Requests Relief from 1980 ASME Code Section XI Requirements Re HX Replacement.Util Proposes to Purchase Replacement HXs from Vendor W/Qa Program Per 10CFR50,App B.Summaries of Comparisons Performed Encl.Fee Paid
ML18150A257
Person / Time
Site: Surry  
Issue date: 07/23/1987
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
87-341, NUDOCS 8707300025
Download: ML18150A257 (20)


Text

e VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 10 CFR 50.55a W. L. STEWART VxcE PRESXDENT NUCLEAR 0PERA.TXONS July 23, 1987 U. S. Nuclear Regulatory Commission Attn:

Document Control Desk Washington, D. C.

20555 Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNITS l AND 2 ASME SECTION XI RELIEF REQUEST HEAT EXCHANGER REPLACEMENTS Serial No.87-341 E&C/MWH:vlhrl Docket Nos.

50-280 50-281 License Nos. DPR-32 DPR-37 Surry Power Station is planning to replace the component cooling water heat exchangers and is studying the replacement of the recirculation spray heat exchangers.

Pursuant to 10 CFR 50.55a paragraph g(5), relief is requested from certain requirements for component replacement as delineated in the ASME Code Section XI, 1980 Edition, Winter 1980 Addenda.

The following basis is provided.

The original heat exchangers were manufactured to the requirements of the 1968

.ASME Code Section III, Class C.

In accordance with IWA-7210, Construction Codes, the replacement must meet the requirements of the original construction code, or alternatively, later editions of the same construction code.

Because the original construction code, 1968 ASME Code Section III, Class C, referred to Section VIII of the ASME

Code, we request permission to use the 1986 Edition of Section VIII of the ASME Code for the construction of these replacement heat exchangers.

To facilitate the NRC's review of this relief request, we have performed a evaluation of the requirements of the 1968 ASME Code Section III, Class C with respect to the requirements of the 1986 ASME Code Section VIII, Division 1.

In addition, we have compared Subsection UG (General) and Subsection UW (Fabrication) requirements of the 1968 Edition to the 1986 Edition of the ASME Code Section VIII, Division 1.

Summaries of the comparisons performed are provided in Attachments A thru C.

-- --- ------~------ -,

,'-8707300025 870723 PDR ADOCK 05000280

e Our evaluation of these Code comparisons has concluded that a vessel built to the 1986 ASME Code Section VIII, Division 1 will meet or exceed the original requirements of the 1968 ASME Code Section III, Class C.

Therefore, Virginia Electric and Power Company proposes to purchase these replacement heat exchangers to the requirements of the 1986 ASME Code Section VIII, Division 1 and from a vendor which has a quality assurance program in accordance with 10 CFR 50, Appendix B.

We consider that adequate justification exists for relief to be granted from the 1980 ASME Code Section XI requirement.

Your prompt attention is requested so that timely heat exchanger replacement can be accomplished.

Should you require additional information, please contact us.

In accordance with 10 CFR 170, an application fee of $150.00 is enclosed.

Very truly yours,

't)~~

w. {:~~

Attachments cc:

U. S. Nuclear Regulatory Commission Region II 101 Marietta Street, N. W.

Suite 2900 Atlanta, Georgia 30323 Mr. W. E. Holland NRC Senior Resident Inspector Surry Power Station Mr. Chandu P. Patel NRC Project Manager - Surry Directorate II-2 Division of Reactor Projects I/II

e APPENDIX A EVALUATION OF REQUIREMENTS FOR VESSELS BUILT TO 1968 ASME CODE SECTION III, CLASS C WITH RESPECT TO REPLACEMENT VESSELS BUILT TO 1986 ASME CODE SECTION VIII, DIVISION 1

N-2110 N-2111 N-2112 N-2113 EVALUATION OF REQUIREMENTS 1968 ASME CODE SECTION III, CLASS C ASME SECTION III, 1968 EDITION SUBSECTION C, REQUIREMENTS FOR CLASS C VESSELS ARTICLE 21, GENERAL REQUIREMENTS REQUIREMENTS Subsection C covers requirements for vessels classified as Class C.

The requirements of Section VIII of the Code shall apply to the materials, design, fabrication, inspection and testing and certification of Class C vessels except that the below listed additional requirements apply.

Paragraph U-l(g) of Section VIII shall not apply to Class C vessels.

The rules of paragraph UW-2(a) of Section VIII of the Code shall apply to any Class C vessels that may contain substances whose level of radioactivity is such that their production, storage, or use is subject to regulations of Federal or Local jurisdictions.

EVALUATION OF REQUIREMENTS The original design specifications required the recirculation spray and the component cooling water heat exchangers to be built to ASME Section III, Class C.

The new recirculation spray heat exchangers and the new component cooling water heat exchangers are con-sidered replacements per ASME Section XI, Article IWA-7000.

