June 5, 1987 e

.A Mr. Thayer Cory Ms. Judy Zwelling **

Citizen Action for a Safe Environment 121 Oak Road Williamsburg, Virginia 23185

Dear Mr. Cory and Ms. Zwe ll ing:

We are responding to your Mailgram of December 11, 1986, as well asj.b.e..J)eti-tion you sent us on January 20, 1987.

You requested that NRC shu~down until all pipes have been fully inspected and a complete report on the December 9, 1986 accident has been issued publicly by Virginia Power.

Your request has been denied.

Reasons for the denial can be found in the Director's Decision enclosed with this letter.

In accordance with NRC regulation 10 CFR 2.206(c), the Commissioners can review the decision that permits the plant to continue to operate. Unless that decision is reviewed and subsequently reversed, it will become final action in 25 days and Surry will be permitted to continue to operate.

Also enclosed is a copy of the Notice of Issuance of Director's Decision that will be forwarded to the Office of the Federal Register for publication.

Enclosures:

1. Director's Decision 87-09
2.

Federal Register Notice cc w/enclosure: See next page Licensee DISTRIBUTION Docket File w/encl NRC PDR Local PDR EDO #2430 EDO Reading T. Murley/J. Sniezek F. Miraglia S. Varga G. Lainas L. Rubenstein D. Miller C. Patel

  • See previous
  • LA:PD22 DMi 11 er 5/ /87 concurrence
  • PM:PD22 CPatel:hc 5/ /87 Sincerely,
  • Original Signed *byi Thomas E. Murley Thomas E. Murley, Director Office of Nuclear Reactor Regulation V. Stello B. Clements, SECY, H-1149 OGG-Bethesda w/incoming (M. Malsch)

J. Lieberman, OGC ASLAB ASLBP ACRS ( 10)

J. Resner (2) (W-501)

D. Hagan PD22 Rdg.

D. Mossburg, PMAS (EDO #2430)

GPA/PA

  • D:PD22 LRubenstein
  • OGC 5/ /87

~ech Editor 6/ /87

~D:DRP 1bLainas 6/ /87 fD:DRP SVarga 6/ /87 Ao/JdR F~lia 6/~ /87 ~:k a~*181

~R TMu"I ey 6/) /87 I

~-

Mr. Thayer Cory Ms. Judy Zwelling e

Citizen Action for a Safe Environment 121 Oak Road Williamsburg, Virginia 23185

Dear Mr. Cory and Ms. 4welling:

\\

e We are responding to yoJr Mail gram of *December 11, 1986, as well as the peti-tion you sent us on January 20, 1987.

You requested th t NRC shut Surry down until all pipes have been\\fully inspected and a comple e report on the December 9, 1986, accident has been is~ued publicly by Virginia P,wer.

Your request has been denied.

Reasons for the de'nial can be found in the irector's Decision enclosed with this letter.

\\

In accordance with NRC regulation 10 CFR 2.206(c), the Commissioners can review the decision that permits the plant to continue t operate. Unless that decision is reviewed and subsequently re ersed, it will b come final action in 25 days and Surry will be permitted to conti ue to operate.

Also enclosed is a copy of the Not'ce of Issua e of Director's Decision that will be forwarded to the Office of he Federal Register for publication.

Enclosures:

1.

Director's Decision 87-

2.

Federal Register Notice cc w/enclosure: See next page Licensee DISTRIBUTION Docket File w/encl & incoming NRC PDR Local PDR EDO #2430 EDO Reading T. Murley/J. Sniezek F. Miraglia S. Varga G. Lainas L. Rubenstein D. Miller C. Pate 1

  • See previous
  • LA:PD22 DMi 11 er 5/ /87
  • D:DRP SVarga 6/ 1/87 concurrence
  • PM:PD22 CPatel :he 5/ /87 ADP:NRR FMiraglia 6/ /87
  • D:PD22 E. Murley, Director of Nuclear Reactor Regulation V. Ste l B. Cleme ts, SECY, H-1149 OGC-Bethe~da w/incoming J. Lieberm~n, OGC ASLAB

\\

ASLBP

'ACRS (10)

J. Resner (2) (W-501)

D. Hagan PD22 Rdg.

D. Mossburg, PMAS (EDO #2430)

GPA/PA

  • OGC
  • Tech Editor
  • AD:DRP LRubenstein Alt
  • GLainas 5/ /87 5/ /87 6/ 1/87 6/ 1/87 DD:NRR D:NRR CoY\\t'-"*n*-eol b~ plw"~

JSniezek TMurley PEPB 6/ /87 6/ /87 r-. l(c<'.N\\ t c"¥

Mr. Thayer Cory Ms. Judy Zwelling Citizen Action for a Safe Environment 121 Oak Road Williamsburg, Virginia 23185

Dear Mr. Cory and Ms. Zwelling:

We are responding to your Mailgram of December 11, 1986, as well as the peti-tion you sent us on January 20, 1987.

