gregory Cranston 301-415-0546 Gregory.Cranston@nrc.gov NRC Office of New Reactors
Participants:
External NuScale Power LLC Teleconference:
Bridge Number Pass Code (877) 950-1785 4312028 Docket No:
05200048 Comments:
Email a meeting Contact for the Conference Call information.
PUBLIC MEETING AGENDA
NuScale Design Certification Review Discussions June 13, 2018, 01:00 PM to 03:00 PM Teleconference
The time of the meeting is local to the jurisdiction where the meeting is being held.
The NRC provides reasonable accommodation to individuals with disabilities where appropriate. If reasonable accommodation is needed to participate in this meeting, or if a meeting notice, transcript, or other information from this meeting is needed in another format (e.g., Braille, large print), please notify the NRC meeting contact.
Determinations on requests for reasonable accommodation will be made on a case-by-case basis.
ADAMS Accession Number: ML18150A415 OFFICIAL RECORD COPY https://www.nrc.gov/pmns/mtg?do=details&Code=20180650 Link to meeting details:
Commission's Policy Statement on "Enhancing Public Participation in NRC Meetings" 67 Federal Register 36920, May 28, 2002 The policy statement may be found on the NRC website http://www.nrc.gov/reading-rm/doc-collections/commission/policy/67fr36920.html