Article IWA-7000 allows replacement vessels ~

to be built to a later edition of the construction

,ail' code.

The construction code used to manufacture the original heat exchangers was 1968 ASME Section III, Class C which referred to Section VIII.

The require-ments of ASME Section XI, IWA-7000 are met since the replacement vessels are to be built to 1986 ASME Section VIII requirements.

In addition, a Quality Assurance Program in accordance with 10 CFR 50 Appendix B shall be required of the vessel manufacturer.

Paragraph U-l(g) is a permissive statement in the 1968 Section VIII requirements referring to stamping of the vessel.

The 1986 Edition of Section VIII contains essentially the same statement only the paragraph is (k) rather than (g).

We intend to have these replacement heat exchangers built in accordance with thillllll..

requirements of the 1986 ASME Code Section VIII and

~

they will be stamped with the Code "U" symbol.

Paragraph UW-2(a) of the 1986 ASME Section VIII describes welding and radiography requirements.

These requirements are the same as the 1968 ASME Section VIII but are ex-plained in more detail.

The rules of UW-2(a) will be applied to the replacement recirculation spray heat exchangers.

The rules of UW-2(a) were not applied to the original component cooling water heat exchangers because this article was specifically exempted in the original procurement specification.

The rules of UW-2(a) will not apply to the replacement component cooling water heat exchangers, but the vessels will be required to be fully radiographed.

N-2114 N-2115 EVALUATION OF REQUIREMENTS 1968 ASME CODE SECTION III, CLASS C - Cont'd ASME SECTION III, 1968 EDITION SUBSECTION C, REQUIREMENTS FOR CLASS C VESSELS ARTICLE 21, GENERAL REQUIREMENTS Paragraph UG-125 through UG-134 of Section VIII shall not apply and the requirements of Article 9 shall be substituted. Article 9 - Protection Against Overpressure.

Class C vessels shall be stamped with the letter "N" below the Code U -

symbol in the stamping shown in Fig. UG-118 of Section VIII of the Code.

Original Materials of Construction Recirculation Spray Heat Exchangers:

Shell - 90/10 CuNi Tube Sheets - 90/10 CuNi Tubes - 90/10 CuNi Component Cooling Water Heat Exchangers:

Shell - Carbon Steel Tube Sheets - Carbon Steel - 1/8" Monel Overlay Tubes - 90/10 CuNi EVALUATION OF REQUIREMENTS This requirement pertaining to pressure relief devices was exempted in the original design specification for the component cooling water heat exchangers.

Over-pressure protection is not required in either the case of the component cooling water or the recirculation spray heat exchangers, therefore, this requirement does not apply to the replacement heat exchangers.

Since the replacement heat exchangers are being fabricated to ASME Section VIII in lieu of ASME Section III, no "N" stamp is required.

Replacement Materials of Construction Recirculation Spray Heat Exchangers:

Shell - Stainless Steel Tube Sheets - Stainless Steel Clad w/Titanium Tubes - Titanium Section XI allows material changes to improve operability and reliability.

The replacement materials of construction were selected because of their superior resistance to corrosion and pitting.

Component Cooling Water Heat Exchangers:

Shell - Carbon Steel Tube Sheets - Carbon Steel Clad w/Titanium Tubes - Titanium Section XI allows material changes to improve operability and reliability.

Titanium was selected to replace Cu-Ni because of it's superior ability to resist the corrosive effects of the Surry Power Station river water.

e APPENDIX B EVALUATION OF SUBSECTION UG (GENERAL) e 1968 VS 1986 ASME CODE SECTION VIII, DIVISION 1

SUBSECTION

( 1986 TITLES)

General (Matl's)

UG-4 Plate Forgings UG-6 Castings UG-7 Pipe & Tubes UG-8 Weld Materials UG-9 Nonspec. Material UG-10 Hise. Press.

Parts UG-11 Bolts & Studs UG-12 8418-1493743-Bl COMPARISON OF 1968 TO 1986 ASHE CODE SECTION VIII DIVISION l SUBSECTION.UG (GENERAL)

Page I of 8 1968 ASHE VI II Materials subject to stress due to pressure shall conform to ASHE Section II specs.

(This subsection is UG-5 in 1986 Code.)

Plate shall conform to ASHE Section II specs'.

(This sub~

section is UG-5 in 1986 Code.)

Use of forged and rolled material allowed provided coarse ingot structure removed.

(This subsection is UG-7 in 1968 Code.)

Use of cast aaterial allowed.

(This subsection is UG-8 in 1968 Code.)

Use of seamless and welded pipe and tubes allowed.

(This subsection is UG-9 in 1968 Code.)

Does. not exist in 1968 Code.