You requested that NRC shut Surry down until all pipes have been fully inspected and a complete report on the December 9, 1986, accident has been issued publicly by Virginia Power.

Your request has been denied.

Reasons for the denial can be found in the Director's Decision enclosed with this letter.

In accordance with NRC regulation 10 CFR 2.206(c), the Commissioners can review the decision that permits the plant to continue to operate. Unless that decision is reviewed and subsequently reversed, it will become fina}-*action in 25 days and Surry will be permitted to c_ontinue to operate.

/

Also enclosed is a copy of the Notice of Issuance of Dire~tor 1s Decision that will be forwarded to the Offic\\ of the Federal Registor/for publication.

Enclosures:

1. Director's Decision 87-
2. Federal Register. Notice cc w/enclosure:

See next page Licensee DISTRIBUTION Docket File w/encl & incoming NRC PDR Local PDR EDO #2430 EDD Reading T. Murley/J. Sniezek.

F. Miraglia S. Varga G. Lainas L. Rubenstein D. Miller

c. Patel
  • See previous
  • LA:PD22 DMjJler 5// / /87

~

concurrence

>'*PM: PD22 CPatel :he 5/!f/87 ADP:NRR FMiraglia 6/ /87 Sincerely, I

I

  • D :/PD22 LR~~enstein s1J'ir /87 DD:NRR JSniezek 6/ /87 Murley, Director Nuclear Reactor Regulation
  • OGC fftoufdhee7 5/&)/87 D:NRR TMurley 6/ /87 (W-501)

\\

  • fec~1 Ed_i tor

()~,;r' 61 I /81 A/2P G~as 6/ I /87

Mr. Thayer Cory Ms. Judy Zwelling Citizen Action for a Safe Environment 121 Oak Road Williamsburg, Virginia 23185

Dear Mr. Cory and Ms. Zwelling:

We are responding to your Mailgram of December 11, 1986, as well as the petition you sent us on January 20, 1987.

You requested that NRC shut Suf~y down until all pipes have been fully inspected and a complete report on t~e December 9, 1986, accident has been issued publicly by Virginia Power. i(our request has been denied. Reasons for the denial can be found in the/Director's Decision enclosed with this letter.

In accordance with NRC regulation 10 CFR 2.206(c), t~e ommissioners can review the decision that permits the plant to continue o operate. Unless that decision is reviewed and subsequently reversed, *twill become final action in 25 days and Surry will be permitted to con inue to operate.

Also enclosed is a copy of the Notice of Issuance~ Director's Decision which will be forwarded to the Office of the Federal Register for publication.

Enclosures:

1. Director's Decision 87-
2.

Federal Register Notice cc w/enclosure: See next page Licensee DISTRIBUTION Docket File w/encl & incoming NRC PDR Local PDR EDO #2430 EDO Reading

/

T. Murley/~l. Sniezek f F. Miraglia

s. Varga G. Lainas L. Rubenstein D. Miller
c. Patel I

I I

Since,rely, I

/

/

I I

/Thomas E. Murley, Di rector

/ Office of Nuclear Reactor Regulation V. Stello B. ~lements, SECY, H-1149 OGC-Bethesda w/incoming J. Lie~erman, OGC ASLAB

\\

ASLBP *. \\

ACRS (10) \\

J. Resner(~) (W-501)

D. Hagan

\\

PD22 Rdg.

D. Mossburg, PMAS (EDO #2430)

GM/M

\\

  • See previous
  • LA:PD22 DMiller concurrence
  • PM:PD22 CPatel:hc 5/ /87
  • D:PD22
  • OGC

\\

Tec~ditor AD:DRP 5/ /87 D:DRP SVarga 6/ /87 ADP:NRR FMf ragl i a 6/ /87 LRubenstein 5/ /87 DD:NRR JSniezek 6/ /87 av;;,

GLainas 5/ /87 6/ I /87 6/ /87 D:NRR TMurley 6/ /87

Mr. Thayer Cory Ms. Judy Zwelling Citizen Action for a Safe Environment 121 Oak Road Williamsburg, Virginia 23185

Dear Mr. Cory and Ms. Zwelling:

This is in response to your petition filed with the Nuclear Regu1atory Conmission on December 11, 1986, as supplemented January 20, 1987, pursuant to 10 CFR 2.206, requesting that certain actions be taken with respect tc the Surry Nuclear Power Station.

As explained in the enclosed Director's Decision, your request has been den!.

..1 A copy of this decision will be filed ~ith the Secretary for the c.;~sion 1s review in accordance with 10 CFR 2.206(c).

As provided in)(ltFR 2.206(c),

this decision will become final action o~\\ the Commissior1.,,fo 25 days, unless the Commission determines to review the d~sion w,Jn that time.