Provides conditions for accepting materials not fully identified with a Code-approved spec.

Provides exceptions for accepting prefabricated and preformed pressure parts.

Allows use of bolts and studs.

SURRY POWER STATION 1986 ASHE VIII Same as UG-6(b) in 1968 Code.

UG-4(b) added to address nonpressure parts exemption from conforming to material specifications for material they are attached to.

Same as 1968 Code except does not include nonpressure parts which were moved to UG-4(b).

Same as 1968 Code.

Same as 1968 Code.

Same as 1968 Code except testing of tubes after finning has been expanded.

Weld materials must comply with AS.HE Section II Expanded to include material with manufacturer certification and material identified in a production lot but not certified because docu-aentation is not available.

Saae as 1968 Code and allows parts to be furnished by a manufacturer who is not a Certificate of Authorization bolder.

Expanded to include studs greater than 80 in.

in length with unthreaded portion specs.

COMMENTS 1986 Code Section UG-4(b) allows material for nonpressure part to not confrom to the material specification to which they are attached or to a material specifica-tion permitted in Division 1.

Equivalent requirements Equivalent requirements Equiva.lent requirements Equivalent requirements.

1968 Code allows internal pneumatic or individual tube hydraulic testing of each tube after finning.

1986 Code more restrictive since 1968 Code did not specify any requirements.

1986 Code provides conditions for identi-fied aaterial with complete certification from the material manufacturer and material identified to a particular production lot but which cannot be qualified under UG-lO(a).

1986 and 1968 Codes equivalent.

1986 Code allows parts be furnished by a manufacturer who is not a Certificate of Authorization holder.

NA - Do not anticipate using stud >80 in.

in length.

SUBSECTION (1986 TITLES)

Nuts & Washers UG-13 Rods & Bars UG-14 Product Spec.

UG-15 General (Design)

UG-16 Methods of Fab.

UG-17 Matl's in Coiab.

UG-18 Design Temp.

UG-20 Design Press.

UG-21 Loadings UG-22 l'tax. Allow.

Stress UG-23 8418-1493743-Bl COMPARISON OF 1968 TO 1986 ASHE CODE SECTION VIII DIVISION 1 SUBSECTION UG (GENERAL)

Page 2 of 8 1968 ASHE VII I Allows use of nuts and washers.

Allows use of rod and bar stock for pressure parts.

Does *not exist in 1968 Code.

SURRY POWER STATION 1986 ASHE VIII Same as 1968 Code.

Same as 1968 Code.

Allows use of wrought iron products for which no spec. exists for a particular grade under certain conditions.

Specifies minimum thickness for plate Expanded to be more specific and excludes corrosion allowance in allowable thickness.

Allows construction by combination of Same as 1968 Code.

iaethods.

Allows coabination of materials.

Saiae as 1968 Code.

Guidelines fo_r detenaining design teaperature.

Guidelines for determining design pressure.

Loads to be considered during*

design.

Guidelines for calculating maximum allowable stress values.

Expanded to include external pressure con-struction.

Same as 1968 Code.

Expanded t~ include attachment of internals and differential ~hermal expansion.

Expanded to include earthquake and wind loading.

COHHENTS Equivalent requirements Equivalent requirements NA - Since wrought iron products are not being used.

1986 Code more restrictive since 1968 Code allowed corrosion allowance as part of 111in. wall.

Equivalent requirements Equivalent requirements 1986 Codes more restrictive.

Includes section for design temperature limits for exterior pressure construction and maximum design temperature of materials_.

Equivalent requirements 1986 Code more restrictive.

1986 Code includes the attachment of internals and differential' thermal expansion in loadings to be considered in the design of a vessel.

1986 Code more restrictive.

1986 Code Section UG-23(d) provides criteria for the combination of earthquake loading or wind loading with other loadings in UG-22.

e e

SUBSECTION

( 1986 TITLES)

Corrosion UG-25 Linings UG-26 Shell Thickness Internal Press.

UG-27 Shell Thickness Under External Press.

UG-28 Stiffening Rings UG-29 Attach. Stiff Rings UG-30 Tubes UG-31 Flat Heads UG-34 8418-1493743-BI COMPARISON OF 1968 TO 1986 ASKE CODE SECTION VIII DIVISION l SUBSECTION UG (GENERAL)

Page 3 of 8 1968 ASHE VIII Guidelines for corrosion allowance.

Linings not considered in wall strength.

Guidelines for calculating minim1111 shell thickness required.

Guidelines for calculating ainiaum shell thicknes.s required.

Guidelines for moment of inertia for stiffening rings.

Guidelines for attaching stiffening rings to shell.

NA Guidelines for determining ainimum tube wall thickness.

Guidelines for determining minimum thickness of flat heads.

SURRY POWER STATION 1!186 ASHE VIII Same as 1968 Code plus requires user to specify corrosion allowance other than those required by UG-25.

Same as 1968 Code.

Same an 1968 Code plus refers to UW-9 for reduction in thickness within a shell course or spherical shell..

Revised to use different equations; same basic content.

Revised to use new equations and figures for determining arc of shell left unsupported; saae basic content.

Revised to delete riveting and bolting as means of attaching stiffening rings; only welding and brazing now allowed.

Revised to use Section UG-28 for pipe under external pressure instead of Figure UG-31 in 1968 Code.

Same as 1968 Code; minor changes in equations.

COMMENTS 1986 Code more restrictive.

Requires user to specify corrosion allowance other than those required by UG-25.

Equivalent requirements 1986 Code more restrictive.

Re~uires any reduction.in thickness within a shell course or spherical shell to be in accord-ance with UW-9.

1986 Code is more restrictive.

Both shells and tubes under external pressure are included.

Different equations are used in the 1986 Code for the determination of required minimum thickness for cylindrical and spherical shells.

1986 Code more restrictive.

Equations are provided to determine required moment of intertia in cases where only stiffening ring is considered or combined ring shell is considered.

1986 Code more restrictive.

1986 Code only allows welding and brazing to be used for attaching stiffening rings to shell.

Equivalent requirements.

1986 Code requires Section UG-28 be used for pipe under external pressure instead of Figure UG-31.

Equivalent requirements.

1986 Code has minor changes in equations.

e e

SUBSECTION (1986 TITLES)

Openings UG-36 Opening Reinf.

UG-37 Reinf. Limits UG-40 Reinf. Strength UG-41 Attach. Nozzles UG-43 Flanges &

Pipe Fitting UG-44 Nozzle Neck Thickness UG-54 Supports UG-54 8418-1493743-BI COMPARISON OF 1968 TO 1986 ASHE CODE SECTION VIII DIVISION 1 SUBSECTION UG (GENERAL)

Page 4 of 8 1968 ASHE VIII Guidelines for size and shape of openings in vessels.

Guidelines for deteraining required opening reinforcement.

Limits of reinforcement area.

Required strength of reinforcements for openings.

Methods of attaching pipe and nozzle necks to vessels.

Dimensional requirements of bolted flange connections.

Guidelines for wall thickness of nozzle necks.

Refers to Appendix G for support design.

SURRY POWER STATION 1986 ASHE VIII Revised to add reducers under external pressure and oblique, conical sh*e 11 sections.

Revised to provide more detail.

Added Figure UG-37-1; basically same content.

Revised to use calculations from UG-37.

Added Figure UG-40 for clarification of reinforcement dimensions.

Revised to add Figure UG-41.1 for clarification of weld strength paths.

Revised to delete riveted connections and added guidelines for stud thread engagement which are addressed in UG-44 in 1968 Code.

Revised to refer to ANSI Standards.

Revised to account for external pressure situations.

Same as 1968 Code.

COHHENTS 1986 Code more restrictive.

Includes reducer sections under internal pressure and oblique conical shell sections under internal pressure.

1986 Code has additional Figure UG-37-1, "Nomenclature and formulars for reinforced openings."

This figure illustrates a common nozzle showing symbols and formulas for determining reinforcement requirements.

1986 Code has additional Figure UG-40 which provides representative configura-tions describing the thickness or height of reinformcing element.

UG-37 calcula-tions are used to determine the maximum area in nozzle wall for reinforcement.

1986 Code has added Figure UG-41.1.

Nozzle attachment weld loads and weld strength paths to be considered.

1986 Code does not allow riveted connec-tions.

It includes formula to determine minimum stud thread engagement.

1986 Code more restrictive.

Instituted ANSI standards.

1986 Code more restrictive.

Has added requirements for vessels under external pressure.

Nozzle neck thickness must now be required_ for internal and/or external pressure.

Equivalent requirements e

SUBSECTION (1986 TITLES)

Lug Attach.

UG-55 General (Fabric)

UG-75 Cutting Plates UG-76 Mat'l Ident.

UG-77 Repair of Defects in Matl 's UG-78 Forming Shell Sect.

UG-79 Permissible Out-of-Roundness UG-80 Lug Attach.

UG-82 Charpy Tests UG-84 Heat Treatment UG-85 General (Inspec.

& Test)

UG-90 8418-1493743-Bl 1968 ASHE VIII COMPARISON OF 1968 TO 1986 ASHE CODE SECTION VIII DIVISION l SUBSECTION UG (GENERAL)

SURRY POWER STATION 1986 ASHE VIII Page 5 of 8 COl1HENTS Methods for attaching platforms, etc.

Revised to delete riveting as a method of attachment.