Also enclosed is a copy of the Notice of Iss~arn:e/of Director's Decision which will be forwarded to the Office of the Feder~*Register for publication.

Enclosures:

~

1. Director's Decision 87-

/

2.

Federal Register Notiie cc w/enclosure: ~

~t page Licensee DISTRIBUTION

~

Docket Fi'Tew/e cl & incoming NRC PDR Local PDR EDO #2430 EDO Reading T. Murley/

  • F. Miraglia S. Varga G. Lainas L. Rubenstein D. Miller C. Patel
  • See previous
  • LA:PD22 DMiller 5/ /87 ADP:NRR FMiraglia 5/ /87 concurrence
  • PM:PD22 CPatel:hc 5/ /87 DD:NRR JSniezek 5/ /87 Sillcere\\

Thomas E. Murley, Director Office of Nuc*lear Reactor Regulation

/

\\

\\

\\

\\

\\

V. Stello

~

B. Clements, SECY, H-1149 OGC-Bethesda w/incoming \\

J. Lieberman, OGC ASLAB

\\

~~:p(lO)

\\.

J. Resner (2) (W-501)

D. Hagan PD22 Rdg.

D. Mossburg, PMAS (EDD #2430)

GPA/PA

  • O:PD22 LRubenstein 5/ /87 AD:DRP Glainas 5/ /87 D:NRR TMurley 5/ /87 D:DRP SVarga 5/ /87

Mr. Thayer Cory Ms. Judy Zwelling e

Citizen Action for a Safe Environment 121 Oak Road Williamsburg, Virginia 23185 e

Dear Mr. Cory and Ms. Zwelling:

/\\

This is in response to your petition filed with the Nuclea~egulatory Commission on December 11, 1986, as supplemented January 20, 1987, pursuant to 10 CFR 2. 206, requesting that certain actions be tak<;rt with respect to the Surry Nuclear Power Station. As explained in the enclosed Director 1s Decision, your request has been granted in part and defiied in part.

A copy of this decision will be filed with the Secrlary for the Commission 1s review in accordance with 10 CFR 2.206(c).

As pr°;v'ided in 10 CFR 2.206(c),

this decision will become final action of the Commission in 25 days, unless the Commission determines to review the decisi1within that time.

Also enclosed is a copy of the Notice of Issuance of Director 1s Decision which will be forwarded to the Office of the Federal Register for publication.

Sincerely, I

.1 Thomas E. Murley, Di rector

-~

// Office of Nuclear Reactor Regulation

Enclosures:

1. Director 1s Decision 7-

//

2. Federal Reaister Notite cc w/enclosure:

See next p~~/

Licensee DISTRIBUTION

~

Docket Fi le w/encl & incomi-hg

, V. Stello NRC PDR

/

'R~ Clements, SECY, H-1149 Local PDR I

OG~Bethesda w/incoming EDO #2430

/

'-1. L i-eberman, OGC EDO Reading 1

1 A SLAB ~

T. Murley/J. Sniezek I ASLBP

~

F. Miraglia

\\/

ACRS (10) '-

S. Varga J. Resner (2) (W-501)

G. Lainas D. Hagan L. Rubenstein PD22 Rdg.

D. Miller D. Mossburg, PMAS (EDO #2430)

C. Patel

~-.

GPA/PA L~2 r?:fo22 OGC D

  • CPatel:hc LRuben~tein 5 \\ /8~

5//i//87 5/l~/87 5/ /87 ADP:NRR FMiraalia 5/ /87 OD:NRR JSniezek 5/ /87 D:NRR TMurley 5/ /87

\\

\\AD:DRP GLainas 5\\ /87 D:DRP SVarga 5/ /87

e Mr. W. L. Stewart Virginia Electric and Power Company cc:

Mr. Michael W. Maupin Hunton and Williams Post Office Box 1535 Richmond, Virginia 23213 Mr. Robert F. Saunders, Manager Surry Power Station Post Office Box 315 Surry, Virginia 23883 Resident Inspector Surry Power Station U.S. Nuclear Regulatory Co1T1Dission Post Office Box 166, Route 1 Surry, Virginia 23883 Mr. Sherlock Holmes, Chainnan Board of Supervisors of Surry County Surry County Courthouse Surry, Virginia 23683 W. T. Lough Virginia Corporation Commission Division of Energy Regulation Post Office Box 1197 Richmond, Virginia 23209 Mr. J. T. Rhodes Senior Vice President - Power Ops.

Virginia Electric and Power Company Post Office Box 26666 Richmond, Virginia 23261 Regional Administrator, Region II U.S. Nuclear Regulatory ColTITiission 101 Marietta Street, Suite 3100 Atlanta, Georgia 30323 James B. Kenley, M.D., ColTITiissioner Department of Health 109 Governor Street Richmond, Virginia 23219 e

Surry Power Station Attorney General Supreme Court Building 101 North 8th Street Richmond, Virginia 23219