1986 Code more restrictive.

Riveting is

~

deleted as method of attachment of lugs or Introductory paragraph Allowable aethods of cutting aaterials.

Methods of aarking aaterials used for fabrication.

Allows repair of minor defects in aaterial.

Describes rolling of plates to avoid flat parts.

Same as 1968 Code.

Same as 1968 Code.

Same as 1968 Code.

Same as 1968 Code.

Same as 1968 Code.

Guidelines for deteraining per111is-Revised to add more detail to external sible out-of-roundness of cylindrical pressure example; same basic content.

shells.

Requirement for lugs and attachaents to conform to shell curvature.

Specifies impact testing on all aaterial subject to pressure stress.

Addresses heat treating and marking when heat treating is not performed by the *ill.

General requirements for testing and inspection.

Revised to include situation where lugs and attachments cover pressure-retaining welds.

Completely revised to specify Charpy impact tests; general revision to latest testing techniques.

Same as 1968 Code.

Revised to define more clearly responsi-bilities and documentation required of the manufacturer and inspector.

clips to the outside or inside of the vessel.

Equivalent requirements Equivalent requirements Equivalent requirements Equivalent requirements Equivalent requirements 1986 Code external pressure section in-cludes a paragraph for maximum permissible deviation fro* nom1nal plate thickness.

1986 Code provides details for the attach-ment of pressure and nonpressure parts over pressure-retaining welds.

1986 Code more restrictive.

Imposes Charpy V notch impact tests specifically.

Equivalent requirements 1986 Code more restrictive.

It is more detailed in respect to required tests, inspections, and supporting docwnenlation.

e

COMPARISON OF 1968 TO 1986 ASHE CODE SECTION VIII DIVISION 1 SUBSECTION UG (GENERAL)

Page 6 ot 8 SUBSECTION (1986 TITLES)

Inspector UG-91 Inspec. Access UG-92 Insp. of Hall's UG-93 Harking tfatl's UG-94 Exam. during Fab.

UG-95 Dimeo. Checks UG-96 Insp. during Fab.

UG-97 1968 ASHE VIII Defines qualifications of Inspectors.

Addresses inspector access to manu-facturer's shop.

Specifies documentation review and inspections to be perforaed by Inspectors.

Requires marking material spec. on aaterials, inspection of<\\" plate (steel) and \\" nonferrous plate for deep dye stamping.

Requires inspection of materials during fabrication to detect* defects.

Requires inspection of dimensions and fit of attachaents.

Requires inspection at various stages of construction and prior to final closure and at hydro.

tfax. Allow. Press. Defines maximum allowable working UG-98 pressure.

Hydro Test UG-99 8418~1493743-BJ Defines requirements for hydro tests; sets limits for hydro pressure.

SURRY POWER STATION 1986 ASHE VIII Same as 1968 Code plus Inspector monitors manufacturer's Quality Control System.

Same as 1968 Code.

Revised to accept piece marking with grade type and class from spec.; lists inspections required if no piece marking.

Same as 1968 Code except deletes inspection for deep dye stamping.

Same as 1968 Code.

Revised to include all pressure-retaining parts and inspection of attachments for proper curvature before attaching to vessel.

Revised to require inspection inside vessel prior to final closure when conditions permit, external inspection at hydro and inspection of welds prior to application of lining's.

Same as 1968 Code.

Revised t~ allow waiver of post-hydro visual inspection of joints at 2/3 hydro pressure under certain conditions; recommends use of liquid relief valve under certain conditions.

COMMENTS Equivalent requirements. An additional responsibilitiy for the Inspector is specified.

Equivalent requirements 1986 Code more restrictive.

Additional inspections of materials to be welded required.

Equivalent requirements.

1986 Code does not require inspection of deep dye stamping.

Equivalent requirements 1986 Code more restrictive.

Dimensional check of all pressure-retaining parts is re~uired.

1968 Code only required head and ring sections.

1986 Code more restrictive.

External in-spection of vessel at time of hydro and pneumatic test required.

All welds inside vessel to be inspected prior to lining.

Equivalent requirements.

Equivalent requirements.

1986 Code includes a waiver of post-hydro visual in-spection if certain criteria as outlined in UG-99(g) are met.

e

COMPARISON OF 1968 TO 1986 ASHE CODE SECTION VIII DIVISION 1 SUBSECTION UG (GENERAL)

Page 7 of 8 SUBSECTION (1986 TITLES)

Pneumatic Test UG-100 1968 ASHE VI II Defines conditions under which pneuaatic test may be substi-tuted for UG-99 hydro and spe~ifies procedure.

Proof Tests for Guidelines for testing lllllterials for Max. Allow. Press. aaxiaua allowable working pressure.

UG-101 Test Gauges UG-102 NOT UG-103 General (Harking)

UG-115 Required Harking UG-116 Hethod of Harking UG-117 Stamping UG-118 Nameplates UG-119 Data Reports UG-120 Press. Relief Devices UG-125 8418-1493743-Bl Specifies acceptable test gauges.

Refers to Appendices for HP and LP tests.

General aarking requirements Specifies pressure vessel marking.

Specifieu method of aarking vessels.

Specifies staaping aetbod.

Specifies nameplates to be us.ed.

Addresses data sheets and partial data report.

General requirements to provide pressure relieving devices.

SURRY POWER STATION 1986 ASHE VI II Revised to allow waiver of visual inspection at 4/5 test pressure under certain conditions.

Same as 1968 Code.

Same as 1968 Code plus wore specific on gauge range.

Same as 1868 Code.

Expanded to include specific units of measurement.*

Basically the same as 1968 Code.

Updated to delete references to riveted and seamless construction and to add pressure welded.

Same as 1968 Code.

Same as 1968 Code.

Revised to be aore specific about methods of attaching.

Revised to include manufacturer's Quality Control System and expand instructions for Forms U-1, U-2, U-3.

Revised to address "non-reclosing pressure relief devices" instead of rupture discs.

COl1HENTS Equivalent requirements.

1986 Code in-cludes a waiver of inspection of vessel at 4/5 of required test pressure if certain criteria in UG-lOO(c) are met.

Equivalent requirements Equivalent requirements Equivalent requirements 1986 Code more restrictive.

Specific units of measurement are required to be used.

Equivalent requirements Equivalent requirements Equivalent requirements 1986 Code. is more restrictive.

It is expanded and requires nameplate to be attached according to UG-119(e).

  • 1986 Code more restrictive.

The data sheets require more exact information be provided.

Equivalent requirement e

J

SUBSECTION (1986 TITLES)

Press. Relief Valves UG-126 Liquid Relief Valves UG-128 Harking UG-129

  • Use of Code Stamp UG-130 Cert. of Press.

Relief Vlv. Cap.

UG-131 Detera. of Press.

Reliev. Requir.

UG-133 Press. Set of Press. Relief Devices UG-134 Installation UG-135 Hin. Req. for Relief Valves UG-136 COMPARISON OF 1968 TO 1986 ASHE.CODE SECTION VIII DIVISION SUBSECTION UG (GENERAL) 1968 ASHE VI II Specifies types of relief valves.

Specifies liquid relief valve ainiai1111 size.

Specifies ~arking for relief valves.

Restrictions for use of Code syabol staap.

Guidelines for certification of relief valve capacity.

Guidelines for-set pre_ssures of relief valves - partially aoved to UG-126 in 1986 Code and UG-132 in 1968 Code.

Guidelines for set pressures of relief valves.

Guidelines for installation of relief devices, listed uner UG-134 in 1968 Code.

Does not exist in 1968 Code *.

SURRY POWER STATION 1986 ASHE VIII Revised to change setting tolerances.

Same as 1968 Code.

Revised to include non-reclosing pressure relief devices.

Saae as 1968 Code.

Revised to allow for tests with water.

Revised to address pressure-relieving capacity, partially addressed in UG-131 in 1968 Code.

Same as 1968 Code UG-133.

Saae as 1968 Code UG-134.

Guidelines for mechanical, materials, inspection, testing of relief valves.

Page 8 of 8 COHHENTS 1986 Code more restrictive.

Specific set pressure tolerances for pressure relief valves are required.

Equivalent requirements Equivalent requirements Equiva,lent requirements Equivalent requirements.

Capacity certifi-cation test for pressure relief valve for noncompression fluids shall be conducted with water.

Equivalent requirement.

Information is now split up into different sections.

Equivalent requirements Equivalent requirements 1986 Code more restrictive.

This is a new section which institutes- _a l ~rger group of* minimum requirements.

8418-1493743-Bl e

APPENDIX C EVALUATION OF SUBSECTION UW (FABRICATION) 1968 VS 1986 ASME CODE SECTION VIII, DIVISION 1

COMPARISON OF 1968 TO 1986 ASHE CODE SECTION VIII DIVISION l SUBSECTION UW (FABRICATION)

Page I of 5 SUBSECTION (1986 TITLES)

Scope (Fabrication)

UW-1 Serv. Restrict UW-2 Weld Joint Cat.

UW-3 General (Hatl's)

UW-5 Gener~l (Design)

UW-8 Design of Weld Joints UW-9 Postweld Heat Treat UW-10 Radiographies &

Ultrasonic Exam.

UW-11 1968 ASHE VIII Applicability of Part UW Special restrictions for certain service.

Established welded joint categories.

General *aterial requireaents for pressure vessels.

General design applicability stateaent.

Specifies types of weld joints per*itted and plate thickness.

Refers to UW-40 for postweld heat treating procedure.

Specifies requirements for radio-graphic weld examination.

Joint Efficiencies Refers to Table UW-12 for joint UW-12 efficiencies to be used.

84JBA-1493743-Bl SURRY POWER STATION 1986 ASHE VIII Same as 1968 Code.

Same as 1968 Code except lethal substance service expanded.

Same as 1968 Code.

Revised to address pressure, nonpressure parts, and electroslag welding and friction welding processes.

Same as 1968 Code.

Section UW-9(c) Tapered Transitions revised.

Figure UW-9, Butt Welding of Plates of Unequal Thickness revised.

Tapered transition of 3 ti*es offset now allowed instead of *inimum of 4 times offset in 1968 Code.

Same as 1968 Code.

Revised to reference weld categories (A,B, C, etc) and allow ultrasonic examination under certain conditions.

Revised to provide exception for UW-ll(a) when applicable; addresses seamless vessel sections or heads.

COMMENTS Equivalent requirements Equivalent requirement~ section added to provide details for the radiographic examination of exchanger tubes and clari-fication of rules for shell-tube construction.

Equivalent requirements.

1986 Code more restrictive.

Pressure and nonpressure parts are now addressed separa-tely. Restrictions on type of material to be used with.different welding techniques apply.

Equivalent requirements 1986 Code more restrictive.

A transition of 3 times offset is required.

Restric-tions now apply if transition is provided by welding or grinding.

Equivalent requirements Equivalent requirements.

Ultrasonic exam-ination is now allowed for final closure seam under condition UW-ll.a(7).

1986 Code more restrictive.

Seamless vessel sections or heads are considered equivalent to welded parts.

e

SUBSECTION (1986 TITLES)

Attach. Details UW-13 Openings In or Adjacent to Welds UW-14 Weld Connections UW-15 Hin. Req. for Attach. at Weld Connections UW-16 Plug Welds UW-17 Fillet Welda UW-18 General (Fab.)

UW-26 Weld 'Processes UW-27 Weld Procedure Quality UW-28 8418A-1493743-Bl COMPARISON OF 1968 TO 1986 ASHE CODE SECTION VIII DIVISION l SUBSECTION UW (FABRICATION)

Page 2 of 5 1968 ASHE VI II Provides attachment details for vessel heads to shell.

Guidelines for openings in welded joints.

Guidelines for weld strength calculations.

Guidelines for location and mLnLaWD size of nozzle welds and other weld connections.

Guidelines for use of plug welds.

Guidelines for use of fillet welds.

General guidelines for fabrication.

Lists allowable welding processes.

Requires qualification of weld procedures.

SURRY POWER STATION 1986 ASHE VII I Revised to provide greater detail.

Saae as 1968 Code.

Revised to exeapt certain nozzle attachlllent welds in Figure UW-16.1 t°roa strength calculations.

Revised to provide greater detail.

Saae as 1968 Code.

Saae as 1968 Code.

Revised to include welders not employed by 11anufacturer and requirement for manufacturers.

Revised to include inertia and continuous drive friction welding, reference to Section IX definitions, arc, and resistance stud welding.

Revised to address welding nonpressure bearing attached to pressure parts, welding of test coupons.

COMMENTS 1986 Code more restrictive. Restrictions apply to tapered transition joints.

Longitudinal weld covered in more detail.

Equivalent requirements 1986 Code more restrictive. Figure UW-16.1 is more detailed in requirment to exempt nozzle attachments from stress calculations.

1986 Code more restrictive.

Code addresses aore attachment weld configurations with respect to joint type and weld size.

Equivalent requirements Equivalent requirements 1986 Code more restrictive.

Only welding qualified to Section IX allowed.

Guide-lines provided for welders not in the employ of the manufacturer.

Equivalent requirement.

1986 Code includes inertia and continuous drive friction welding.

Seciton IX referenced.

1986 Code more restrictive.

Code addresses qualification of nonpressure bearing attachments; 1968 Code does not address this.

e e

SUBSECTION (1986 TITLES)

Test of Welders

& Welding Operators UW-29 Lowest Weld Temperature UW-30 Cut, Fit, Alignment UW-31 Surface Cleaning for Welding UW-32 Align. Tolerance UW-33 Finish Long. &

Circ. Joints UW-35 Fillet Welds UW-36 Hise. Weld Req.

UW-37 Repair Weld Defects UW-38 8418A-1493743-Bl COMPARISON OF 1968 TO 1986 ASHE CODE SECTION VIII DIVISION l SUBSECTION UW (FABRICATION)

Page 3 of 5 1968 ASHE VI II Guidelines for qualification of welders.

Establishes low te11perature li11its for welding.

Guidelines for fitting and aligning parts prior to welding.

Guidelineo for cleaning surfaces prior to welding.

Specifies aligDlllent tolerances.

Finish details for butt weld joints and reinforcements.

Guidelines for fillet weld pene-tration.

Listi.ng of 11iscellaneous weld requirements.

Guidelines for repair of weld defects.

SURRY POWER STATION 1986 ASHE VIII Revised to be more specific with regard to welder testing, test coupons, reference QW-300 of Section IX.

Same as 1968 Code.

Revised to provide more detail on tack welds, intertia, and friction welding techniques.

Same as 1968 Code.

Revised to reflect joint categories.

Revised to provide greater detail with regard to aaterial thickness and joint types.

Revised address edge thickness reduction.

Expanded to include manufacturer's quality control system, inertia, and friction welding.

Same as 1968 Code except references "thermal gouging" instead of "oxygen grooving" to remove defects.

COMHENTS 1986 Code more restrictive.

Hore testing is required by the 1986 Code.

They include test for stud welding and non-pressure-bearing attachments.

Equivalent requirements 1986 Code more restrictive.

Tack welds procedure must be quali*fied with Section IX.

Detailed instruction for inertia and con-tinuous drive friction welding provided.

Equivalent requirements Equivalent requirements 1986 Code more restrictive.

Code covers a wider range of material thickness with respect to allowable reinforcement of the welds.

1986 Code more restrictive.

The shrink of the base metal due to welding at the edge of fillet weld must meet the re-quriements of Sec.tion UW-35(a)'.

Equivalent requirements expanded to include welder identification required for perma-nent nonpressure parts.

Equivalent requirements e

SUBSECTION (1986 TITLES)

Peening UW-39 Proc. for PWHT UW-40 Sect. Weld Joints UW-41

-Surf. W~ld Hetal Buildup UW-42 General (Insp. & Test)

UW-46 Check Weld Proc.

UW-47 Check Welder Qualifications UW-48 Check PWIIT Practice UW-49 Radiograph Exaa.

Welded Joints UW-51 8418A-1493743-Bl COMPARISON OF 1968 TO 1986 ASHE CODE SECTION VIII DIVISION 1 SUBSECTION UW (FABRICATION)

Page 4 of 5 1968 ASHE VIII Allows peening weld aetal.

Guidelines for postweld heat treating welds.

Addresses weld joint inspec.tion by sectioning.

This section does not exist in the 1986 Code.

General statement of applicability.

Requires use of qualified welding procedures.

Requires use of qualified welders.

Requires verification of postweld beat treataent.

Guidelines for radiographic examination of welds. welds.

SURRY POWER STATION 1986 ASHE VIII Same as 1968 Code.

Revised to address pressure parts of two different postweld number groups and provide number groups and provide more specific description of "nominal thickness."

Saae as 1968 Code.

Guidelines for weld metal buildup construction.

Saae as 1968 Code.

Same as 1968 Code.

Same as 1968 Code.

Same as 1968 Code.

Revised to reference ASHE V, Article 2, for radiographic examination of*welds.

COl1HENTS Equivalent requirements.

1986 Code more restrictive for welding materials of two different P-numbers.

PWHT shall be as specified in either UCS-56 or UHA-32.

Nominal thickness is defined in detail.

Equivalent requirements 1986 Code more restrictive.

Deposits of weld metal deposited to base metal must be performed under a qualified procedure and NDE performed.

Equivalent requirements Equivalent requirments Equivalent requirements Equivalent requirements 1986 Code more restrictive.

1986 Code references ASHE V, for radiographic requirements.

This section is more detailed for methods and requirements for radiographic examination.

e

SUBSECTION (1986 TITLES)

Spot Exam. of Welded Joints UW-52 Technique for Ultrasonic Exaa.

UW-53 General (Hark &

Reports)

UW-60 General (Press. Relief)

UW-65 8418A-1493743-B1 COMPARISON OF 1968 TO 1986 ASHE CODE SECTION VIII DIVISION 1 SUBSECTION UW (FABRICATION)

Page 5 of 5 1968 ASHE VIII Guidellnes for spot examination of welded joints.

This section does not exiat in the 1968 Code.

Refers to UG-115 through UG-120 for staaping and reports.

Refers to UG-125 through 134 for pressure relief devices.

SURRY POWER STATION 1986 ASHE VIII Same as 1968 Code plus includes external pressure vessels which were excluded from the 1968 Code.

Provides for ultrasonic examination of welds according to Appendix 12.

Same as 1968 Code.

Same as 1968 Code.

C01111ENTS 1986 Code more restrictive.

Includes external pressure vessel examination when required or permitted.

1986 Code more restrictive.

This section was not in the 68 Code.

Gives requirement for UT examination when required or per-aitted.

Equivalent requirments Equivalent requirements e